Vemer Mithos GSM User Manual

Manual is about: Programmable

Summary of Mithos GSM

  • Page 1

    Cronotermostato digitale mithos gsm manuale d’uso user manual digital programmable thermostat.

  • Page 2: Index

    English - 1 - mithos gsm programmable thermostat user manual ■ assembly page 3 ■ dimensions page 4 ■ connection diagrams page 4 ■ safety warnings page 5 ■ technical characteristics page 5 ■ control elements / display indications page 7 ■ initial start-up / reset page 9 ■ clock setting page 9 ■ progr...

  • Page 3

    English - 2 - mithos gsm programmable thermostat user manual mithos digital programmable thermostat • power supply: 230 v ac (with rechargeable backup battery nimh type aa) • comfort and control of consumptions are ensured both in winter and in summer (heating/air conditioning) • integrated gsm modu...

  • Page 4: Assembly

    English - 3 - mithos gsm programmable thermostat user manual assembly • it is advisable to place the programmable thermostat in an area that mirrors, as much as possible, the conditions of average temperature of the entire environment. Avoid installing too close to doors, windows, heat sources, dire...

  • Page 5: Dimensions

    English - 4 - mithos gsm programmable thermostat user manual dimensions connection diagram ,qjuhvvrshu ;7hpsr',* &20 1$ 1& 1 / a 9a ,qsxwiru ;whpsru',* &20 1$ 1& 1 / t3 t2 t1 132 95 36.

  • Page 6: Technical Characteristics

    English - 5 - mithos gsm programmable thermostat user manual ■ during installation and operation of the product, it is necessary to comply with the following instructions: 1) the instrument must be installed by a skilled person, in strict compliance with the connection diagrams. 2) do not power on o...

  • Page 7

    English - 6 - mithos gsm programmable thermostat user manual - t0 antifreeze temperature setting in advanced programming - t temperature in manual operation • temperature regulation: - on/off with differential setting between 0.1°c and 1°c - proportional with proportional band and regulation period ...

  • Page 8: Control Elements

    English - 7 - mithos gsm programmable thermostat user manual 5 10 2 1 3 4 6 9 11 12 13 8 7 ■ control elements 1) “ ” key : manual operation 2) “ ” key : increases the selected field or displays the daily maximum temperature 3) “ ” key : decreases the selected field or displays the daily minimum temper...

  • Page 9: Display Indications

    English - 8 - mithos gsm programmable thermostat user manual ■ display indications 14) “day” field 15) “external temperature” field 16) “environment temperature” field 17) “set program” field 18) “manual operation activation” field 19) “timer” field 20) “air conditioning activation” field 21) “heati...

  • Page 10: Initial Start-Up / Reset

    English - 9 - mithos gsm programmable thermostat user manual initial start-up / reset • connect the output, power supply and, if present, the expernal probe (or digital input) in accordin to the diagram shown in page 4. After applyng power, all the display segments will turn on and the relay will be...

  • Page 11

    English - 10 - mithos gsm programmable thermostat user manual at this point, the minutes digit will start flashing. Use the “ ” and “ ” keys to increase or decrease the field and press “ ” to confirm. Repeat the procedure to set the hours. Once the value for the hours is set, field (22) will display a fl...

  • Page 12: Programs Setting

    English - 11 - mithos gsm programmable thermostat user manual programs setting • pressing the “ prg ” key on field (14) will display the indication regarding monday, field (16) will display the selected program flashing (in the example: p1), field (15) will display “ pro ” , field (17) will display the g...

  • Page 13

    English - 12 - mithos gsm programmable thermostat user manual with the t1 , t2 and t3 keys, it is possible to modify the temperature selected for that hour and, at the same time, move on to the next one. Using the “ ” and “ ” keys, it is possible to move from one hour to the next without modifying t...

  • Page 14: Temperatures Setting

    English - 13 - mithos gsm programmable thermostat user manual temperatures setting • in any of the operation modes, pressing the t1 , t2 and t3 keys will bring field (22) to display the writing corresponding to the temperature that is being modified; on field (16) the value of the aforementioned temper...

  • Page 15: Manual Operation

    English - 14 - mithos gsm programmable thermostat user manual manual operation • during automatic operation, when pressing the “ ” key, the system will act as a normal thermostat with operating temperature tm. Field (22) will show the current time. Field (14) will show the current date. Field (15) w...

  • Page 16: Summer / Winter Operation

    English - 15 - mithos gsm programmable thermostat user manual summer / winter operation to move from winter to summer operation (or vice versa), press the “ ” key with a point (12) . On field (22) the writing “ risc ” (or “ cond ” ) will flash and the symbol “ ” (or “ ” ) will appear. With the “ ” and...

