  • Page 1

    17 october 2014 all dimension are in mm………….Copyright © 1 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. Studio stove visit www.Warmington.Co.N z for spec’s, dwg’s and pdf uploads of fires fire, flue system and...

  • Page 2: Www.Warmington.Co.Nz

    17 october 2014 all dimension are in mm………….Copyright © 2 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. Manufactured by: warmington industries ltd - po box 58652 botany 2163, auckland nz model: ……studio stove ...

  • Page 3

    17 october 2014 all dimension are in mm………….Copyright © 3 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. Description cabinet width a 400 cabinet depth b 520 cabinet height c 820 flue diameter d 150 to flue cent...

  • Page 4

    17 october 2014 all dimension are in mm………….Copyright © 4 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. Description 1. 2. 3. To wall behind i 325 250 100 to wall side j 325 325 100 to flue centre (back) k 448 ...

  • Page 5

    17 october 2014 all dimension are in mm………….Copyright © 5 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. Step : 1 fitment & removal of baffle step : 2 step : 3 step : 4 step : 5 step : 6 remove ash & studio bri...

  • Page 6

    17 october 2014 all dimension are in mm………….Copyright © 6 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. Note: wet back can not be fitted to fires that are installed in any area that falls under clean air regul...

  • Page 7

    17 october 2014 all dimension are in mm………….Copyright © 7 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. Flue system installation guide minimum flue height flue height 3600 measured from top of fire c + 3600 fl...

  • Page 8: 3D View

    17 october 2014 all dimension are in mm………….Copyright © 8 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. Flue height minimum details the flue exit is to comply to asnzs 2918: 2001 3d view frame out - trim out d...

  • Page 9

    17 october 2014 all dimension are in mm………….Copyright © 9 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. General information & operation 1. Double skin the studio stove convection stove – it has an inner and ou...

  • Page 10

    17 october 2014 all dimension are in mm………….Copyright © 10 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. General information & operation 6. Heat output a peak output of approximately 8.9kw can be expected with...

  • Page 11: Studio Door Glass Fitment

    17 october 2014 all dimension are in mm………….Copyright © 11 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. Studio door glass fitment no : 1 no : 2 the studio door glass is a special heat resistance glass designe...

  • Page 12

    17 october 2014 all dimension are in mm………….Copyright © 12 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. No : 5 place the new glass into the door at the bottom. With a 3mm allen key, hook under the air dam and...

  • Page 13

    17 october 2014 all dimension are in mm………….Copyright © 13 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. The studio door and hinge has been designed to give a wide range of adjustment. Studio door adjustment i...

  • Page 14

    17 october 2014 all dimension are in mm………….Copyright © 14 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. Nip up screws while holding door in place, then tighten fully with a 5mm allen key. No : 6 ensure that t...

  • Page 15

    17 october 2014 all dimension are in mm………….Copyright © 15 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. General information & operation information on the paint coating is on the web site: http://www.Forrestp...

  • Page 16

    17 october 2014 all dimension are in mm………….Copyright © 16 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. Model estimated kw peak output kw studio stove 14 8.9 general notes : asnzs 2918 : 2001 notes: for the f...