WANDERS DANTA 1100 Installation, Servicing And User Instructions Manual

Summary of DANTA 1100

  • Page 1

    Danta installation, servicing and user instructions 500 - 800 - 1100 - 1400 - koto includes front, corner, bay and room divider ie gb this appliance has been tested and certified for other counties (see technical data). However to install appliance in other countries, modification of the appliance a...

  • Page 4

    4 1. General notes this wanders gas appliance is a high efficiency, balanced flue live fuel effect appliance. It provides radiant and convected heat using the latest burner technology. As well as having a variable heat output, these fires also utilise a special control system that allows the applian...

  • Page 6

    6 • the remote handset has 4 buttons; these will perform all operations of the fire. • always leave the dial on the gas control valve set to "on", the "man" position is only for servicing and emergency use if the handset is misplaced, or the battery fails. • with each successful button press of the ...

  • Page 8

    8 3. Installation instructions before commencing installation, confirm that the details on the appliance data plate correspond to the local distribution conditions, gas type and pressure to which the appliance is to be installed. Ensure that gas supply and supply pipe is capable of delivering the re...

  • Page 10

    10 appliance a min b min c min d min e min f min g min g2 min h min danta 500 front 515 375 650 490 195 700 n/a n/a n/a danta 500 bay n/a 375 555 490 195 700 355 355 n/a danta 500 corner n/a 375 600 490 195 700 355 n/a 515 danta 800 front 815 375 850 490 195 700 n/a n/a n/a danta 800 bay n/a 375 855...

  • Page 12

    12 3.3.4.B combustible mantel/side wall – top view a a fireplace opening a min. 150 (6") between edge of opening and wall 25 (1") 50 (2") 75 (3") 100 (4") fireplace opening face of finished wall area denotes allowable location for combustible mantel detail a wall cement board minimum thickness 12mm ...

  • Page 14

    14 3.4.5 terminal locations dimension terminal position distance (mm) a* directly below an opening, air brick, opening window etc. 600 b above an opening, air brick, opening window etc. 300 c adjacent to an opening, air brick, opening window etc. 400 d below gutters, soil pipes or drain pipes 300 e ...

  • Page 16

    16 3.4.7 vertical roof vent termination c31 flue sizing: danta 500: Ø100/150 connector on appliance,Ø100/150 to be used throughout. Flue terminal: Ø100/150 part no. Ink.4335 danta 800, 1100, 1400 & koto: Ø130/200 connector on appliance,Ø130/200 to be used throughout. Flue terminal: Ø130/200 part no....

  • Page 18

    18 restrictor 1-3m 35mm restrictor 3-8m 50mm 0-1m no restrictor 8-11m 60mm restrictor maximum vertical flue for danta 1100 (& koto) and flue restrictor selection 200/130 spigot on appliance 200/130 - 150/100 reducer onto spigot, 150/100 flue used there after. 35mm restrictor 35 50mm restrictor 50 60...

  • Page 20

    20 3.4.8 typical installations roof vent termination c31.

  • Page 22

    22 3.5.1 danta 500 3.5.2 danta 800 used logs: b - d - d - g (see page 26 for additional information) used logs: a - d - d - g - g - e - f (see page 26 for additional information).

  • Page 24

    24 3.5.4 danta 1400 & koto used logs: a - d - d - g - g - e - f - h - h (see page 26 for additional information).

  • Page 26

    26 3.6 commissioning the appliance 3.6.1 pilot ignition check 1. Ignite the pilot light as described in the user instructions 2. Check that the pilot fl ame stays alight 3. Extinguish the pilot light 3.6.2 main burner check 1. Ignite the pilot light as described in the user instructions 2. Turn on t...

  • Page 28

    28 4.3 spare parts part description partnumber for danta 500 partnumber for danta 800 partnumber for danta 1100 partnumber for danta 1400 partnumber for koto glass (front) gla.00.0770 gla.00.0750 gla.00.0720 gla.00.0700 gla.00.0798 glass (side) gla.00.0730 n/a glass (back) gla.00.0780 gla.00.0760 gl...

  • Page 30

    30 5.2 technical data product identification number: • 0359co1364 for danta, • 0359cp1411 for koto 5.2.1 danta 500 gas type g20 g20/g25 g25/g25.3 g20/g25 g30/g31 g31 i2h, i2e i2e+ i2l/i2ek i2ell i3b/p (30/50) i3+ i3p (37/50) i3p (30) supply pressure mbar 20 20/25 25 20 30/50 28-30/37 37/50 30 nomina...

  • Page 32

    32 6. Electric wiring thermocouple interuptor g 60- zu f1 0 re d 8 wired cable g 6r -c 5 cable thermocouple interuptor - receiver receiv er g 6r -r 4au ignition cable 4m m ,10 00m m th er m ocouple g as valve m er tik m ax itr ol g v 6 0 yellow ma gn etic valve gv -s 60 c/ 12.

  • Page 34

    34.

  • Page 35

    Garantiebewijs / guarantee certificate / certificat de garantie / garantieschein wanders fires & stoves amtweg 4 7077 al netterden the netherlands t: +31 (0) 315 - 386 414 f: +31 (0) 315 - 386 201 e: service@wanders.Nl i: www.Wanders.Com model / model / modèle / modell serienummer / serial number nr...

  • Page 36

    Wanders fi res & stoves amtweg 4 7077 al netterden the netherlands tel: +31 (0)315 - 386 414 fax: +31 (0)315 - 386 201 info@wanders.Nl www.Wanders.Nl @wanders_fi res www.Facebook.Com/wandersfi resstoves type- en zetfouten voorbehouden. Wanders fi res & stoves is een onderdeel van de wanders groep © ...