Verine NPFC/P00T/MN Installation, servicing and user instructions manual - page 12
12
ELECTRICAL CONNECTION TO MAINS SUPPLY
1
It is recommended that the electrical connection to the mains supply is made via either
a 3A fused spur or an unswitched three-pin socket and 3A fused plug.
2
The appliance is supplied with 2.5 metres of three-core mains cable pre- wired. This
should be routed to the power point as inconspicuously as possible - i.e. chased into the
plaster.
3
The electrical connections to the switches are all pre-wired and the only other
connections required are in the fan box, which are explained in pages 9-10 of these
instructions.
LIGHTING THE APPLIANCE (See Figures 12 and 13)
Note: This system operates with a permanent pilot. The pilot light must be established
before the electrical switches are operated.
1
Turn the isolating gas cock on and switch on the electrical mains supply.
2
Push in and turn the control knob anti-clockwise to thePILOTposition. As the knob is
turned the piezo unit will be heard to operate and a spark will be produced at the pilot
electrode.
Note: If the pilot does not light, keep the knob depressed in the PILOT position for a
short period of time - this will purge any air in the system. Once the air has been
purged, repeat step 2 as above.
3
Keep the knob depressed for 10 - 15 seconds and the release. The pilot flame should
remain alight.
4
If the pilot flame goes out, repeat the process, holding down the control knob for a
slightly longer period.
5
Depress the control knob slightly and turn anti-clockwise to the ON position.
6
Press the ON/OFF switch on the control panel on the side of the fire to the ON position.
7
Press and release the START switch. The fan will start and after a short period, during
which the system makes its safety checks, the first solenoid valve will open and the
main burner will light at the low rate.
8
To set the main burner to the maximum rate the high/low switch on the side of the
appliance should be switched to the HIGH position.
9
To turn the pilot off, press in and turn the knob fully clockwise to the PILOT position.
To turn the fan off press the ON/OFF switch to the OFF position. Ensure that the fire
has turned off.
FIGURE 13
FIGURE 12