Water Tech REIONATOR Classic Series Care And Use Manual

Summary of REIONATOR Classic Series

  • Page 1

    Care and use guide reionator ™ classic series with triton electronic control valve wqa gold seal certifi ed to nsf/ansi standards 42 and 44 for meeting or exceeding industry standards of aesthetic chlorine reduction and softening effi ciency. Water tech industries residential reionator™ limited life...

  • Page 2

    Dealer name: dealer phone number installation date: model number: serial number customer checklist after installation, installer should make sure of the following: f customer has a care and use guide and warranty card f customer knows how to restart system if power goes out f customer knows how to p...

  • Page 3

    Maintenance this manual is applicable to one of the following model numbers: rc32-tm, rc40-tm, rc48-tm, rc64-tm, rc80-tm with minimal care, your system is designed to serve you for many years. While con- stant attention to your system is not necessary, the following suggestions will insure your syst...

  • Page 4

    Do’s and do not’s • do always check your state and local regulations regarding plumbing and electrical connections and placement of the system before installation. • do install the reionator™ system into the existing cold water supply line before the water heater and before any cold water outlet tha...

  • Page 5

    Bypass valve operation the bypass valve is typically used to isolate the control valve from the plumbing system’s water pressure in order to perform control valve repairs or maintenance. The 1" full fl ow bypass valve incorporates four positions including a diagnostic position that allows service pe...

  • Page 6

    Plumbing connection raw water in raw water to outside faucets conditioned water in hot cold hot water heater triton bypass valve typical plumbing installation stop check local codes for minimum run between reionator unit and water heater important: brass or plastic yoke assembly (not shown) is requi...

  • Page 7

    Displays & programming instructions general operation: when the reionator ™ is in operation, one of two displays will be shown. The user can alter- nate between the two displays as desired by pressing the ‘next’ button. System operation is not affected by pressing the ‘next’ button. One of the displ...

  • Page 8

    Starting up the system flushing, conditioning and sanitizing did you connect the drain line securely to the valve? Did you connect the brine line securely to the valve? Step 1. Make sure the system is in the “bypass” position before turning the main water back on. See page 12. Make sure the drain li...