Vent-a-Hood B100 Single Installation Instructions Manual

Summary of B100 Single

  • Page 1

    Page 1 l110 1213a ul c us r read and save these instructions all hoods must be installed by a qualified installer installation instructions wall mount hood read all instructions thoroughly before beginning installation warning - to reduce the risk of fire, electric shock, or injury to persons, obser...

  • Page 2: Ducting Do’S and Don’Ts

    Page 2 l110 1213a ducting do’s and don’ts yes no smooth duct smooth gradual turn proper combining of two ducts flexible duct sharp angled turns improper combining of two ducts general requirements • observe local codes regarding special duct requirements and placement of duct against combustibles. •...

  • Page 3: Installation Details

    Page 3 l110 1213a installation details 1) read all instructions thoroughly before beginning installation. Note: these instructions apply to standard hoods only. Custom hoods may require additional specification consideration. 2) when installing a wall mount range hood, it is recommended that the bot...

  • Page 4

    Page 4 l110 1213a 6” outlet vent hole 3 ¼” electrical centerline of hood wall side 1 ¾” 1 3⁄8” 5 ¼” electrical 1 ¾” centerline of hood 8” outlet vent holes 5 ¼” 5 ½” wall side 8” outlet 6” outlet 5 ¼” wall side vent holes centerline of hood electrical (2) 5 ½” 7 5⁄16” 1 7⁄8” 7 5⁄16” 1 ¾” 11” 11” 5 ½...

  • Page 5

    Page 5 l110 1213a 8) install an appropriate 1/2" ul listed electrical wire clamp through each motor box electrical opening on top of the hood. Install electrical wiring from the service panel to the hood location for each motor box. Consult the connection diagrams (on previous page) for further deta...

  • Page 6

    Page 6 l110 1213a 14) for back venting applications only. If you are not back venting, proceed directly to step 15. Method 1: place the appropriate elbow(s) on the top of the hood. Elbow(s) should be placed with the non-crimped end(s) on the inside the collar(s) of the exhaust outlet(s). Use duct ta...

  • Page 7: Venting

    Page 7 l110 1213a venting accessories 6” rectangular duct pipe model dim vp507 6” x 8 ½” 24” 8 ½” 6” round duct pipe model dim vp500 vp501 vp502 6” round 7” round 8” round 36” 6” 7” 8” 3 ¼” rectangular duct pipe model dim vp504 vp505 vp506 3 ¼” x 10” 3 ¼” x 12” 3 ¼” x 16” 30” 10” 12” 16” 3 ¼” offset...