MAINTENANCE AND CLEANING
Disconnect the mains electrical supply by means of the double pole switch.
Remove the front grille as described above and wash with a mild detergent.
To clean the inside of the fan , use a soft brush taking care not to cause any damage to the electrical wiring.
??
The connection between the fan and the mains supply must be
carried out by means of a safety and insulating trasformer with
the appropiate power.
??
The transformer should be connected to the mains supply via a
double pole safety switch with at least 3mm contact opening.
??
The fan MUST be used with transformer provided.
??
The trasformer must be installed outside zone 1 and 2; if it is
installed in zone 3, it should be mounted with the cable entrance
turned dow nwards.
??
The transformer must be installed as close as possible to the
fan.
??
The cable to be used to connect the transformer with the fan
must be class II, with a section area of at least 1,5 mm and a
maximum length not longer than 10 m.
N.B. Fans with timer or humidistat MUST be connected only with
the transformers provided for these versions.
For the connections to be carried out between the main supply , the
transformer and the fan, please refer to the following diagrams.
LOW VOLTAGE MODELS
WIRING INSTRUCTIONS
The SELV (Safety Extra Low Voltage) models work at low voltage (12 volts); due to this feature, the SELV models may be installed in zones 1 as well
as zone 2 of the bathroom (see enclosed drawing).
For the installation and assembly, please refer to the warnings listed below.
MF 100 T - MF 250 T
MF 100 HCT - MF 250 HCT
ATTENTION
To wire the HCT version with a remote switch
make sure the pull cord switch is OFF
and cut off the pull cord.
MF 100 C
Lamp
MF 100 - MF 250
Double Pole Remote Switch
MF 250 H2R
WITH INTEGRAL PULL CORD
WITH REMOTE
SWITCH
A FULL RANGE OF ACCESSORIES ARE AVAILABLE WITH THIS RANGE, INCLUDING
M F 1 0 0 2 R L V
Lamp
Lamp
MF 100 2C - MF 250 2C
MF 100 H2C - MF 250 H2C