WANDERS Marvic MF Cassette Instructions For Use Installation And Servicing - page 9
9
Lighting the appliance
For best results set air controls
primary air open and air wash
completely open
Place firelighters and two hands full
of dry kindling wood on the grade
Light the firelighters,
Leave the door slightly open as the
fire establishes and the glass warms
to avoid buildup of condensation.
after several minutes the fire bed is
dying back at this point you place
lager pieces of wood on the fire approximately 1 kg leave the air controls unaltered when
these logs are well alight place two more logs onto the fire approximately 1,4 kg the air
controls and the door being in the same position as before after about 20 minutes from the
start close the door and primary air control.
Do not overload the fire ensure that the top of the logs are no higher than and do not obstruct
the rear holes
Close the door do not leave the door open as this could over-fire and damage the appliance.
Refueling
after refueling set the door on the
latch but not closed. the primary
air set fully open and the
secondary air set in the required
position after 5 minutes when the
logs are burning well close the
door and the primary air supply.
You can close the grate by using the tool that is supplied with the stove
Close the Primary air control and use the Air wash to control the burn rate when appliance is at
operating temperature,
Wood burns best on a bed of ash.
Burn new logs at high output for a few minutes before adjusting the Air wash control. Refuel little and
often for clean, burning.
When in use, burning the appliance at high output for a short period also reduces tars and soot.