  • Page 17: Keypad On-Off Command

    English - 16 - mithos gsm programmable thermostat user manual • to deactivate the programmable thermostat press the “ ” key. The display will show the “ ” symbol. Once deactivated, during winter operation the programmable thermostat will activate the antifreeze function to ensure that the temperatur...

  • Page 18

    English - 17 - mithos gsm programmable thermostat user manual to activate timing it is necessary to press the “ ” key the writing “ 00h ” will flash, indicating the timing. With the “ ” and “ ” keys it is possible to choose a value between 0 and 99. Pressing the “ ” key will allow to choose the measu...

  • Page 19: Advanced Programming

    English - 18 - mithos gsm programmable thermostat user manual advanced programming • in advanced programming it is possible to access the following operation parameters: - regulation type - parameters for regulation type - antifreeze temperature - temperature measurement unit - measured temperature ...

  • Page 20

    English - 19 - mithos gsm programmable thermostat user manual • using the “ ” and “ ” keys, choose the desired regulation mode and press “ ” to confirm and move to the setting of the next parameter. Parameters for the chosen regulation type (only for winter operation) • in case of “ on/off ” regulati...

  • Page 21

    English - 20 - mithos gsm programmable thermostat user manual antifreeze temperature (only for winter operation) • it is possible to set a safety temperature value (antifreeze temperature) to be maintained in case the programmable thermostat is deactivated. Field (22) will display the writing “ off=...

  • Page 22

    English - 21 - mithos gsm programmable thermostat user manual field (22) will display the writing “ est= ” and on field (16) the selected option will flash. Choose “ °c ” (or “ °f ”) if you want to connect an external probe or choose “ dig ” if you want to connect an auxiliary device. If you choose “ ...

  • Page 23

    English - 22 - mithos gsm programmable thermostat user manual page gsm functions thys page is related to the remote operation and is treated in detail in the “gsm interface” chapteh on page 27. Keypad lock password it is possible to choose a three digit value to be used to unlock the keypad. Field (...

  • Page 24: Advanced Functions

    English - 23 - mithos gsm programmable thermostat user manual it is to be read from left to right. In the example the value is of 1274 hours). Two independent totalizers for winter and summer operation are present. The maximum memorizable value is of 65535 hours. To reset the counter, press the “ ” ...

  • Page 25

    English - 24 - mithos gsm programmable thermostat user manual the settings for both menus are, in order: - week of the month ( 1st first, 2nd second, 3rd third, 4th fourth, lst last) - day of the week - month - changing hour at the end of each menu, press the “ ” key again to access the next menu or ...

  • Page 26

    English - 25 - mithos gsm programmable thermostat user manual display of max/min daily temperature the programmable thermostat memorizes the minimum and maximum temperature values measured both from the internal probe as well as from the external one during the day. To view such values press the “ ”...

  • Page 27: Regulation Type

    English - 26 - mithos gsm programmable thermostat user manual regulation type the default regulation type is on/off with deactivation in correspondence with the setpoint and with differential set to 0.3°c. Relay on set-diff set relay off temperature increasing relay on set+diff set relay off tempera...

  • Page 28: Gsm Interface

    English - 27 - mithos gsm programmable thermostat user manual choose the regulation band value as follows: • broad band (5°c) for systems with high thermal gradient • narrow band (0.5°c) for systems with low thermal gradient gsm interface ■ the mithos gsm integrates a gsm module that makes it possib...

  • Page 29

    - 28 - mithos gsm programmable thermostat user manual notes: – the words must be separated by one or more empty spaces – the password field may be omitted if the message sender is a number in the telephone book (see telephone book management below) – several commands may be included in a single mess...

  • Page 30

    - 29 - mithos gsm programmable thermostat user manual recording numbers in the telephone book the mithos gsm makes it possible to store up to 5 numbers in the telephone book, identified with a progressive number from 1 to 5, which may activate/deactivate the instrument with a ring or send command te...

  • Page 31

    - 30 - mithos gsm programmable thermostat user manual for example: rubrica 2 3921234567 the telephone book responds with a confirmation text message containing the complete telephone book (if a number is not defined, it is indicated with “vuoto”). Multiple numbers can be added with one text message....

  • Page 32

    - 31 - mithos gsm programmable thermostat user manual book, the index of the corresponding memory will start to flash (in the example to the side, the number is in position 4). Adding a number to the telephone book numbers can be added to the telephone book with a simple telephone ring, without the ...

