Wacker Neuson GS 12Ai Operator's Manual - Operation
of
48
Operation
GS 12Ai
31
wc_tx001589gb.fm
4.10
Stopping
4.10.1
Turn off and disconnect all tools and appliances attached to the
generator.
4.10.2
Place main circuit breaker in open position (e2).
4.10.3
Turn engine switch to “OFF” (b1).
4.10.4
Turn fuel valve off.
Note: To stop engine quickly in an emergency, turn engine switch to
"OFF".
4.11
Emergency Shutdown Procedure
Procedure
If a breakdown or accident occurs while the machine is operating,
follow the procedure below:
4.11.1
Stop the engine.
4.11.2
Turn off the fuel supply.
4.11.3
Disconnect tools from the machine.
4.11.4
Allow the machine to cool.
4.11.5
Contact the rental yard or machine owner for further instructions.