Waeco CF-35 Instruction Manual - 2.2

Summary of CF-35

  • Page 1

    M_81003 cf-18,cf-25,cf-35, cf-40, cf-50, cf-50dz, cf-60 aus compressor cooler instruction manual cf-40 ac cf-50 ac cf-50 acdz cf-60 ac cf-25 cf-18 cf-35 ac cf18-60_m_81003:powervac_pv-100 3/9/08 3:53 pm page 1.

  • Page 2: Contents

    3 coolfreeze please read this operating manual carefully before starting the device. Keep it in a safe place for future reference. If the device is handed over to another person, this operating manual must be handed over along with the device. Contents 1 notes on using the manual ......................

  • Page 3

    4 coolfreeze 1 4 2 3 1 12/24v dc cold freeze error power high 0 low temperature battery monitor 1 2 3 4 5 1 2 3 cf-25, cf-35, cf-40, cf-18 cf18-60_m_81003:powervac_pv-100 3/9/08 3:53 pm page 4.

  • Page 4

    5 coolfreeze on off set power up + down – error ° 1 3 4 5 6 7 2 1 2 1 4 7 12/24v dc 1 4 5 cf-25, cf-35, cf-40, cf-50, cf-60 cf-35, cf-40, cf-50, cf-60 cf-25 cf-35, cf-40, cf-50, cf-60 100-240v~ac fuse emergency override normal use 1 2 12/24v dc 3 4 6 cf18-60_m_81003:powervac_pv-100 3/9/08 3:53 pm pa...

  • Page 5

    6 coolfreeze 8 1 2 3 4 5 6 9 1 2 10 cf-50, cf-60 a b cf18-60_m_81003:powervac_pv-100 3/9/08 3:53 pm page 6.

  • Page 6: Notes On Using The Manual

    7 coolfreeze notes on using the manual 1 notes on using the manual the following symbols are used in this operating manual: caution! Safety instruction: failure to observe this instruction can cause personal injury or damage the device. Caution! Safety instruction: relating to a danger from an elect...

  • Page 7: 2.1

    8 coolfreeze safety instructions 2.1 general safety • caution – danger of electrocution! – when using the device on boats: if the device is powered by the mains, ensure that the power supply is protected with a ground fault interrupter circuit. • check that the voltage specification on the type plate...

  • Page 8: 2.2

    9 coolfreeze intended use 2.2 operating the device safely • caution – danger of electrocution! Do not touch exposed cables with your bare hands. This especially applies when operating the device from an ac mains. • before starting the device, ensure that the power supply line and the plug are dry. •...

  • Page 9: Scope Of Delivery

    10 coolfreeze function description 3 scope of delivery fig. 1 page 4, shows the scope of delivery. Item quantity description 1 1 cooler 2 1 connection cable for 12/24 vdc connection 3 1 (except cf-18, cf-25) connection cable for 100 – 240 vac connection 4 2 (except cf-18, cf-25) carrying handle, con...

  • Page 10: Function Description

    11 coolfreeze operation 5 function description the cooler can chill products, keep them cool as well as freeze them. A low maintenance, cfc-free refrigerant circuit with compressor provides the cooling. The extra strong cfc-free insulation and powerful compressor ensure especially fast cooling. The ...

  • Page 11: 5.1

    12 coolfreeze operation 5.1 operating and display elements cf-25, cf-35, cf-40 lock for lid: fig. 2 1, page 4. Cf-18 operating panel and connection socket (fig. 3 page 4): item description explanation 1 temperature temperature controller, cooling temperature at the end positions: cold: +10 ˚c (+50 ˚...

  • Page 12

    13 coolfreeze operation cf-25, cf-35, cf-40, cf-50, cf-60 operating panel (fig. 4 page 5) item description explanation 1 on switches the cooler on or off when the off button is pressed for between one and two seconds 2 power status indication led lights up green: compressor is on led lights up amber...

  • Page 13: 5.2

    14 coolfreeze operation 5.2 accessories if you want to operate the coolers cf-18 and cf-25 from the 240 v ac mains, be sure to use the rectifier waeco coolpower eps-816 (cf-18 only) or eps-817 (cf-18 and cf-25). 6 operation 6.1 before initial use note before starting your new cooler for the first time...

  • Page 14: 6.2

    15 coolfreeze operation selecting the temperature units – ºc or ºf cf-25, cf-35, cf-40, cf-50, cf-60 you can switch the temperature display between celsius and fahrenheit. This is how to do it: ➤ switch on the cooler. ➤ press the “set” button (fig. 4 4, page 5) twice. ➤ use the “up +” (fig. 4 6, pag...

