Vector TCY-BH User Manual

Summary of TCY-BH

  • Page 1

    Humidistat tcy-bh doc: 70-00-0142, v1.4, 20160912 © vector controls gmbh, switzerland page 1 subject to alteration www.Vectorcontrols.Com tcy-bh humidistat features control for binary humidifiers and dehumidifiers with or without fan support. Low power energy consumption: relays switching for output...

  • Page 2

    Humidistat tcy-bh doc: 70-00-0142, v1.4, 20160912 © vector controls gmbh, switzerland page 2 subject to alteration www.Vectorcontrols.Com technical specification important notice and safety advice this device is for use as operating controls. It is not a safety device! Where a device failure endange...

  • Page 3

    Humidistat tcy-bh doc: 70-00-0142, v1.4, 20160912 © vector controls gmbh, switzerland page 3 subject to alteration www.Vectorcontrols.Com dimensions mm (inch) connection diagram description: connections depend on parameter cp10 and cp11! (see page 10) cp10 do1 do2 rt cp10 = 0 humidify dehumidify tem...

  • Page 4

    Humidistat tcy-bh doc: 70-00-0142, v1.4, 20160912 © vector controls gmbh, switzerland page 4 subject to alteration www.Vectorcontrols.Com display and operation operation mode and state indication comfort (occupied) all control functions operating per set points. Economy (unoccupied): set points shif...

  • Page 5

    Humidistat tcy-bh doc: 70-00-0142, v1.4, 20160912 © vector controls gmbh, switzerland page 5 subject to alteration www.Vectorcontrols.Com advanced user setup menu to enter the advanced user setup menu, activate the controller by pressing the power button. Press the enter key for 3 sec until sel is s...

  • Page 6

    Humidistat tcy-bh doc: 70-00-0142, v1.4, 20160912 © vector controls gmbh, switzerland page 6 subject to alteration www.Vectorcontrols.Com configuration parameters the tcy-bh is preset to work for most applications. For special requirements it can be fine-tuned to work ideally with a simple parameter...

  • Page 7

    Humidistat tcy-bh doc: 70-00-0142, v1.4, 20160912 © vector controls gmbh, switzerland page 7 subject to alteration www.Vectorcontrols.Com control functions (code 241) warning! Only experts should change these settings! See user parameters for login procedure. Parameter description range standard cp ...

  • Page 8

    Humidistat tcy-bh doc: 70-00-0142, v1.4, 20160912 © vector controls gmbh, switzerland page 8 subject to alteration www.Vectorcontrols.Com input configuration cp 14 off = temperature setback is disabled on = temperature setback is enabled on, off off cp 15 set point limit at full setback 0…100% 20% c...