Maintenance
(Keep your Vax as good as new)
WARNING: To reduce the risk of electric shock, the power cord must be disconnected
before performing maintenance/troubleshooting checks. Turn the vacuum cleaner off and
unplug from the electrical socket
!
Hose blockages
The flexible hose may be disconnected
from the vacuum cleaner. Carefully remove
any blockages found and reconnect the
hose securely.
Lay the Turbobrush floor head on a flat surface and turn over to
expose the brushbar. Using a pair of scissors, cut through any
threads or hairs caught by the brushbar that have wrapped
around the guides
Accessory blockages
Remove accessory from the hose/telescopic
tube. Carefully remove the blockage and
return to the cleaner.
Removing blockages from the TurboTool
(some models only)
Locking ring
Tabs
Turn the TurboTool over and
slide off the locking ring.
Removing blockages from the Turbobrush
(some models only)
Pivot lowering housing and
remove clog.
To re-assemble, be sure that
the tabs are engaged. Pivot
the lower housing closed. Slip
the locking ring into the
groove at the neck of the
TurboTool to complete
reassembly.
Clearing blockages