  • Page 15: 6.3

    16 coolfreeze operation 6.3 connecting the cooler connecting to a battery (vehicle or boat) the cooler can be operated with 12 v or 24 v dc. Caution – danger of damaging the device! Disconnect the cooler and other consumer units from the battery before you connect the battery to a quick charging dev...

  • Page 16: 6.4

    17 coolfreeze operation cf-18 cf-18, cf-25 to operate the coolers cf-18 and cf-25 from the 220–240 v ac mains, use the optional accessory rectifier waeco coolpower eps-816 (cf-18 only) or eps-817 (cf-18 and cf-25). 6.4 using the battery monitor the device is equipped with a multi-level battery monito...

  • Page 17: 6.5

    18 coolfreeze troubleshooting (low) (med) (high) cf-25, cf-35, cf-40, cf-50, cf-60 ➤ switch on the cooler. ➤ press the “set” button (fig. 4 4, page 5) three times. ➤ use the “up +” (fig. 4 6, page 5) and “down -” (fig. 4 7, page 5) buttons to select the battery monitor mode. ➤ digital display will b...

  • Page 18

    19 coolfreeze technical data cf-18 ➤ slide the sliding switch (fig. 3 4, page 4) to “low” or “high” battery protection (see 6.4 “using the battery monitor” for suitable level). ✔ the “power” led is lit green. ✔ the cooler starts cooling the interior. ✔ when the cooling temperature has been reached, ...

  • Page 19: 6.6

    20 coolfreeze 6.6 setting the temperature cf-18 ➤ set the cooling temperature with the temperature controller (fig. 3 1, page 4). Cf-25, cf-35, cf-40, cf-50, cf-60 ➤ press the “set” button (fig. 4 4, page 5) once. ➤ use the “up +” (fig. 4 6, page 5) and “down -” (fig. 4 7, page 5) buttons to select ...

  • Page 20: 6.10

    21 coolfreeze ➤ take out the contents of the cooling device. ➤ if necessary, place them in another cooling device to keep them cool. ➤ switch off the device. ➤ leave the cover open. ➤ wipe off the defrosted water. 6.10 replacing the device fuse (240v) only cf-35, cf-40, cf-50, cf-60 caution – danger...

  • Page 21: 6.12

    22 coolfreeze 6.12 replacing the light bulb only cf-25, cf-35, cf-40, cf-50, cf-60 ➤ press the switch pin (fig. 10 2, page 6) downwards so that the transparent part (fig. 10 1, page 6) of the lamp can be removed at the front. ➤ replace the light bulb ensuring that: i) the led’s inside the bulb face ...

  • Page 22: Troubleshooting

    23 coolfreeze 9 troubleshooting fault device does not function, power led does not glow. The device does not cool (plug is inserted, “power” led is lit). The device does not cool (plug is inserted, “power” led flashes + digital display blank). The device does not cool (plug is inserted, “error” led fl...

  • Page 23: Technical Data

    24 coolfreeze 11 technical data cf-18 cf-25 cf-35 overall capacity: 18 litres 23 litres 31 litres connection voltage: 12/24 v dc and 100–240 v ac rated current: – 12 vdc: 3.1 a 6.8 a 6.0 a – 24 vdc: 1.9 a 3.0 a 3.0 a – 100–240 vac: – – 1.3 to 0.7 a cooling range: +10 ˚c to –18 ˚c (+50 ˚f to 0 ˚f) di...

  • Page 24

    25 coolfreeze test/certificates: – 73/23/eec – low voltage electrical equipment directive – 89/336/eec – emc directive – 95/54/eec versions and delivery options may vary due to technical modifications. This device is cfc-free. The coolant circuit contains r134a. Cf18-60_m_81003:powervac_pv-100 3/9/08 ...

  • Page 25

    26 coolfreeze cf18-60_m_81003:powervac_pv-100 3/9/08 3:53 pm page 26.

  • Page 26

    27 coolfreeze cf18-60_m_81003:powervac_pv-100 3/9/08 3:53 pm page 27.

  • Page 27

    28 coolfreeze aus nz internet http://www.Waeco.Com.Au http://www.Waeco.Co.Nz waeco western australia 9 hod way malaga wa 6090 phone: 1800 21 21 21 fax: (08) 9209 3577 waeco new zealand unit 15, 180 montgomerie road airport oaks, auckland 1701 phone: 0800 676 000 fax: (09) 256 0017 e-mail: info@waeco...