Vent-Axia VA140/150KP Installation and wiring instructions

Summary of VA140/150KP

  • Page 1

    Stock ref.No va140/150kp 140120c va140/150kt 140220c va140/150khp 140320c va140/150kht 140420c va140/150 range axial kitchen fans installation and wiring instructions 220-240v~50hz read in conjunction with illustrations please save these instructions.

  • Page 2

    2 [a] [b] [c] wall kit window kit [e] [g] [f] [f] [d] [h] [i] [g] [j] installation and wiring instructions for the va140/ 150 kp, kt, khp, kht extract fan. Important: read these instructions before commencing the installation do not install this product in areas where the following may be present or...

  • Page 3

    3 fixing holes a installation. Panel mounting 1. Cut a 152mm hole through the panel. (suitable for existing holes up to 185mm ). 2. Remove the indoor grille [a]. Loosen the screw (top middle) of the grille, to release front grille gently lever the grille downwards away from the inner cover [b]. 3. R...

  • Page 4

    4 1 phase supply (220-240v 50hz). Switched fused spur fuse ~ l n fan l n fig. 2. B. Wiring. Warning: the fan and any ancillary control equipment must be isolated from the power supply during the installation / or maintenance. 1. Select and follow the appropriate wiring diagram (fig. 3-6). 2. Check a...

  • Page 5

    5 fig. 4. Va140/ 150kt timer model. Timer adjustment. The overrun time period is factory set to approximately 15 minutes. The overrun time period may be adjusted at installation from 5-30 minutes, by altering the adjuster on the fan pcb. Before adjusting the timer, switch off the mains supply. 1. Re...

  • Page 6

    6 1 phase supply (220-240v 50hz). Switched fused spur fuse ~ l n humidity adjuster. Fan l n fig. 5. Va140/ 150khp humidity model. Humidity set-point adjustment. The fan’s humidity set-point is factory set to switch the fan on at approximately 72%rh. The sensitivity may be adjusted at installation fr...

  • Page 7

    7 humidity and time set-point adjustment. The fan’s humidity set-point is factory set to switch the fan on at approximately 72%rh. The sensitivity may be adjusted from 65%rh - 90%rh, by altering the adjuster on the fan pcb. The overrun time period is factory set to approximately 15 minutes. The over...

  • Page 8

    8 head office: fleming way, crawley, west sussex, rh10 9yx. Uk national call centre, newton road, crawley, west sussex, rh10 9ja sales enquiries: tel: 0844 8560590 fax: 01293 565169 technical support: tel: 0844 8560594 fax: 01293 532814 for details of the warranty and returns procedure please refer ...