Verine Fontana Compact BF User Instructions

Manual is about: LOG EFFECT BALANCED FLUE ROOM HEATER

Summary of Fontana Compact BF

  • Page 1

    Fontana compact bf log effect balanced flue room heater user instructions these instructions should be read by the user before operating the appliance and retained for future reference model no. Nhbl**rn is for use on natural gas (g20) at a supply pressure of 20 mbar in g.B. / i.E. ** denotes trim &...

  • Page 2

    Installation information conditions of installation it is the law that all gas appliances are installed only by a competent (e.G. Gas safe registered) installer, in accordance with the installation instructions and the gas safety (installation and use) regulations 1998 as amended. Failure to install...

  • Page 3

    About your new fontana compact bf room heater the verine fontana compact log effect balanced flue room heater incorporates a unique and highly developed fuel bed which gives the realism of a loose log layout combined with realistic flames and glow. The use of durable hard ceramic material in the con...

  • Page 4

    The fuel bed remains hot for a considerable period after use and sufficient time should be allowed for the fire to cool before cleaning etc. The fire must only be operated with the fascia as supplied, in position. Operating the fire this appliance is designed so the pilot burner runs constantly, and...

  • Page 5

    Lighting the main burner (via the remote handset) with the pilot burner established it is possible to light the main burner and adjust the gas rate between high and low with the remote control handset. Press the “up” button to light the main burner and adjust the heat input to the maximum setting. (...

  • Page 6: Cleaning

    Note : this appliance is designed to work safely and effectively during adverse weather conditions. However, during such times flame disturbance may be noticed. This is normal and does not effect or impair the safety of the appliance. Cleaning warning : before attempting any cleaning operation ensur...

  • Page 7: Cleaning The Glass Panel

    Cleaning the glass panel to clean the glass panel, first ensure that the fire is cool, please note that the glass panel will remain hot for a considerable period when the fire has been switched off. To remove the glass panel, follow the instructions below for removal and re-fitting. The glass panel ...

  • Page 8

    Removal & re-fitting of the fuel-bed logset a) the gravel material should then be first layed around the base of the combustion chamber as shown below in fig. 5, leaving the rear section as shown to allow the fitting of log “a” fig. 5 b) place the largest log “a” centrally onto the fuel-bed support ...

  • Page 9

    C) fit log “b” into position on right hand side of the fuel-bed base log “a”as shown below in fig. 7, using the groove in log “a” as a guide for placement, and locate the in slot the fork of the log into the upturn in the base plate. Fig. 7 d) fit log “c” into position on left hand side of the fuel-...

  • Page 10

    D) fit log “d” into position on left hand side of the fuel-bed base log “a”as shown below in fig. 9, using the groove in log “a” as a guide for placement, and locate the slot in the log into the upturn in the base plate. Fig. 9 e) fit log “e” into position at centre of the fuel-bed base log “a”as sh...

  • Page 11

    Warning : use only the logs supplied with the fire. When replacing the logs remove the old logs and discard them. Fit a complete set of logs of the correct type. Do not fit additional logs or any logs other than a genuine replacement set. To ensure that the release of fibres from these r.C.F (refrac...

  • Page 12

    Removal and re-fitting of the “fontana compact” fascia to the product. A) the trim is supplied in 3 pieces, the rear panel, the front panel and the stainless steel trim insert. Fix the rear panel to the wall with via the 4 screw holes with screws / rawlplugs. Note : the flange of the rear panel must...

  • Page 13

    User replaceable parts the only user replaceable parts on this fire are the fuelbed / coal form, and the handset / ultrasonic receiver batteries, which may be replaced as described below. Replacement of any other parts must be carried out by a competent person such as a gas safe registered gas insta...