Venmar FAE115 Installation And User Manual - Caution

Manual is about: Furnace Air Exchanger with Heat Recovery

Summary of FAE115

  • Page 1

    Installation and user manual address of your installer 04423 07/04/00 furnace air exchanger with heat recovery c a n a d i a n m o d e l s u s m o d e l s fae115 vfae115 ufae115 fae115m vfae115m ufae115m installer: leave this manual to homeowner customer service phone number: 1-800-567-3855 vb0026.

  • Page 2: Warning

    This manual uses the following symbols to emphasize particular information: note: indicates supplementary information needed to fully complete an instruction. 2 about this manual warning identifies an instruction which, if not followed, might cause serious personal injuries including possibility of ...

  • Page 3: 1.0

    1.0 s ervice . . . . . . . . . . . . . . . . . . . . . . . . .4 1.1 service parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.2 parts ordering chart . . . . . . . . . . . . . . . . . . . . . . . . . . .4 2.0 t echnical d ata . . . . . . . . . . . . . . . . . . . .4 2.1 air d...

  • Page 4

    1.1 s ervice p arts 4 1.0 s ervice 1.2 p arts o rdering c hart number 1. 2. 3. Part description basic filter heat recovery core damper motor part number 04432 04433 canada/ 04455 us 04434 vl0004 2 2 1 1 3 note: unit in normal position. Can also be installed upside down. Fae115m, ufae115m & vfae115m ...

  • Page 5

    5 these following curves illustrate the air volume through the units for a typical installation. A typical installation is close to an exterior wall, in order to shorten the insulated duct length. On the warm air side (between the unit and the furnace), use steel rigid ducts. It is strongly recommen...

  • Page 6

    6 3.0 t ypical i nstallation the figure 2 below illustrates a typical installation. The fresh air intake hood must be at least 6’ (1.8 m) away from the outdoor exhaust hood (measurement a ), the fresh air from outside duct must be at least 6’ (1.8 m) away from the furnace (measurement b ) and the st...

  • Page 7: Caution

    7 4.2 c onnecting d ucts to the u nit insulated flexible ducts: use the following procedure for connecting the insulated flexible ducts to the ports on the unit (exhaust to outside and fresh air from outside). A) pull back the insulation to expose the flexible duct. B) connect the interior flexible ...

  • Page 8

    8 4.4 c onnecting the d rain a) attach the 2 plastic drain fittings to the unit using the gaskets and nuts as shown. B) cut 2 sections of plastic tubing, about 12”(305 mm) long and attach them to each drain fitting. C) join these 2 short sections to the “t” junction and main tube as shown. D) make a...

  • Page 9: Installation of Flow Collars

    9 5.0 a ir f low b alancing • a magnehelic gauge capable of measuring 0 to 0.25 inches water gauge (0 to 62.5 pa) and 2 plastic tubes. • two flow collars (6” diameter). What you need to balance the unit preliminary stages for balancing the unit insert the flow collars in the duct at each location. M...

  • Page 10: Balancing Procedure

    10 1. Set the furnace blower to high speed. 2. Place the magnehelic gauge on a level surface and adjust it to zero. 3. Connect tubing from gauge to flow collar in exhaust air stream at location a (figure 5 on page 9). Be sure to connect the tubes to their appropriate high / low fitting. If the gauge...

  • Page 11: Inside

    11 6.1 u nit d escription 6.0 your unit vl0004 1. Basic filter 2. Heat recovery core 3. Damper system (only on fae115m, ufae115m and vfae115m units) 1 2 2 3 1 unit in normal position. Can also be installed upside down. Fae115, ufae115 & vfae115 fae115m, ufae115m & vfae115m 6.2 h eat r ecovery this u...

  • Page 12: Caution

    12 7.1 i nstructions r egarding w all c ontrol (fae115m, u fae115m and v fae115m only ) 7.2 w iring d iagram • major renovation work • sanding of gypsum joints • house building • varnishing during very heavy snow storm, the unit should also be turned off to avoid problems caused by snow entering the...

  • Page 13: Warning

    13 1. Set the wall control to 80%. (fae115m, ufae115m and vfae115m only) 2. Unlatch the door. Lift the panel towards you. Hold it firmly and hit on the right side of the pannel. The door should slide to the left. 3. Clean the filter • remove filter. • vacuum to remove most of the dust. • wash with a...

  • Page 14: Caution

    14 8.1 e very t hree m onths (cont’d) 6. Reinstall the components: • heat recovery core • filter • door (the door is secured when you hear a click.) 7. Check the exterior air intake hood : • make sure there are no leaves, twigs, ice or snow that could be drawn into the vent. • clean if necessary. 8....