WAGNER MMI 1100 Instruction Manual - Introduction

Manual is about: Moisture Meter

Summary of MMI 1100

  • Page 1

    Moisture meter instruction manual wagner model mmi 1100 1-800-634-9961.

  • Page 2: Table Of Contents

    2 table of contents introduction..........................................................................................................................3 instructions - mmi 1100 ......................................................................................................4 taking measureme...

  • Page 3: Introduction

    3 introduction congratulations! You have purchased one of the most accurate moisture measurement instruments for wood in the world. Using patented electromagnetic wave technology, hand-held moisture meters from wagner meters have been proven by universities and institutes worldwide to provide superi...

  • Page 4

    4 operational instructions — mmi 1100 on/off button: when the meter is off, momentarily pressing and releasing this button will cause the meter to turn on, and briefly display the firmware version, then enter measurement mode. When the meter is in measurement mode, and the on/off button is momentari...

  • Page 5

    5 mode button: the mode button changes the operation mode. If the meter has been turned off, the mode always defaults to mode 1 after turning power back on. View/change modes overview: when the meter is turned on, pressing the mode button will cause the current mode to be displayed on the screen. Mo...

  • Page 6

    6 mode 3 = review mode a sample review mode screen is depicted in figure 3. When review mode is first selected, the memory location of the most recently viewed mc reading is displayed momentarily (see figure 2, previous page). The mc reading in that memory location will then be displayed momentarily...

  • Page 7

    7 if there is no stored low reading, the display will indicate: mode 5 = view high reading. Selecting mode 5 will cause the display to show “hi” (see figure 5) momentarily followed by the highest reading stored in memory. After momentarily showing the highest reading, the display will revert back to...

  • Page 8: Taking Measurements

    8 mode 7 = erase data when the erase data mode is selected, it will first indicate how many memory locations are currently used. The erase data mode can then be used to erase all of the stored mc readings. The display will first show the erase screen as shown in figure 7a. The erase screen shows how...

  • Page 9: Mmi 1100 Features

    9 taking measurements continued… additional meter corrections may be necessary if you are measuring raft wood (salt water permeated), or lumber treated with cca, acq or any other treatment with metallic or other components that might bias the moisture readings. 4 mmi 1100 features auto-shutdown: the...

  • Page 10

    10 mmi 1100 meter specifications size: length 4 9 / 16 inches width 2 3 / 4 inches height 1 1 / 16 inches scanning area: length 2 1 / 2 inches width 1 1 / 2 inches scanning depth: 3 / 4 inch weight: 0.37 pounds power: 9 volt alkaline or ni-cad rechargeable auto power shut down: 60 seconds measuremen...

  • Page 11: Fcc Compliance Statement

    11 fcc compliance statement this equipment has been tested and found to comply within the limits for a class b digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment ge...

  • Page 12: Warranty

    12 warranty wagner meters warrants this product against defects in material and workmanship for seven (7) years from the date of purchase 5 , subject to the following terms and conditions: wagner meters’ liability under this warranty shall be limited, at wagner meters’ option, to the repair or repla...

  • Page 13: Repair Service

    13 repair service in the event of damage, failure, or if the unit requires re-calibration, contact wagner meters technical services department at www.Wagnerrepairs.Com or by phone for complete shipping information. The values stored in memory may be lost in the event that the meter is sent in for re...