Warmington Gas Nouveau SN 1100 Installation Instructions And Service Manual - page 16
23 April 2018
Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notifi-
All Dimension are in mm……. Copyright on all products and Specifications ©
16
IMPORTANT NOTES:
* Inlet Pressure not to exceed 4.0KPa
GAS SPECIFICATIONS Tested to current gas standards
NOTE : All Test Pressures are tested by a Independent Test Lab
MODLE
SG 700
SG 780
SG 900
SG 1100
LPG
Nominal Pressure kPa
2.75 kPa
2.75 kPa
2.75 kPa
2.75 kPa
Nominal Injector Size mm
2 X 1.1mm
2 X 1.2mm
2 X 1.3mm
2 X 1.4mm
Burner Pressure High kPa
2.5
2.5
2.5
2.5
Burner Pressure Low kPa
0.75
0.75
0.75
0.75
MJ/h
29
38
42
50
Falme Effect Output Only
Effect
Effect
Effect
Effect
Supply Pipe Size dia—min
3/8”
3/8”
1/2”
1/2”
Natural Gas
Nominal Pressure kPa
1.5 kPa
1.5 kPa
1.5 kPa
1.5 kPa
Nominal Injector Size mm
2 X 1.8mm
2 X 2mm
2 X 2.2mm
2 X 2.4mm
Burner Pressure High kPa
1
1
1
1
Burner Pressure Low kPa
0.3
0.3
0.3
0.3
MJ/h
35
41
48
60
Flame Effect Output Only
Effect
Effect
Effect
Effect
Supply Pipe Size dia—min
3/8”
1/2”
1/2”
1/2”
Lab. Test No
GL 923
GL 900
GL 834
GL 876
Lab. Test Dates
20/04/2010
26/02/10
26/06/09
24/12/09
ESS Declaration No:
1149420106
1149520106
1149720106
1149820106
OPERATION OF YOUR WARMINGTON GAS NOUVEAU FIRE (SG ONLY)
Your Fire must be Installed and Tested by a suitably qualified Gasfitter prior to use.
To light:
Open Burner Grate Front Cover by pulling it towards yourself.
Depress the Manual Ignition Switch and hold in the 'PILOT' position for 3-5 seconds. (This may take some time for the Gas to come through to the
Pilot-3 Flame)
Strike the Manual Ignition Switch by turning to the 'STAR' position, maintaining the Switch in a Depressed State ; (repeat steps 2 & 3 if necessary).
Once the Pilot Flame is lit, hold this position for 3-5 seconds, release from the depressed state before setting the flame control to full, it may take 3-5
seconds for the Burner to Light .
If a Solenoid is fitted to a SG Burner the Pilot Flame should stay on at all times with the Manual Ignition
Switch set to the desired High or Low Flame setting, unless you turn it Off/On at the Ignition Switch
manually. Once the Ignition Switch is set you can turn the Solenoid Off/On at your wall switch to allow
gas into the Burner.
Once the Flame Bed is established, set the Flame Control to the desired level & close cover.
To shut down:
Open Burner Grate Front Cover by pulling it towards yourself.
Turn Manual Ignition Switch to 'PILOT'. Flame bed will extinguish.
Pilot light may be extinguished by switching Manual Ignition Switch to 'OFF' before closing cover.