Summary of TCY-MT-U

  • Page 1

    Tcy-mt-u pi-temperature controller doc: 70-00-0176 v1.2, 20160114 © vector controls gmbh, switzerland page 1 subject to alteration www.Vectorcontrols.Com tcy-mt-u series pi-temperature controller features temperature pi control for hvac systems. Up to 2 modulating outputs for dc 0–10v with 10mv reso...

  • Page 2

    Tcy-mt-u technical specifications doc: 70-00-0176 v1.2, 20160114 © vector controls gmbh, switzerland page 2 subject to alteration www.Vectorcontrols.Com technical specifications power supply operating voltage 24 v ac/dc ± 10 %, 50/60 hz, class 2 48va max power consumption max. 1.5 va electrical conn...

  • Page 3

    Tcy-mt-u technical specifications doc: 70-00-0176 v1.2, 20160114 © vector controls gmbh, switzerland page 3 subject to alteration www.Vectorcontrols.Com installation and safety advice caution! This device is intended to be used for comfort applications. Where a device failure endangers human life an...

  • Page 4

    Tcy-mt-u operation instructions doc: 70-00-0176 v1.2, 20160114 © vector controls gmbh, switzerland page 4 subject to alteration www.Vectorcontrols.Com display and operation operation mode comfort (occupied) all control functions operating per set points. Economy (unoccupied): set points shifted acco...

  • Page 5

    Tcy-mt-u operation instructions doc: 70-00-0176 v1.2, 20160114 © vector controls gmbh, switzerland page 5 subject to alteration www.Vectorcontrols.Com configuration parameters for firmware version 1.2 the tcy-mt-u is preset to work for most applications. For special requirements it can be fine-tuned...

  • Page 6

    Tcy-mt-u configuration doc: 70-00-0176 v1.2, 20160114 © vector controls gmbh, switzerland page 6 subject to alteration www.Vectorcontrols.Com control functions (password 241) warning! Only experts should change these settings! See user parameters for login procedure. Control configuration parameter ...

  • Page 7

    Tcy-mt-u configuration doc: 70-00-0176 v1.2, 20160114 © vector controls gmbh, switzerland page 7 subject to alteration www.Vectorcontrols.Com t [°c, f] u [v, ma] heating cooling 10 0 50 0 y h1 , y r1 w h x dz y c1, y d1 w c max heating: cp14 min cooling: cp15 max cooling: cp16 min heating: cp13 outp...

  • Page 8

    Tcy-mt-u configuration doc: 70-00-0176 v1.2, 20160114 © vector controls gmbh, switzerland page 8 subject to alteration www.Vectorcontrols.Com input configuration parameter description range default cp 18 configuration of remote input (x1) 0 = control input 1 = comfort/economy mode switch 2 = comfort...