Venmar ISPIRA IB700 Series Installation Instructions Manual - Table of Contents

Summary of ISPIRA IB700 Series

  • Page 1

    Ic700, ic700es* and ib700 series hb0134 intended for domestic cooking only installer: leave this manual with homeowner. Homeowner: use and care information on pages 17 to 19. Read and save these instructions venmar ventilation ulc, 550 lemire blvd., drummondville qc j2c 7w9 1-800-567-3855 register y...

  • Page 2: Warning

    2 to reduce the risk of fire, electric shock or injury to persons, observe the following: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty. 2. Before servicing or cleaning unit,...

  • Page 3

    3 - ic700, ic700es and ib700 series range hood system - hl0226 m odel 639 (3¼” x 10” w all c ap m odel 634 or 644 (r oof c ap ) m odel 639 (3¼” x 10” w all c ap ) m odel 428 ( optional 3¼” x 10” e lbow ) u pper d ecorative f lue (ic700 and ic700es) l ower d ecorative f lue (ic700 and ic700es) m odel...

  • Page 4: Table of Contents

    4 plan where and how the ductwork will be installed. The ducting from this fan to the outside of the building has a strong effect on the air flow, noise and energy use of the fan. Use the shortest, straightest duct routing possible for best performance, and avoid installing the fan with smaller duct...

  • Page 5: 2. Prepare

    5 2. Prepare the installation note: before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the manufacturer. Make sure that the following items are included: - hood - accessories • decorative flue assembly (lower and upper flues) (ic700 and ic7...

  • Page 6: 2. Prepare

    6 2. Prepare the installation ( cont ' d ) refer to illustration at right to locate duct opening for vertical discharge. 3. Remove hybrid filters lay the back of the hood on a table. Use a piece of cardboard to avoid damaging the table or the hood. Remove tape on filters. Remove filters by pushing t...

  • Page 7: 5. Prepare

    7 4. Install glass panel (wg models only ) ( cont ' d ) 2. Carefully remove the glass panel from its packaging. Remove glass panel nuts (factory installed) from both studs and set aside. 3. Insert glass panel studs in the appropriate hood holes. 4. While holding the glass panel, pre-tighten the prev...

  • Page 8: 6. Blower

    8 6. Blower removal ( horizontal discharge only - ic700 and ib700) the ic700, ic700es and ib700 series range hoods are factory shipped with the blower mounted for a vertical discharge configuration. For a horizontal discharge configuration in models ic700 and ib700, disassemble the blower from the i...

  • Page 9: 7. Install

    9 2. Using a 5/16” socket, or a robertson or phillips no. 2 screwdriver, remove all blower mounting screws from the inner top of the hood. Set blower and screws aside. Hd0385 hd0386 l eft side mounting screw location r ight side mounting screw location 7. Install the adapter/damper h orizontal disch...

  • Page 10: 7. Install

    10 v ertical discharge mount the 3¼” x 10” adapter/damper to the top of the hood using 2 no. 8 x 3/8” screws (included). Seal the adapter/damper to the hood using metal foil duct tape. 7. Install the adapter/damper ( cont ' d ) hj0065 s crew location 8. Wiring installation warning ! Improper groundi...

  • Page 11: (Ic700 And Ic700Es)

    11 9. Install hood mounting bracket (ic700 and ic700es) warning ! When cutting or drilling into wall, do not damage electrical wiring and other hidden utilities. Construct wood wall framing that is even with the surface of the wall studs. Make sure to assemble wood wall framing to wall studs for a s...

  • Page 12: 12. Reinstall The Blower

    12 11. Install the hood (ic700 and ic700es) warning ! Be careful when installing the decorative flue and hood, they may have sharp edges. Caution do not remove yet the protective plastic film covering the decorative flues (upper and lower). Hd0417a l ower holes location u pper holes location Ø 3/16”...

  • Page 13: 13. Duct Connection

    13 13. Duct connection (vertical discharge only - ic700 and ic700es) 1. Plug hood power cord into the outlet. 2. Slide the duct over the adapter/damper on the hood. 3. Use metal foil duct tape to seal the joint. Note: if a transition to 7” or 8” round duct is used, it is recommended to place it at l...

  • Page 14

    14 15. Install the decorative flue (ic700 and ic700es) 1. To prevent the flue from moving, affix the included foam squares on both sides near the front edge of the blower box (as illustrated at right). 2. Carefully slide in place decorative lower flue (notches end first) on top of the hood ( 1 ) unt...

  • Page 15: 16. Built-In Installation

    15 although this is a chimney range hood, it can also be installed built-in the cabinetry without its chimney. Following is our recommended built-in installation. Note: installation may vary depending on the cabinet set-up. 1. Follow steps presented in sections 1 to 8. 2. A) h orizontal d ischarge :...

  • Page 16: (Ib700)

    16 note: for better precision, the illustration at right shows the screws location on the left side of the hood only; their location is the same on the right side of the hood. 4. Slide the blower box in the opening and secure the hood to the bottom of the cabinet using 6 screws ( a ) (3 screws on ea...

  • Page 17: 19. Care

    17 19. Care h ybrid filters hybrid filters should be cleaned monthly. Remove hybrid filters by pushing them towards the back of the hood and flipping them downward. Use a warm detergent solution to clean the filters. Let them dry and reinstall them. Hybrid filters are dishwasher safe. Clean all-meta...

  • Page 18: 20. Operation

    18 20. Operation always turn your hood on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes to clear the air after you turn off the range. Caution after a power failure or during the range hood power up, a 5-second booting sequence is executed. Wa...

  • Page 19: 20. Operation

    19 20. Operation ( cont ' d ) h eat s entry ™: the hood is equipped with a heat sentry thermostat. If blower is on at a lower speed setting and excessive heat is detected above the cooking surface, it turns the blower up to third speed. When the temperature level drops to normal, the blower will ret...

  • Page 20: 21. Wiring Diagram

    20 21. Wiring diagram warning ! Risk of electric shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting means to prevent power from being switched on...

  • Page 21: 22. Service Parts

    21 k ey no . P art no . D escription w idths 30" 36" 1 sv09955xx* g lass p anel 30” 1 0 1 sv09956xx* g lass p anel 36” 0 1 2 09550 e lectronic c ontrol 1 1 3 09022 t ransformer 1 1 4 62612 led module (1) 2 2 5 62053 h ybrid filter 15.875” x 14” x 0.5” (1) 2 2 6 sv08582 i nternal blower 1 1 7 62248 l...

  • Page 22: 23. Warranty

    22 23. Warranty venmar ventilation five-year warranty venmar ventilation ulc warrants to the original consumer purchaser of the venmar ispira ic700, ic700es and ib700 series range hood that such product will be free from defects in materials or workmanship for a period of five (5) years from date of...