Vector MAXX SST 3000 VEC051 Owner's manual - page 14
11
APPLIANCE
AMPS@110VAC
WATTS@110VAC
LAPTOP COMPUTER
0.5
55
HOUSEHOLD POWER MIXER
2
240
240-WATT STEREO/AMPLIFIER
2.2
265
REFRIGERATOR
3
360
3/8” VARIABLE SPEED DRILL
3
360
VARIABLE SPEED JIG SAW
3
360
10-SPEED BLENDER
3.2
375
BELT SANDER
3.4
410
3/8” REVERSIBLE DRILL
3.5
420
HOUSEHOLD FOOD PROCESSOR
3.6
430
COMPUTER AND MONITOR
4
450
PORTABLE VACUUM
4.6
540
8-CUP COFFEE MAKER
5.5
650
ELECTRIC TRIMMER
5.5
660
1/2” HAMMER-DRILL
5.5
660
RECIPROCATING SAW
6
720
VACUUM CLEANER
7.2
865
1-1/8” ROTARY HAMMER
7.8
940
1/6 H.P. SUBMERSIBLE SUMP PUMP
8
960
COMPACT MICROWAVE OVEN
8.5
1020
2-SLICE TOASTER
8.8
1050
HEAVY-DUTY WORKLIGHT
9
1080
14” CHAIN SAW
10
1200
42” FAN
10.3
1235
200 MPH BLOWER/VAC
12
1440
16” CHAIN SAW
12
1440
WET-DRY VAC, 6 H.P., 16 GALLONS
12
1440
10” BENCH SAW
13
1560
FULL-SIZE MICROWAVE OVEN
14.5
1750
12” COMPOUND MITER SAW
15
1800
12-1/2” PORTABLE PLANER
15
1800
HEAVY-DUTY 7-1/4” CIRCULAR SAW
15
1800
14” CHOP SAW
15
1800
NOTE:
APPLIANCE SPECIFICATIONS MAY VARY FROM BRAND TO BRAND. THIS TABLE IS OFFERED
ONLY AS A GUIDE TO APPROXIMATE POWER RATINGS. CHECK APPLIANCE MANUALS OR
PRODUCT LABELING FOR ACTUAL RATINGS.
16
Low Battery Alarm:
An audible alarm will sound when:
1. The 12 VDC power supply voltage drops down to 10.6 volts. This indicates
that the power source (battery) needs to be recharged, or there is an excessive
voltage drop between the battery power source and the inverter.
2. The inverter is overloaded.
3. The inverter is in thermal shutdown.
NOTE:
It is normal for the alarm to sound when the
MAXX
SST
™
3000
is being
connected to, or disconnected from, a 12 VDC power source. This does
NOT indicate a problem. However, if this alarm is heard, except as
described, discontinue inverter operation and recharge the battery before
further use. If the voltage drops to 10.0 VDC, the inverter will automatically
shut down. The inverter will automatically restart when the input voltage
increases.
If the low voltage alarm sounds when the battery power source is fully charged,
refer to the troubleshooting table for possible causes and remedies.
4.4.4 Circuit Protection
The inverter has electronic circuit protection. The two front panel mounted 15 amp circuit
breakers can be manually reset in the event they trip due to an overload or short circuit
condition. If the High Output Terminal Block is used, a user-supplied dual ganged
30 ampere circuit breaker MUST be wired to protect the external wiring and
devices connected to it.
WARNING
The inverter is an industrial grade, heavy duty device that generates high voltage.
The front-panel mounted circuit breakers handle any overload situations by dis-
connecting AC output to prevent potential damage to the inverter and/or any
equipment that it is powering. If re-setting the front-panel mounted circuit breakers
or the external mounted hardwire circuit breaker does not cure a problem, DO
NOT ATTEMPT TO OPEN THE INVERTER. Opening the inverter, for any reason,
will void the warranty. The unit must be returned to Vector Manufacturing, Ltd. for
testing and repair by professional factory technicians.