Voltec 10-00474 Owner's Manual - page 9
- 9 -
cables.
z Adjust the orientation of the inverter television, antenna and cables.
z Maximize TV signal strength by using a better antenna and use
shielded antenna cable where possible.
c) Reference Chart
PROBLEM CAUSE
SOLUTION
Battery is defective
Replace battery
Blown fuse
Check and replace fuse
No power, no
indicator.
Lose cable connections
Check the connection to the
battery. Tighten as required.
AC products connected are
rated at more than the
Wattage load of the
inverter; overload
shutdown has occurred.
Reduce load.
AC products at less than
the Wattage load of the
inverter, but high starting
surge has caused overload
shutdown.
Use a product with starting
surge power within the
inverter’s capability.
The voltage input from the
DC power source is too
low (alarm is sounding).
Charge the power source
battery
The red LED
indicator
illuminates.
Inverter is overheated due
to poor ventilation and has
shut down.
Unplug inverter from DC
socket and allow to be
cooled for 15 minutes.
Remove objects covering
unit. Move the inverter to a
cooler place. Reduce load if
continuous operation is