Vector TLC3-FCR-2 Engineering Manual

Summary of TLC3-FCR-2

  • Page 1

    Tlc3-fcr-2 engineering manual doc: 70-00-0202, v3.0 date: 20111027 © vector controls gmbh, switzerland page 1 subject to alteration tlc3-fcr-2 intelligent fan coil controller features • the pwm and 3-point floating control option reduces room temperature fluctuations and energy consumption • low pow...

  • Page 2

    Tlc3-fcr-2 engineering manual doc: 70-00-0202, v3.0 date: 20111027 © vector controls gmbh, switzerland page 2 subject to alteration technical specification power supply operating voltage -24 -230 ac voltage: 50/60hz 22-26v ac/dc 210–250 vac power consumption max 1w, 1.5 va electrical connection term...

  • Page 3

    Tlc3-fcr-2 engineering manual doc: 70-00-0202, v3.0 date: 20111027 © vector controls gmbh, switzerland page 3 subject to alteration mounting location • install the controller on an easy accessible interior wall, approx. 1.5 m above the floor in an area of average temperature. • avoid direct sunlight...

  • Page 4

    Tlc3-fcr-2 engineering manual doc: 70-00-0202, v3.0 date: 20111027 © vector controls gmbh, switzerland page 4 subject to alteration display and operation operation mode comfort (occupied) all control functions operating per set points. Economy (unoccupied): set points shifted according to parameters...

  • Page 5

    Tlc3-fcr-2 engineering manual doc: 70-00-0202, v3.0 date: 20111027 © vector controls gmbh, switzerland page 5 subject to alteration manual heat – cool change to manually change heating or cooling mode press the option key for more than 2 seconds. Access to manual heat – cool change may be disabled b...

  • Page 6

    Tlc3-fcr-2 engineering manual doc: 70-00-0202, v3.0 date: 20111027 © vector controls gmbh, switzerland page 6 subject to alteration operation with opr-1 the deluxe version may be alternatively operated with an infrared remote controller. 1. Mode indication, auto, dry, cool, fan, heat 2. 2-digit disp...

  • Page 7

    Tlc3-fcr-2 engineering manual doc: 70-00-0202, v3.0 date: 20111027 © vector controls gmbh, switzerland page 7 subject to alteration setting of user parameters the tlc3-fcr-2 is an intelligent controller and can be adapted to fit perfectly into your fan coil application. The control operation is defi...

  • Page 8

    Tlc3-fcr-2 engineering manual doc: 70-00-0202, v3.0 date: 20111027 © vector controls gmbh, switzerland page 8 subject to alteration control configuration identifying the firmware version the parameters and functionality of controller depend on its firmware revision. It is therefore important to use ...

  • Page 9

    Tlc3-fcr-2 engineering manual doc: 70-00-0202, v3.0 date: 20111027 © vector controls gmbh, switzerland page 9 subject to alteration control configuration for pwm – 3-point floating mode fc 14 p – band heating x ph 0-10.0°c (20.0°f) 2.0°c (4.0°f) fc 15 p – band cooling x pc 0-10.0°c (20.0°f) 2.0°c (4...

  • Page 10

    Tlc3-fcr-2 engineering manual doc: 70-00-0202, v3.0 date: 20111027 © vector controls gmbh, switzerland page 10 subject to alteration notes:.