Venue Lighting Effects LED PAR64 User Manual - Dmx Values and Functions
leD PAR 64 instRuction mAnuAl
DMX VALUES AND FUNCTIONS
Channel 1, 2, and 3 will not work when Channel 4 is being used. When units are daisy chained together
in DMX Mode, Channels 1, 2, and 3 must be “OFF” for units to sync together when using Channel 4.
When the value of Channel 6 is between 32 and 127, you must be using Channels 1, 2, or 3, or all
three combined.
When using Channel 6, Channel 5 will control the speed of the color changing.
PHOTOMETRIC CHART
Page 6
LED PAR 64
P64LED
R(51)
49
2.5
0.8
0.4
0.2
LUX
G(49)
201
10.4
3.0
1.5
0.9
LUX
B(51)
11.1
0.8
0.3
0.2
0.1
LUX
RGB(151) 214
11.3
3.1
1.5
0.9
LUX
Distance
1
5
10
15
20
Meter
3eam Diameter 0.5
2.7
5.4
8
10.7
Meter
10
8
6
4
2
0
2
4
6
8
10
30˚
Channel Value
Function
1 0 - 255 RED
0% 100%
2 0 - 255 GREEN
0% 100%
3 0 - 255 BLUE
0% 100%
4 8 - 255 COLOR MACRO
5 0 - 15 NOTHING
16 - 255 STROBING
6 0 - 31 NOTHING
DIMMING CONTROL
32 - 63 DIM BRIGHT
64 - 95 BRIGHT DIM
96 - 127 DIM BRIGHT DIM
128 - 159 COLOR MIXING
160 - 191 3 COLOR CHANGE
192 - 223 7 COLOR CHANGE
224 - 255 SOUND ACTIVE