User’s manual analyzer x3 & x6 r made in usa by: w & w manufacturing co. 3 minute battery analyzer ! W & w manufacturing co. 800 south broadway hicksville, ny 11801 in usa & canada: 800-221-0732 in n.Y. State: 516-942-0011 fax: 516-942-1944 e-mail: email@ww-manufacturing.Com website: http://www.Ww-m...
Table of contents features……………………………………………………………..4 specifications……………………………………………...............5 part overview…………………………………………………….…6 understanding the x3’s adapters cup………………….……….7 getting started …………………………………………....………8 quick test analysis………………………………………..……......9 cycle mode…………………………………….…...
Safety and operating environment always use a grounded ac outlet to power the analyzer x3 & x6. Keep the analyzer x3 & x6 at least one-foot away from any object to allow for proper do not analyze batteries outside the recommended temperature ranges. For good and (room temperature) is recommended. Al...
Of battery chemistries such as; lithium ion, lithium polymer, nickel cadmium and nickel metal hydride. Most mechanical shapes can be accommodated with a specially designed battery cup. See battery cup description for more information. Features analyzes, condition and charges nickel cadmium and nicke...
& x6 specifications x number of stations quick test: standard tests: batter y voltage charge/discharge current: maximum charge power x3 maximum discharge power: x3 power management chemistries charge and end of charge detection protocols: display: batter y adapters: data ports: line voltage: input c...
Rear view of analyzer x3 rear view of analyzer x6 analyzer x3 parts overview printer port printer port printer port printer port function buttons display serial port (printer) db9-male serial port (computer) db9-female adapter cups empty empty empty 1 2 3 6 impedance test impedance of a battery can ...
Understanding the analyzer x3’s and x6’s adapter cup the “adapter cup” allow different batteries to be serviced by the analyzer x3 and x6. Each “adapter cup” is made for a specific battery model. There are 5 memory locations (data profile locations) within each “adapter cup”. The first four profiles...
Getting started power up - connect the unit to the proper ac voltage and turn-on power using the switch located on the back of the unit. You are now ready to service a battery. . Placing the appropriate “adapter cup” in the analyzer will allow you to service an oem battery. The cup contains pre-stor...
This is an advanced proprietary algorithm capable of determining the health of a battery. Specially stored parameters allowing the analyzer x3 or x6 to identify a battery’s range of capacity and display: batt>60% or batt may require a charge of up to 10 minutes before performing the qt. Up to 3 atte...
Cycle mode the cycle mode will cycle a battery through a charge and discharge cycle, known as cycle (1). One could select, cycle 1, 2 or 3. By selecting cycle 1,2 or 3 all one would be doing is repeating the charge/discharge number to reflect the chosen cycle count. Cycle 2 and 3 are often used for ...