Vega ASV-1 Operating Manual

Summary of ASV-1

  • Page 1

    Introduction the asv-1 is a 2 1/4” sunlight readable encoding altimeter, airspeed and wide range vertical speed indicator. The altimeter contains an internal high accuracy 24 bit digital altitude sensor which calculates altitude from -1000 ft up to a maximum of 35000 ft. The asv-1 outputs various fo...

  • Page 2: 1 Features

    Vega asv-1 operating manual page 2 1 features • large 1.8” high resolution 160x128, sunlight readable, wide viewing angle, 1000 cd/m2 tft lcd display • an internal high accuracy 24 bit digital altitude sensor calculates altitude from –1000 ft up to a maximum of 35000 ft (-304m to 10668m) • the asv-1...

  • Page 3: 2 Asv-1 Layout

    Vega asv-1 operating manual page 3 2 asv-1 layout 3 main display f2 / down button: menu system: softkey button normal display: press to view the timers and max values display sunlight readable color graphic display: backlight can be adjusted in the menu system rotary control (up/down) & enter button...

  • Page 4

    Vega asv-1 operating manual page 4 3.1 maximum airspeed display this display can be accessed by pressing the f2/down button during the normal display mode. Press the f1/up button when the max values display is showing to reset the maximum values to the current airspeed. 3.2 start / stop flight displ...

  • Page 5: 4 Menu System

    Vega asv-1 operating manual page 5 4 menu system press the rotary control button during the normal display mode to enter the menu system. Use the rotary control to navigate through the menu system. 4.1 exiting the menu system press the f1/up button to exit the menu system when the “exit” soft key is...

  • Page 6

    Vega asv-1 operating manual page 6 altitude unit: select if you want the altitude displayed in ft (feet) or m (meters). Pressure unit: select if you want the local pressure displayed in mb (millibars) or “hg (inches of mercury). Resolution: select the resolution of the altitude value, a selection of...

  • Page 7

    Vega asv-1 operating manual page 7 millibars,+/-, four digit vsi reading right justified zero padded in ft/min, x, checksum, carriage return the checksum is a simple modulo 256 sum of the binary values of the individual characters. The checksum is sent as two characters in hexadecimal format microai...

  • Page 8

    Vega asv-1 operating manual page 8 4.3 vsi setup (vertical speed indicator setup) vsi display: select if you want the vsi display to be shown on the altitude “tape” display. The vsi display is always shown on the altitude “classic” display. Vsi unit: select if you want the vsi to be displayed in "ft...

  • Page 9

    Vega asv-1 operating manual page 9 4.4 asi setup (airspeed setup) zero asi sensor: this setup allows your instrument to measure the zero airspeed reading of the airspeed sensor and set a calibration value internally for this. This is equivalent to some mechanical airspeed indicators that have an adj...

  • Page 10

    Vega asv-1 operating manual page 10 vne speed: (max exceed speed) enter you maximum speed you aircraft should not exceed. Vno speed: (max maneuvering speed) enter your maximum maneuvering speed. Vfe speed: (max flap speed) enter the maximum speed that is permissible with the flaps extended. Vs1 spee...

  • Page 11: 4.5 Timers Setup

    Vega asv-1 operating manual page 11 4.5 timers setup flight: select whether you want the asv-1 to automatically detect a flight or whether the pilot must press the f1/up button to start/stop a flight. We recommend you select automatic flight detection. T/o airspeed: this menu option is only shown if...

  • Page 12

    Vega asv-1 operating manual page 12 4.6 misc setup (miscellaneous setup) backlight: select this menu option to adjust the backlight brightness. Security setup: select this menu option if you want to password protect the menu system. Information: this menu option displays information about the unit..

  • Page 13: 4.7 Adc Values

    Vega asv-1 operating manual page 13 default settings: select this menu option to reset all the settings to factory defaults. 4.7 adc values this menu displays the adc value that have been read from the airspeed pressure sensor. 5 loading factory default settings press and hold the f1/up button and r...

  • Page 14: 6 Error Messages

    Vega asv-1 operating manual page 14 6 error messages unit settings crc error. Load default settings to restore to factory defaults. If the error message still persists then it could possibly be a non-volatile memory failure in which case the instrument will then have to be returned to the factory. C...

  • Page 15: 7 Asv-1 Specifications

    Vega asv-1 operating manual page 15 7 asv-1 specifications operating temperature range -10ºc to 60ºc (14ºf to 140ºf) storage temperature range -20ºc to 80ºc (-4ºf to 176ºf) humidity power supply 8 to 30vdc smps (switch mode power supply) with built in 33v over voltage and reverse voltage protection ...

  • Page 16: 10 Installation

    Vega asv-1 operating manual page 16 10 installation connect a pitot tube to the “pressure port” and if required connect the static port. Connect the static port to a suitable static air pressure line. If you have a slow aircraft or an aircraft where the internal cabin pressure does not change during...

  • Page 17: 11 Cleaning

    Vega asv-1 operating manual page 17 10.2 pressure port dimensions 10.3 asv-1 cable connections main connector (d15 connector: unit female, cable male) 11 cleaning the unit should not be cleaned with any abrasive substances. The screen is very sensitive to certain cleaning materials and should only b...

  • Page 18

    Vega asv-1 operating manual page 18 12 warranty this product carries a warranty for a period of one year from date of purchase against faulty workmanship or defective materials, provided there is no evidence that the unit has been mishandled or misused. Warranty is limited to the replacement of faul...