Vent-a-Hood ZTH Installation Instructions Manual

Summary of ZTH

  • Page 1

    Page 1 (rev. 02/08) l118 ul c us r read and save these instructions all hoods must be installed by a qualified installer installation instructions zth wall mount hood read all instructions thoroughly before beginning installation warning - to reduce the risk of fire, electric shock, or injury to per...

  • Page 2: Ducting Do’S and Don’Ts

    Page 2 (rev. 02/08) l118 ducting do’s and don’ts never restrict the duct size. The single blower unit (b100) requires 6” round duct or equivalent (28 square inches), and the dual blower unit (b200) requires 8” round duct or equivalent (50 square inches). When combining ducts together, the square inc...

  • Page 3: Installation Details

    Page 3 (rev. 02/08) l118 36” 8’ ceiling 30” 12” optional duct cover wall side 6" outlet centerline of hood vent holes 8" outlet wall side electrical (2) 5 1/4" 4 1/2" 6 7/16" 8 3/16" 1 7/8" 1 3/4" installation details 1) read all instructions thoroughly before beginning installation. 2) when install...

  • Page 4

    Page 4 (rev. 02/08) l118 model b100 single volts amps rpm cfm sp@0.0” equivalent cfm cfm sp@0.1” cfm sp@0.2” cfm sp@0.3” minimum round duct size square inches # b200 dual 115 115 1.7 3.4 1550 1550 300 600 450 900 286 572 270 540 240 480 6” (or equivalent) 8” (or equivalent) 28 50 note: add 2.5 amps ...

  • Page 5

    Page 5 (rev. 02/08) l118 11) for back venting applications only. If not back venting, proceed directly to step 12. Note: wall studs may interfere with back venting installations. Additional framing may be required. It is necessary to cut a duct access hole in the wall prior to installing the hood. T...

  • Page 6

    Page 6 (rev. 02/08) l118 venting accessories 6”,7”,8” 36” vp500 6” vp501 7” vp502 8” model dim 4 1/4” 3 1/4” 10” 3 1/4” 14” back vent elbow vp559 3 1/4”x10” model dim 10 to 7 transition 7” 7 1/2” 10” 3 1/4” model dim vp521 3 1/4” x 10”- 7” low profile roof jack (maximum 4/12 pitch) 16 3/4” 6 1/2” 16...