Vents KSB 100 User Manual - Warning!

Manual is about: SOUND-INSULATED FAN KSB series

Summary of KSB 100

  • Page 1

    Ksb sound-insulated fan ksb user’s manual v51en-04.Indd 1 23.10.2015 9:57:20

  • Page 2

    2 ksb contents safety requirements ............................................................................................... 3 introduction .............................................................................................................. 5 purpose ....................................

  • Page 3: Warning!

    3 www.Ventilation-system.Com • read the user’s manual carefully prior to installing and operating the unit. • fulfil the user’s manual requirements as well as the provisions of all the applicable local and national construction, electrical and technical norms and standards. • the warnings contained ...

  • Page 4

    4 ksb unit operation safety precautions do not touch the unit controls with wet hands. Do not carry out the installation and maintenance operations with wet hands. Do not wash the unit with water. Protect the electric parts of the unit against ingress of water. Use the unit only for its intended pur...

  • Page 5

    5 www.Ventilation-system.Com the user’s manual consisting of the technical details, operating instructions and technical specification applies to the installation and mounting of the sound-insulated fan vents ksb (hereinafter referred to as «the unit»). Introduction purpose delivery set the fan is i...

  • Page 6

    6 ksb technical data vents ksb 100 s m u1 r k1 insulation _ - pu foam insulation. K1 - mineral wool insulation. Connection to power mains _ - equipped with a terminal box. R - equipped with a power cord with iec c14 plug. R1 - equipped with a power cord with a wall socket plug (depending on the coun...

  • Page 7

    7 www.Ventilation-system.Com model dimensions [mm] weight [kg] Ød b b1 h l l1 l2 ksb 100 99 322 280 192 447 380 350 5.4 ksb 125 124 322 280 192 447 380 350 5.4 ksb 150 149 352 310 212 477 410 380 6.4 ksb 160 159 352 310 212 477 410 380 6.4 ksb 200 199 432 368 287 588 506 480 10.0 ksb 200c 199 432 36...

  • Page 8

    8 ksb the fan casing is made of galvanized steel sheets internally lined with heat- and sound-insulation layer. The round spigots are rubber sealed for airtight connection to the air ducts, fig. 2. The fan is equipped with a bipolar asynchronous motor with an external rotor and a centrifugal impelle...

  • Page 9

    9 www.Ventilation-system.Com mounting and setup the inline fan ksb is designed for direct connection to round air ducts. The casing has mounting brackets to facilitate the fan installation. In case the fan is mounted on flexible joints attach the fan to a structural unit by means of supports, suspen...

  • Page 10

    10 ksb connection to power mains disconnect the fan from power supply prior to any electric installation operations. Installation shall only be performed by a professional electrician qualified for unassisted operations with electrical installations up to 1000 v after careful study of the present us...

  • Page 11

    11 www.Ventilation-system.Com fig. 5 x1 l pe n l pe n ~230 v 50-60 hz qf ~230 v 50-60 hz qf - automatic circuit breaker qf - automatic circuit breaker ~230 v 50-60 hz terminal box fan fan x1 - terminal block qf is an automatic circuit breaker. Not included in the delivery set. Fig. 4 1. 2. V51en-04....

  • Page 12

    12 ksb control fig. 6 min max 21 22 23 24 25 26 27 28 29 t c 30°c 20°c speed control knob thermostat control knob thermostat operating light indicator depending on the configuration the fan may be equipped with an electronic temperature and speed control unit, fig. 6. Ksb fan is a perfect solution f...

  • Page 13

    13 www.Ventilation-system.Com example of the temperature sensor feedback delay: initial conditions: rated rotation speed is 60 % of the maximum speed. Set temperature point is +25 °c. Air duct temperature is +20 °c. Fan impeller rotation speed is 60 %. Air duct temperature increases. Fan impeller ro...

  • Page 14

    14 ksb air duct temperature increases, reaches +25°c and continues to grow after the timer stops, the motor switches to the high speed 100%. After the speed switch the timer starts 5 minutes countdown. Thus, in the timer delay pattern the delay timer activates each time the fan speed changes. Techni...

  • Page 15

    15 www.Ventilation-system.Com troubleshooting possible problems and troubleshooting problem possible reasons troubleshooting the fan does not get started. No connection to power supply. Make sure that the fan is properly connected to the power mains and make any corrections, if necessary. Jammed mot...

  • Page 16

    16 ksb manufacturer’s warranty the manufacturer hereby warrants warranty period of the product for 24 months after the retail sale date provided the user’s observance of the transportation, storage, mounting and operation regulations. Should any malfunctions occur in the course of the unit operation...

  • Page 17

    17 www.Ventilation-system.Com acceptance certificate seller information seller address phone number e-mail purchase date this is to certify acceptance of the complete fan delivery with the user’s manual. The warranty terms are acknowledged and accepted. Customer’s signature seller’s stamp unit type ...

  • Page 18

    18 ksb installation certificate the sound-insulated fan ksb has been connected to power mains pursuant to the requirements stated in the present user's manual. Company name address phone number installation technician's full name installation date: signature: installation technician’s company seal t...

  • Page 19

    19 www.Ventilation-system.Com warranty card unit type sound-insulated fan model vents ksb______________ serial number manufacture date purchase date warranty period seller seller’s stamp v51en-04.Indd 19 23.10.2015 9:57:28.

  • Page 20

    V51en-04 v51en-04.Indd 20 23.10.2015 9:57:29.