Vega VEGACONNECT 4 Operating Instructions Manual

Manual is about: Interface adapter between PC and communication-capable VEGA instruments with connection box

Summary of VEGACONNECT 4

  • Page 1

    Operating instructions interface adapter between pc and communication-capable vega instruments vegaconnect 4 with con- nection box interface converter usb - hart/i²c document id: 32628.

  • Page 2: Contents

    2 contents vegaconnect 4 with connection box • interface converter usb - hart/i²c 32628-en-170202 contents 1 about this document 1.1 function ........................................................................................................................... 3 1.2 target group ..................

  • Page 3: 1  About This Document

    3 1 about this document vegaconnect 4 with connection box • interface converter usb - hart/i²c 32628-en-170202 1 about this document 1.1 function this operating instructions manual provides all the information you need for mounting, connection and setup as well as important instruc- tions for mainte...

  • Page 4: 2  For Your Safety

    4 2 for your safety vegaconnect 4 with connection box • interface converter usb - hart/i²c 32628-en-170202 2 for your safety 2.1 authorised personnel all operations described in this operating instructions manual must be carried out only by trained specialist personnel authorised by the plant operat...

  • Page 5

    5 2 for your safety vegaconnect 4 with connection box • interface converter usb - hart/i²c 32628-en-170202 2.5 safety label on the instrument the safety approval markings and safety tips on the device must be observed. 2.6 eu conformity the device fulfils the legal requirements of the applicable eu ...

  • Page 6: 3  Product Description

    6 3 product description vegaconnect 4 with connection box • interface converter usb - hart/i²c 32628-en-170202 3 product description 3.1 configuration the scope of delivery encompasses: • vegaconnect 4 interface converter • connection box with two connection cables • usb cable • hart resistance • 2 ...

  • Page 7

    7 3 product description vegaconnect 4 with connection box • interface converter usb - hart/i²c 32628-en-170202 • delivery date (html) • order-specific instrument features (html) • operating instructions at the time of shipment (pdf) go to "www.Vega.Com", "vega tools" and "instrument search". Enter t...

  • Page 8

    8 3 product description vegaconnect 4 with connection box • interface converter usb - hart/i²c 32628-en-170202 possibility for the magnet pen. You can find further information of this application in the operating instruction of plicscom. The interface converter is connected via the usb interface to ...

  • Page 9: 4 Connection

    9 4 connection vegaconnect 4 with connection box • interface converter usb - hart/i²c 32628-en-170202 4 connection 4.1 connection to the pc note: first of all you should install the driver before connecting vegaconnect 4 to the pc. An usb interface (1.1/2.0/3.0) is compulsory for connection of vegac...

  • Page 10

    10 4 connection vegaconnect 4 with connection box • interface converter usb - hart/i²c 32628-en-170202 4.2 connection of the sensor/signal conditioning instrument vegaconnect 4 can be connected to virtually all communication- capable vega instruments. With instruments of the plics ® series it can be...

  • Page 11

    11 4 connection vegaconnect 4 with connection box • interface converter usb - hart/i²c 32628-en-170202 note: the connection of profibus pa or foundation fieldbus instruments is always carried out via the i²c interface on the sensor. A direct con- nection of vegaconnect 4 on the fieldbus is not possi...

  • Page 12: 5  Connection Examples

    12 5 connection examples vegaconnect 4 with connection box • interface converter usb - hart/i²c 32628-en-170202 5 connection examples 5.1 connection via i²c interface in hazardous ex areas, the hart or i²c cable of vegaconnect 4 can be connected to an ex approved sensor. Vegaconnect 4 and the pc mus...

  • Page 13

    13 5 connection examples vegaconnect 4 with connection box • interface converter usb - hart/i²c 32628-en-170202 1 2 op en twis t usb lo ck fig. 6: connection vegamet/vegascan via i²c interface 1 i²c bus (com.) interface 2 i²c connection cable note: communication with the sensor is carried out with v...

  • Page 14

    14 5 connection examples vegaconnect 4 with connection box • interface converter usb - hart/i²c 32628-en-170202 vegamet 381 on 1 2 1 2 % 1 3 2 op en twist usb lock fig. 7: connection plics ® series to a vegamet 1 hart sensor 2 connection cable with 2 mm pins 3 vegamet 381 or vegadis 371 1 3 2 open t...

  • Page 15

    15 5 connection examples vegaconnect 4 with connection box • interface converter usb - hart/i²c 32628-en-170202 4 1 2 3 fig. 9: connection plics ® series via hart 1 hart sensor 2 hart resistance 270 Ω (optional depending on processing) 3 connection cable with 2 mm pins and terminals 4 processing sys...

  • Page 16: 6 Setup

    16 6 setup vegaconnect 4 with connection box • interface converter usb - hart/i²c 32628-en-170202 6 setup 6.1 adjustment use and adjustment are described in the operating instructions man- ual as well as in the online help of pactware and the vega-dtms as well as in the respective device instruction...

  • Page 17

    17 7 maintenance and fault rectification vegaconnect 4 with connection box • interface converter usb - hart/i²c 32628-en-170202 7 maintenance and fault rectification 7.1 maintenance if the device is used properly, no special maintenance is required in normal operation. 7.2 how to proceed if a repair...

  • Page 18: 8  Recycling and Disposal

    18 8 recycling and disposal vegaconnect 4 with connection box • interface converter usb - hart/i²c 32628-en-170202 8 recycling and disposal 8.1 disposal the instrument consists of materials which can be recycled by spe- cialised recycling companies. We use recyclable materials and have designed the ...

  • Page 19: 9 Supplement

    19 9 supplement vegaconnect 4 with connection box • interface converter usb - hart/i²c 32628-en-170202 9 supplement 9.1 technical data electrical data voltage supply from usb interface 5 v max. Power consumption 500 mw galvanic separation between – hart - usb – i²c bus - usb ambient conditions permi...

  • Page 20

    20 9 supplement vegaconnect 4 with connection box • interface converter usb - hart/i²c 32628-en-170202 approvals instruments with approvals can have different technical specifications depending on the version. For that reason the associated approval documents of these instruments have to be carefull...

  • Page 21

    21 9 supplement vegaconnect 4 with connection box • interface converter usb - hart/i²c 32628-en-170202 9.3 industrial property rights vega product lines are global protected by industrial property rights. Further information see www.Vega.Com. Vega produktfamilien sind weltweit geschützt durch gewerb...

  • Page 22: Index

    22 index vegaconnect 4 with connection box • interface converter usb - hart/i²c 32628-en-170202 index c connection 11 d driver 9 dtm 7, 16 dtm collection 9 f foundation fieldbus 7, 11 h hart 7 – modem 7 – resistor 10, 11, 13 i i²c interface 10 instrument return form 17 instrument search 6 interface ...

  • Page 23

    23 notes vegaconnect 4 with connection box • interface converter usb - hart/i²c 32628-en-170202.

  • Page 24

    Printing date: vega grieshaber kg am hohenstein 113 77761 schiltach germany 32628-en-170202 all statements concerning scope of delivery, application, practical use and operat- ing conditions of the sensors and processing systems correspond to the information available at the time of printing. Subjec...