Vds AMICO 400DG Technical installation manual

Summary of AMICO 400DG

  • Page 1

    Irreversible operator for swing gates and doors warning!! Before installing, thoroughly read this manual that is an integral part of the pack the ce mark conforms to european directive eec 89/336 + 92/31 + 93/68 d.L. 04/12/1992 n. 476. Our products if installed by qualified personnel capable to eval...

  • Page 2

    Packing contents ............................................................................. 2 view of typical automation and names of components ............. 3 technical data .................................................................................... 3 dimensions ..........................

  • Page 3

    Max. Weight of gate 250 kg max. Width of gate 2,50 mt motors power supply 24vdc 230 vac motor power 50 w 200 w motor rpm 1800 1400 condenser / 12,5 µf mechanical unlock for emergency manoeuvre with key working temperature -20° c / +55° c weight 8.5 kg protection rating ip 55 opening time 90° 20 sec ...

  • Page 4: Dimensions

    Dimensions typical connection and cable section 2x1,5mm2 (24 vdc ) 4x1,5mm2 (230 vca ) 2x0,75mm2 4x0,75mm2 4x0,75mm2 2x0,75mm2 105 mm 825 mm 1 1 0 m m 400 mm 3x1,5mm2 230v line rx photocell tx photocell.

  • Page 5: Installation

    Installation considerations for installation a b a b c d opening angle a b cu 90 80 80 160 90 90 180 100 100 200 100 150 250 100 110 110 220 120 120 240 120 100 220 opening angle a b cu 110 130 130 260 140 140 280 150 150 300 90° con corsa diponibile 400mm 160 160 320 175 175 350 190 190 380 200 200...

  • Page 6

    Warning! When establishing the height off the ground at which to fasten the plate (a) (fig.1) onto the post, keep in mind the height at which the plate will be fastened for anchoring the piston to the gate and that the plate (b) must be fastened 40 mm below that on the post to obtain horizontal leve...

  • Page 7: Troubleshooting

    Troubleshooting problem probable cause solution on giving a command with the remote control or with the key-switch, the gate doesn’t open or the motor doesn’t start 230 volt mains voltage absent check master switch emergency stop present check for any stop selectors or commands. If not used, check j...

  • Page 8

    R e v . 2 -0 5 /1 3 in g safety precautions these warnings are an essential, integral part of the product and must be given to the user. They provide important indications on the installation, use and maintenance and must be read carefully. This form must be preserved and passed on to subsequent use...