WAGNER LEGACY Manual - Failure Correction
7
FAILURE CORRECTION
If LEGACY should fail to function despite observance of all instructions, plea-
se proceed as described in the following steps :
1) It may occur that your LEGACY is ready for operation but it is covered by
another source of light. In this case, relocate the solar station.
2) Ensure that your LEGACY does not stand in the shade during the day.
3) Check the rechargeable battery for corrosion.
REMOVING / CHANGING THE RECHARGEABLE
BATTERY
• Turn the lens counter-clockwise by hand to separate the lens from the
lamp
c
.
• Detach the lens from the lamp
d
.
• Lay the lamp head down on the ground.
• Take off the two fastening screws on the cover of the rechargeable battery
and remove the cover of the rechargeable battery
e
.
• Remove the rechargeable battery to re-load it and/or exchange it
f
.
Re-assembly is accordingly conducted in the reverse order
ATTENTION!
Use Original Wagner rechargeable batteries only.
When exchanging the rechargeable battery, ensure that none of the
connections or wires are damaged.
Winterrise
We recommend storing your LEGACY in winter at temperatures below 0°C in
a frost-free location and re-erecting it in spring. The rechargeable battery can
be loaded with a commercial net charger.
Special Accessories
Rechargeable battery
Art. No. 1016701
GB