  • Page 33

    - 32 - mithos gsm programmable thermostat user manual the number in the telephone book that made the call will receive a text message informing of the programmable thermostat status. Some examples: mithos=acceso (automatico) mithos=spento (antigelo=02.0 c) mithos=acceso (manuale=20.0 c) mithos=spent...

  • Page 34

    - 33 - mithos gsm programmable thermostat user manual some examples: mithos=acceso (automatico) mithos=spento (antigelo=disabilitato). Setting the heating/air conditioning mode the heating or air conditioning operating mode can be set with a text message. The syntax of the commands to send are: mith...

  • Page 35

    - 34 - mithos gsm programmable thermostat user manual defining the manual temperature using the tm command, the manual temperature of the current operating mode (heating or cooling) can be set. The syntax of the command to send is: tm [tt.T] where [tt.T] values between 2.0 and 50.0 for example: tm 1...

  • Page 36

    - 35 - mithos gsm programmable thermostat user manual requesting information with the commands mithos info and mithos info tutto, the programmable thermostat can be queried to receive information regarding system status. In particular, with mithos info tutto, the following information can be receive...

  • Page 37: Managing The Alarms

    - 36 - mithos gsm programmable thermostat user manual network power supply optimal gsm field coverage (100%) number of the mithos gsm card: 3331234567 (nd if not defined) date: 01 july 2010 time: 14:55:23 “ (reg) ”, which in this case follows the measured internal probe temperature, indicates which ...

  • Page 38

    - 37 - mithos gsm programmable thermostat user manual where: [recipient] indicates the number in the phone book to which the alarm is sent some examples: invio allarme esterno 1 3 4 sends a text message to numbers 1, 3, 4 in the telephone book if there is a digital input alarm invio allarme massima ...

  • Page 39

    - 38 - mithos gsm programmable thermostat user manual imposta allarme contatto restores the current configuration of the input alarm some examples: imposta allarme contatto aperto 10 digital input alarm if the programmable thermostat input has an open status for at least 10 seconds imposta allarme c...

  • Page 40

    - 39 - mithos gsm programmable thermostat user manual where: [probe] int is you want to use the internal probe, ext for an external probe [threshold] temperature limit value [hysteresis] value used to calculate the alarm return threshold. It is subtracted from the threshold in the case of a maximum ...

  • Page 41

    - 40 - mithos gsm programmable thermostat user manual fine allarme alimentazione=ripristinata (gg/mm/aa hh:mm) by default, the number in the telephone book with index 1 receives the network failure alarm. Note: the alarm message is not sent instantaneously, but there is a delay of a few seconds (sig...

  • Page 42

    - 41 - mithos gsm programmable thermostat user manual an extended blackout - longer than the battery charge of approx. One hour - these values are lost and the programmable thermostat will stop all regulations until the date and time are reset. These values can be reset either automatically or manua...

  • Page 43: Backup Battery

    - 42 - mithos gsm programmable thermostat user manual backup battery the instrument has a backup battery that permits operation in the case of a power supply failure until it is completely discharged. The battery is recharged by mithos gsm: the battery is completely recharged after approx. 24 hours ...

  • Page 44: Winter Programs

    - 43 - mithos gsm programmable thermostat user manual winter programs p1 t3 ■ ■ ■ ■ ■ ■ ■ t2 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ t1 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 p2 t3 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ t2 ■ ■ ■ ■...

  • Page 45: Summer Programs

    - 44 - mithos gsm programmable thermostat user manual summer programs p1 t3 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ t2 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ t1 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 p2 t3 ■ ■ ■ ■ ■ ■ ■ ■ ■ t2...

  • Page 46: Summar

    Summar y of the main remote commands: command p arameters description r ubrica [index] [number] adds the [number] to the telephone book position [index] mithos numero [number] stores the added sim [number] in mithos gsm mithos acceso automa tico turns on mithos gsm in automa tic mode mithos acceso m...

  • Page 47: Summar

    Summar y of the main remote commands: command p arameters description invio allarme minima [recipient1]… [recipient5] indica tes the numbers in the telephone book to which the minimum tempera ture threshold exceeded alarm is sent invio allarme massima [recipient1]… [recipient5] indica tes the number...

  • Page 49: Vemer S.P.A.

    V3iso0580-011 vemer s.P.A. I - 32032 feltre (bl) via camp lonc, 16 tel +39 0439 80638 fax +39 0439 80619 e-mail: info@vemer.It - web site: www.Vemer.It.