Waldorf RN8100G Installation And Operation Manual - page 26
Gas Conversion and Specifications
24
- United Kingdom:
Category:
II
2H3P.
Flue Type:
A
1.
(*)
Measure Burner operating pressure at target top hob manifold test point with target top
burner (Inner and Outer ring) operating at full setting. Operating pressure is ex-factory set,
through appliance regulator and is not to be adjusted, apart from when carrying out gas
conversion, if required. (Refer to details in ’Gas Conversion’ section for information).
Natural Gas (G20)
Propane (G31)
Main Burner Injector (Inner Ring)
Ø 1.70mm
Ø 1.10mm
Main Burner Injector (Outer Ring)
Ø 2.60mm
Ø 1.55mm
Pilot Burner Injector
0.35 0.25
Burner Aeration Screw X (Inner)
25mm 20mm
Burner Aeration Screw Y (Outer)
28mm 25mm
Low Fire Adjustment
2½ turns out (ccw)
1¾ turn out (ccw)
Burner Operating Pressure (*)
9.9 mbar (*)
26.8 mbar (*)
Gas Regulator Cap Screw