Example 2:
Set Egress Button in Holding contact of 10 seconds with warning beep
90
5
10
#
(a) (b) (c) (d)
(a)
Egress function programming,
(b)
Holding contact mode with warning,
(c)
Holding time of 10 seconds to release
door,
(d)
Entry confirmation
Example 3:
Set Egress Button in Momentary contact without delay (This is the default setting)
90
1
0
#
(a) (b) (c) (d)
(a)
Egress function programming,
(b)
Momentary contact without delay,
(c)
Release door instantly,
(d)
Entry
confirmation
CLOSE THE PROGRAMMING MODE (
* *
)
Always close programming mode with
* *
to set system back to normal Operation after programming.
VALIDATION
**
------------------------------- System is back to normal operation mode