Vent-a-Hood JCIH/A1 Installation Instructions Manual - page 4
Page 4
JCIH/A1 0516A
12" Round
12" Round
11 ¼"
8" Round
8" Round
8" Round
9"
16"
5"
8" Round
8" Round
Centerline
Of Hood
Centerline
Of Hood
¾”
Electrical
Vent Holes
2 1⁄8”
5” x 16”
Exhaust
Opening
8” Transition
Opening
12" Transition
Opening
1 ¾"
8” Blower
Outlets
Vent Holes
5 ½"
10 ½"
Centerline
of Hood
Centerline
of Hood
Electrical (2)
Installation Details Continued
Connection Diagram (48”- 66” Widths)
Connection Diagram (36”- 48” Widths)
550 CFM T200 Dual Blower
(Top View)
1100 CFM T400 Dual Blowers
(Top View)
Transition Installed
(Side View)
VP565 Standard Transition
(Included)
VP564 Standard Transition
(Included)
Transition Installed
(Side View)
6) Remove the shipping tape that is securing the E-Z Clean shields inside the hood. Remove the E-Z Clean shields by
lightly pulling each toward the end of the hood. Gently close the back draft dampers from the top side of the hood. To
remove the blower housings, unsnap the suitcase latches (one on each side of the housing). The housings should be
pulled forward and gently “tipped” to clear the blower wheels and then out of the hood.
Warning: Make sure power is off and locked at the service disconnecting
means on the service panel during installation.
7)
Remove the three screws retaining each blower motor. Unplug and remove the motors,
taking care not to damage the blower wheels. It is not necessary to remove the blower
wheels from the motors.
8) Turn the hood over on the protective surface. Attach the transition to the blower outlets
and seal with duct tape. The transition must fit inside the exhaust collar(s) on the blower
assembly.