Verbatim CP005E User Manual - page 9
9
NSF/ANSI Standard 42 – Aesthetic Effects
Influent Challenge Concentration
Filter Effluent
Percentage
Reduction
Reduction
Requirement
Substance
Actual
NSF Target
Average
Maximum
Overall
Chlorine taste
and odor
2.1 mg/L
2.0 mg/L + /-10%
0.05 mg/L
0.05 mg/L
97.5%
≥ 50%
NSF/ANSI Standard 53 – Health Effects
Influent Challenge Concentration
Filter Effluent
Percentage
Reduction
Reduction
Requirement
Substance
Actual
NSF Target
Average
Maximum
Overall
Cysts
370,000/L
minimum 50,000/L
1.8 /L
7 /L
>99.99%
99.95%
Influent Challenge Concentration
Filter Effluent
Percentage
Reduction
Maximum
permissible
product water
concentration
Substance
Actual
NSF Target
Average
Maximum
Overall
Turbidity
10.5 NTU
11± NTU
ND (0.1)
0.1
99.1%
0.5 NTU
if any. All returns require a dated original proof of purchase and a letter explaining the problem. Verbatim will not be
responsible for items returned in improper packaging. Replacement Products shall be new or like new in performance
and shall be warranted for the remaining duration of the warranty term of the non-conforming Products. All replaced
Products shall become the property of Verbatim. Any claims of defects not made within the warranty period shall be
deemed waived by Customer.
9. Specifications and Performance
Model# CP005E
Model# CP005E
Maintenance according to the manufacturer’s instructions is critical for proper filter performance. Filter life should not
exceed 200 liters (52.83 gallons). If filtering time is notably increased, replace the filter earlier.
This system has been tested according to NSF/ANSI 42 and 53 standards by NSF International for reduction
of the substances listed above. The concentration of the indicated substances in water entering the system was
reduces to a concentration less than or equal to the permissible limit for water leaving the system, as specified in
NSF/ANSI 42 and 53.
The system conforms to NSF/ANSI 42 and 53 for specific performance claims as verified and substantiated by test
data. While testing was performed under standard laboratory conditions, actual performance may vary.
The use of this system shall comply with applicable state and local laws.
Please contact Verbatim technical support for details of where replacement filters are available.
1-800-538-8589 M-F 8:00am - 9:00pm EST www.verbatim.com/support
Working pressure (min/max): N/A
Capacity: 52.83 gallons (200 liters)
Service flow rate: N/A
Filtered water temperature (min/max): 33° F /95° F (1° C /35° C)
Electrical requirements: none