Warmup WA-XSTAT-V User Manual - page 4
raised. The adaptive function finds out when the
thermostat shall start heating to ensure that the
right temperature is reached at the time that it
has been programmed for.
6.7.4. Offset
Offset is used to compensate for any difference
between the thermostat and a room
thermometer. If the thermometer, for instance,
shows 1°C more than the thermostat, it is
possible to adjust the offset by +/- 5°C. Then
the thermostat will show the same temperature
as the thermometer. If the thermostat for
example shows 1 degree too much, offset
should be set to +1. Then the temperature will
be set 1 degree lower.
Offset applies to both built-in and external
sensors whereas the limit sensor, if any, is not
affected.
6.7.5. Fil Pilote*
Here you can specify temperature settings that
will depend on which signal is received from the
Fil pilote input.
*Please note: The Fil pilote menu is only
available in type WA-XSTAT-VB. It is primarily for
usage in France.
• Eco Temp: Economic temperature
• Frost Prt T: Frost protection
• Fil Pilote: On/Off
6.7.6. Reset
• Reset 2: Reset values defined in Engineer
settings to factory settings.
• Reset 3: Equal to Reset 2, except history
data are deleted. The number of relay
connections is not deleted, though.
7. Error Messages
If you get an error the LED is flashing red.
Internal failure
Contact Warmup
External failure
Contact Warmup
4
Day 1-5
Event
Time
With floor sensor
With air sensor
Day
06:00-08:00
25°C
20°C
Out
08:00-16:00
20°C
15°C
Home
16:00-22:30
27°C
22°C
Night
22:30-06:00
20°C
15°C
Day 6-7
Event
Time
With floor sensor
With air sensor
Day
08:00-23:00
27°C
22°C
Night
23:00-08:00
20°C
15°C
8. Factory settings
The thermostat is delivered with factory set programs as follows:
Tiles
Stone
Laminate
Wood
Carpet
Vinyl
Other
Wire
YES
YES
NO
NO
NO
NO
n/a
Ribbon Wire
YES
YES
YES
YES
NO
NO
n/a
Carbon
YES
YES
YES
YES
YES
YES
n/a
Central heating
n/a
n/a
n/a
n/a
n/a
n/a
n/a
Type A
YES
YES
NO
NO
NO
NO
n/a
Type B
NO
NO
YES
YES
NO
NO
n/a
Type C
NO
NO
NO
NO
YES
YES
n/a
User Defined
n/a
n/a
n/a
n/a
n/a
n/a
n/a
Tiles
Stone
Laminate
Wood
Carpet
Vinyl
Other
Wire
A
A
n/a
n/a
n/a
n/a
H
Ribbon Wire
A
A
B
B
n/a
n/a
H
Carbon
A
A
B
B
C
C
H
Central heating
G
G
G
G
G
G
H
Type A
D
D
n/a
n/a
n/a
n/a
H
Type B
n/a
n/a
E
E
n/a
n/a
H
Type C
n/a
n/a
n/a
n/a
F
F
H
User Defined
H
H
H
H
H
H
H
Configuration
Control temperature
Overheat
Room
Floor
Min. Max.
Min. Max.
Max.
A
5
30
5
40
40
B
5
27
5
27
30
C
5
25
5
25
30
D
5
30
5
50
55
E
5
27
5
45
50
F
5
25
5
35
40
G
5
30
n/a
n/a
H
prog
prog
prog
9. Appendix
9.1. Table of Compatibility
9.2. Heat Definitions
n/a = not available