Veneto VT-ANG30 User Manual

Summary of VT-ANG30

  • Page 1

    1 general user manual chimney hood wall: vt-ang30, vt-ang36,vt-ang650, vt-vit30, vt-vit36, vt-zen2, vt-zen30, vt-zen36,vt-zen650 vt-bac30 isalnd hood: vt-ang36il, vt-vit36il, vt-zen36il, vt-zen3612il, vt-zen42il under cabinet hood : vt-reg30,vt-reg30w,vt-con30 pro under cabinet hood: vt-proc30,vt-pr...

  • Page 2: Summary

    Summary safety notice….............................................................................................................................3-4 electrical requirements and installation requirements..................................................................5 examples and positioning pos...

  • Page 3: Safety Notice

    3 safety notice approved for residential type units for residential use only read these instructions and be safe. Please read these instructions completely before starting. The installation of the appliance must respect all codes. Important: save these instructions so that you can provide the electr...

  • Page 4: Warning

    Warning to avoid injuring someone in a grease fire, follow the following: 1. Smother flames with a lid to the dimensions of the cooking hobs, a cookie sheet or other metal tray, then turn off the gas or power supply of the stove. Be careful not to burn yourself. If the flames do not go out immediate...

  • Page 5

    5 electrical requirements and installation requirements power requirements important observe all governing codes and ordinances. The customer is responsible for: contacting an electrician-installer. Check that the electrical installation is adequate and in conformance with the national electrical co...

  • Page 6

    Examples and positioning possibilities ducts follow the letter of the guidelines presented in this manual. The manufacturer declines any liability with respect to any loss, damage or fire caused by non-observance of the instructions contained in this manual. Ventilation methods the hood is equipped ...

  • Page 7: Chimney Hood Wall: Vt-Bac30

    7 chimney hood wall: vt-bac30 positioning options for the hood ducts vt-bac30 vertical outlet 6'' round and rectangular horizontal rear exit 4'' 1/2'' x 9'' or 3 1/4 x 10'' provides.

  • Page 8

    Exit 4’’ 1/2 x 9’’ include exit 3’’1/4 x 10’’ include.

  • Page 9: Vt-Zen42Il

    9 island model hood : vt-ang36il, vt-vit36il, vt-zen36il, vt-zen3612il, vt-zen42il positioning options for blocks ducts hoods vertical duct 7'', maximum length pipe is 20’.

  • Page 10

    Under cabinet models: vt-proc30,vt-proc36 vertical duct 8'' maximum length pipe is 20’ positioning options for hood ducts under cabinets.

  • Page 11

    11 under cabinet models : vt-reg30, vt-reg30w,vt-con30 vertical and horizontal rectangular pipe 3'' 1/4'' x 10 required, otherwise it will create additional noise. Maximum length pipe is 15’.

  • Page 12

    Insert hood models : vt-in2816,vt-in2812 positioning options for blocks ducts hoods maximum length pipe is 20’.

  • Page 13: Clearance

    13 clearance training do not cut a joist or stud unless it is absolutely necessary to do so. If you need to cut a joist or stud, you must build a support framework. Supplied hardware can secure the hood to most walls and ceilings. However, you should ask a qualified technician to check the strength ...

  • Page 14: Installation

    Installation installation - version with duct • if possible, unplug the stove and move it in order to have better access to the rear wall. Otherwise, place a thick blanket on the counter and the cooking surface to protect it from damage and dirt. Select a flat surface for assembling the device. Plac...

  • Page 15

    15 installation and dimensions diagram, patterns for chimney hood vt-ang30, vt-ang36,vt-ang650 vt-vit30, vt-vit36 vt-zen30, vt-zen36, vt-zen2, vt-zen650 vt-bac30

  • Page 16

    Installation and dimensions diagram, patterns for hood's chimney.

  • Page 17

    17 installation and dimensions diagram, patterns for island hoods vt-ang36il vt-vit36il.

  • Page 18

    Installation and dimensions diagram, patterns for island hoods vt-zen36il, vt-zen42 installation dimensions and patterns for island hoods, ceiling pattern for up to 12 vt-zen3612il.

  • Page 19

    19 installation and dimensions diagram patterns for island hoods.

  • Page 20

    Installation and dimensions diagram, patterns for hoods: vt-proc30,vt-proc36.

  • Page 21

    21 installation and dimensions diagram, patterns for hoods: vt-proc30,vt-proc36.

  • Page 22: Remote Sensor:

    Description orders for model: vt-proc30, vt-proc36 automatic activation control function of the sensor : when the hood is off, press the k1 button to enter the automatic sensor mode, an automatic detection mode, the fan does not turn unless it detects gas. Then it will turn off automatically as long...

  • Page 23: Vt-Reg30,vt-Reg30W,vt-Con30

    23 horizontal installation dimensions, diagrams for models of hoods: vt-reg30,vt-reg30w,vt-con30

  • Page 24: Vt-Reg30,vt-Reg30W,vt-Con30

    Vertical installation dimensions and patterns, diagram for hoods: vt-reg30,vt-reg30w,vt-con30

  • Page 25: Vt-In2816

    25 vertical installation dimensions and patterns, diagram for hoods: vt-in2816.

  • Page 26: Vt-In2812

    Vertical installation dimensions and patterns, diagram for hoods: vt-in2812.

  • Page 27: Vt-In2812

    27 description orders for all models except vt-proc30, vt-proc36, vt-in2816, vt-in2812 k4 k3 k2 k1 k1: power on / off: when the hood is on, press k1 key to enter power-off delay timer. K2:light knob: press this button to turn on the light again, turn off the light. K3, k4: button to decrease and inc...

  • Page 28

    Description orders for model vt‐in2816 press + to switch on the fan .The timer will only operate when the fan is switch on press – to decrease the fan speed press + to increase the fan speed to switch on or off the lights up to 15 minutes timer setting and fully adjustable. When you press the timer ...

  • Page 29: Maintenance

    29 maintenance warning before servicing or cleaning unit, switch power off at service panel and lock in access to prevent it being switched on accidentally. If the power panel can not be locked, put a prominent warning device, such as a brightly coloured label. Grease filters the grease filters shou...

  • Page 30: Warranty

    Warranty the hood veneto three year limited warranty range hoods veneto warrants to the original consumer of its products that they are free from manufacturing defects, both in terms of raw materials and labor for a period of three (3) years from the date of original purchase. This warranty includes...