Vector MAXX SST VEC049C Owner's Manual

Manual is about: COMPACT POWER INVERTERS

Summary of MAXX SST VEC049C

  • Page 1

    4140 s.W. 28th way • ft. Lauderdale, fl 33312 tel 954.584.4446 • fax 954.584.5556 toll-free: (866) 584-5504 owner’s manual this manual contains important information regarding safety, operation, maintenance and storage of this product. To avoid possible injury or property damage, please read this in...

  • Page 2: Important Safety Information

    Important safety information to ensure reliable service, your power inverter must be installed and used properly. Please read the installation and operating instructions thoroughly prior to installation and use. Pay particular attention to the warning and caution statements in this manual. The cauti...

  • Page 3: Contents

    Contents 1.0 introduction 1.0 basic tour of inverter . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.1 front panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.2 back panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.2 maxx sst safet...

  • Page 4: 1.0   Introduction

    1.0 introduction your new vector maxx sst inverter is one in a series of the most advanced dc to ac inverters available. With proper care and appropriate usage, it will provide years of dependable service in your car, truck, rv or boat. The maxx sst supplies continuous power and peak watts, in the f...

  • Page 5

    Figure 1 – front panel figure 2 – back panel 5 1 3 2 1 3 4 2 5 1) three north american standard outlets 2) green led shows unit is operating 3) red led shows unit is shut down 4) on/off switch 4 1.2 maxx sst safety features built-in automatic safety features include: • overload and over-temperature ...

  • Page 6: 1.3 Appliance Cautions

    Maxx sst™ inverters are ideal for powering: • tv/vcr combinations • refrigerator/freezers • lights • radio receivers/transceivers • heavy duty power tools & chargers • stereo systems • small microwave ovens • household appliances • computers and peripheral equipment • dry and/or wet-and-dry vacuums ...

  • Page 7: 2.0  Inverter Applications

    2.0 inverter applications aside from issues of supplying power to higher wattage appliances, inverters must be supplied with a constant source of high current 12vdc from a bank of batteries. At full watt load, the dc input requirements are up to 15 amps at 12vdc. Read and comply with the following a...

  • Page 8: 3.0  Theory of Operation

    3.0 theory of operation maxx sst™ inverters change 12vdc into 110/120vac rms, electrical power. This is accomplished in two steps. (see figure 4). The first stage raises the 12vdc input to 145vdc. The advanced design of the dc-to-dc first stage uses high-frequency conversion techniques that replace ...

  • Page 9: 4.0  Operation

    Note: because of wave-shape differences, using standard digital or analog voltmeters may not correctly read the inverter output voltage. Unless a true rms voltmeter such as a "fluke 87", "fluke 8060a", "beckman 4410" or "triplet 4200" is used, the reading will be from 2 to 20 volts low. 4.0 operatio...

  • Page 10

    Appliance amps@ watts@ 110/120vac 110/120vac computer and monitor 4 440 portable vacuum 4.6 506 8-cup coffee maker 5.5 605 electric trimmer 5.5 605 1/2" hammer-drill 5.5 605 reciprocating saw 6 660 vacuum cleaner 7.2 792 1-1/8" rotary hammer 7.8 858 1/6 h.P. Submersible sump pump 8 880 compact micro...

  • Page 11

    Inductive loads, such as tvs and stereos, require more current to operate than do resistive loads with the same wattage rating. Induction motors, as well as some tvs, may require two to six times their rated wattage to start up. Because the maxx sst™ inverters have a peak watt power rating, many suc...

  • Page 12

    Figure 6 – battery operating time for example, as shown in figure 6, using a 400 amp hour battery (batteries), if the average power usage will be 1000 watts, the operating time will be about 150 minutes. A larger capacity battery will deliver more operating time between recharges. Note: the manufact...

  • Page 13: 5.0  Installation

    5.0 installation maxx sst™ inverters will provide you with various watts of continuous, electrical power (see models specification chart page 18) when powered by a 12vdc source such as is found in a vehicle or multiple battery configuration as shown in figure 7. This manual does not describe all of ...

  • Page 14

    In all marine applications, do not install the inverter below or near the waterline, and keep the inverter away from moisture and water. Use only non-corrosive marine fasteners and fittings for installation. Only con- nect the inverter’s dc input to existing wiring (which must be approved for marine...

  • Page 15

    5.4 quick operational checkout or emergency use you will need: • one heavy-duty jumper cable set with specified awd wire rating (see page 18) • one fully-charged automobile battery • a common, slip joint pliers for loosening and tightening terminal nuts test procedure: 1. Remove the plastic terminal...

  • Page 16

    Preliminary installation notes: the inverter has four slots in its mounting bracket that allow the unit to be fastened against a bulkhead, floor, wall or other flat surface. Ideally, the mounting surface should be cool to the touch. It is more electrically efficient to use longer ac wiring than dc w...

  • Page 17

    9. Crimp or clamp on a heavy-duty, battery-connection terminal to the other end of the negative (–) and positive (+) cable. Connect the negative (–) bat- tery terminal cable to the negative (–) battery terminal connector. 10. Ensure the inverter power switch is in the off position (see figure 1 ). 1...

  • Page 18: 6.0  Specifica

    18 maximum continuous power 1000 w a tts 1200 w a tts 1500 w a tts 2000 w a tts 2500 w a tt surge capacity (peak power) 2000 w a tts 2400 w a tts 3000 w a tts 4000 w a tts 5000 w a tts no load current draw (switch on) 0.6 amps 1.3 amps 1.3 amps 1.3 amps 1.8 amps max. Efficiency approximately 90% 90%...

  • Page 19: 7.0  Service & Parts

    7.0 service & parts for service on the inverters, contact the technical support department at: vector manufacturing, ltd 4140 s.W. 28th way • ft. Lauderdale, florida 33312 tel. (954) 584-4446 • fax (954) 584-5556 • toll-free: (866) 584-5504 8.0 troubleshooting 8.1 common problems: power tools and mi...

  • Page 20: 9.0   Maintenance

    8.2 troubleshooting guide trouble/ indication possible cause suggested remedy no ac output – dc input below recharge or replace red led lit 10 volts battery no ac output – excessive appliance reduce load-wait for red led lit load-thermal shutdown inverter to cool. Turn off low battery alarm bad conn...

  • Page 21: 10. Warranty

    10. Warranty vector 2 year limited warranty program this limited warranty program is the only one that applies to this product, and it sets forth all the responsibilities of vector manufacturing, ltd., regarding this product. There is no other warranty other than those described herein. This vector ...