3.0 Installation
3.2 Installing the Power Supply Unit
1. Remove the power supply unit assembly
from the carton. (Fig.6)
2. Remove the power supply unit packaging.
3. The mains input to the power supply unit
must be routed via the rear of a single gang
surface mounted back box (not supplied).
NOTE: Mains wiring must be kept separate
from the SELV wiring.
The mains connection is to the terminals
marked L & N (Fig.7)
4. Feed the 3-core cable through the rear of the
back box.
5. Mark the fixing hole positions in the back box
(not supplied) then Drill and plug the wall to
secure the power supply enclosure using the
fixing screws provided.
6. Connect the 5m cable supplied to the red,
white and black low voltage supply via the
terminal block. (Fig. 7)
NOTE: Red is positive high speed, white is
positive low speed and black is negative.
This polarity must be maintained at the unit
connections.
HR25/HR25L ONLY
The HR25/HR25L units are factory set to
opearate continuously at high or low speed
via a pull cord switch.
Two alternative settings can also be
achieved by disconnecting and making safe
the respective wires at the cable end of the
terminal block within the power supply
enclosure. The settings are as follows:-
High speed / Off – Disconnect White (Fig.8)
Low speed / Off – Disconnect Red (Fig.9)
N.B For all other models, refer to the
respective installation page.
L
~ N
SELV Supply
N
+
-
24V
0V
8V
+
RED
W HITE
BLACK
220-240V~50H z
R EF: 447249
0-24V D.C
RED
BL
AC
K
WHI
T
E
L
~ N
SELV Supply
N
+
-
24V
0V
8V
+
RED
WHITE
BLACK
220-240V~50Hz
REF: 447249
0-24V D.C
RE
D
BL
AC
K
WH
IT
E
L
~ N
S ELV Supply
N
+
-
24V
0V
8V
+
RED
W HITE
BLAC K
220-240V~50Hz
R EF: 447249
0-24V D .C
RE
D
BLACK
WH
IT
E
Power supply unit
Located here