Vds UNDER 250 Technical Installation Manual

Summary of UNDER 250

  • Page 1

    T echnical i nstallation m anual underground operator for swinging gates and doors warning!! Before installing, thoroughly read this manual that is an integral part of the pack the ce mark conforms to european directive eec 89/336 + 92/31 + 93/68 under 250

  • Page 2: Index

    2 index 1 packing contents ............................................................3 2 view of typical automation and names of components ........................................................................4 3 technical data ..................................................................5...

  • Page 3

    3 1 packing contents this kit contains the following items: 1 underground operator 1 foundation box 1 lever kit for 90° opening 1 release lever optional accessories 1 remote control 1 tuned antenna 433.920 1 pair of outdoor photocells 1 flashing light 230v 1 outdoor key-switch 1 sign chs.

  • Page 4

    4 2 view of typical automation and names of components optimal installation 1. Operators 2. Electronic control unit 3. External photocell internal photocell (optional) 4. Flashing warning light 5. Key-switch 6. Antenna 7. Remote control.

  • Page 5

    5 3 technical data under 250 (230vac) max. Weight per wing 500 kg max. Width per wing 2,5 m motors power supply 230 v ± 10%, 50 hz condenser 10 µ f motor current input 1.2 – 1.6 a motor power 200w overload cutout 135°c torque given 250 nm operator weight 10 kg noise level protection rating ip 67 ope...

  • Page 6

    6 4 dimensions 5 typical connection and cable section 2 x 0.75 mm2 rx photocell tx photocell 3 x 1.5 mm2 4 x 0.75 mm2 2 x 0.75 mm2 4 x 1.5 mm2 4 x 1.5 mm2 230v line.

  • Page 7

    7 considerations for installation • the installation and testing operations must be performed solely by qualified personnel in order to guarantee the proper and safe operation of the automatic gate. • the company declines any responsibility for damage caused by incorrect installations due to incompe...

  • Page 8

    8 6.2 box installation procedure 6.2.1 dig a hole big enough to hold the box containing the operator (see f1) 6.2.2 insert the tubes for water drainage in the prepared holes (f1c) 6.2.3 insert the sheath for laying the power cables and limit switch (f1d). Note: while positioning the box, keep in min...

  • Page 9

    9 6.3 assembling the operator and levers 6.3.1 place the operator in the box and fasten it with the nuts provided. 6.3.2 insert the ball in the pin located on the box and fit the gate anchorage lever (l1) 6.3.3 insert the lever (l3) onto the motor shaft 6.3.4 fit the connecting lever (l2) f3 f4 f5.

  • Page 10

    10 6.4 fastening the operator lever to the gate 6.4.1 insert the cover and fasten it with the screws provided view 6.4.2 position the gate wing and the lever (l1) so that they are perfectly aligned and fasten them by welding or similar. 6.5 emergency release procedure • insert the key chs provided i...

  • Page 11

    11 7 troubleshooting problem probable cause remedy 230 volt mains voltage absent check master switch emergency stop present check for any stp selectors or commands. If not used, check jumper on stp contact input on unit fuse blown replace with one of same value. Power cable of motor or motors not co...

  • Page 12

    Safety precautions these warnings are an essential, integral part of the product and must be given to the user. They provide important indications on the installation, use and maintenance and must be read carefully. This form must be preserved and passed on to subsequent users of the system. The inc...

  • Page 13: Www.Kaputnyitunk.Hu

    1095 budapest, mester u. 34. Tel.: *218-5542, 215-9771, 215-7550, 216-7017, 216-7018 fax: 218-5542 mobil: 30 940-1970, 20 949-2688 1141 budapest, fogarasi út 77. Tel.: *220-7940, 220-7814, 220-7959, 220-8881, 364-3428 fax: 220-7940 e-mail: delton@delton.Hu web: www.Delton.Hu www.Kaputnyitunk.Hu mobi...