SECTION 3
GENERAL REQUIREMENTS (EIRE)
This appliance must be installed by a competent person in
accordance with and defined by the Standards Specifica-
tion (Domestic Gas Installation) Declaration (I.S. 813).
3A.1
RELATED DOCUMENTS
The installation of this boiler must be in accordance with the
relevant requirements of the local building regulations, the
current ETCI National Rules for Electrical Installations and
the bylaws of the local water undertaking. It should be in
accordance also with any relevant requirements of the
local and/or district authority.
3A.2
LOCATION OF APPLIANCE
The appliance may be installed in any room or internal
space, although particular attention is drawn to the require-
ments of the current ETCI National Rules for Electrical
Installations, and I.S. 813, Annex K.
When an appliance is installed in a room or internal space
containing a bath or shower, the appliance or any control
pertaining to it must not be within reach of a person using
the bath or shower. The location chosen for the appliance
must permit the provision of a safe and satisfactory flue and
termination. The location must also permit an adequate air
supply for combustion purposes and an adequate space
for servicing and air circulation around the appliance.
Where the installation of the appliance will be in an unusual
location special procedures may be necessary, refer to I.S.
813 for detailed guidance on this aspect. A compartment
used to enclose the appliance must be designed and
constructed specifically for this purpose. An existing com-
partment cupboard may be utilised provided that it is
modified to suit. This appliance is not suitable for external
installation.
3A.3
GAS SUPPLY
The gas meter - as supplied by the gas supplier - must be
checked to ensure that it is of adequate size to deal with the
maximum rated input of all the appliances that it serves.
Installation pipes must be fitted in accordance with I.S. 813.
Pipe work from the meter to the appliance must be of
adequate size. Pipes of a smaller size than the appliance
gas inlet connection must not be used. The installation
must be tested for soundness in accordance with I.S. 813.
If the gas supply serves more than one appliance, it must
be ensured that an adequate supply is maintained to each
appliance when they are in use at the same time.
3A.4
FLUE SYSTEM
The terminal should be located where the dispersal of
combustion products is not impeded and with due regard
for the damage and discoloration that may occur to building
products located nearby. The terminal must not be located
in a place where it is likely to cause a nuisance (see I.S.
813). In cold and/or humid weather, water vapour will