Glossary of Terms
Interlock
The interlock feature ensures that the filtration pump is operating prior to allowing another system
component to operate.
Interlink
The interlink feature allows the user to operate two or more functions together. Select the “Interlink”
button and then select the function required to operate with the relevant output.
Integrated Conventional Heater
“Integrated” should be selected for a conventional heater operating within the filtration circuit.
Independent Conventional Heater
“Independent” should be selected for a conventional heater operating separately to the filtration
circuit.
Heater Timer
The “Heater Timer” button allows timer control parameters to be set for the conventional heater.
Heating Demand Option
If “Heating Demand Opt” is selected the conventional heater will continue to operate until the set
temperature is reached overriding any filtration timers.
Set Demand Mode Timer
The “Set Demand Mode Timer” button allows timer control parameters to be set if the “Heating
Demand Opt” is selected.
Integrated Solar
“Integrated” should be selected for a solar system operating within the filtration circuit.
Independent Solar
“Independent” should be selected for a solar system operating separately to the filtration circuit.
Solar Temp Check Period
The Solar Temperature check period for systems with solar heater demand enabled can be adjusted;
otherwise the check delay is set for 2 Hours.
Solar Preference
The “Solar Preference” feature should be selected if the solar heating is to have operational priority
over a conventional heater.
Solar Demand Option
The “Solar Demand Opt” feature should be selected if the solar heating is to continue to operate
while there is solar gain overriding any filtration timers.
Select Solar Output
The “Select Solar Output” feature allows water control selection to the solar system via either a
Solar Pump or Solar Valve.
Freeze Protection
Freeze protection is used to protect the pool hydraulics and plumbed equipment against freeze
damage. If freeze protection is enabled and the AIR temperature falls below 3oC, Aquamaster will
turn on the filter pump to circulate the water. If in “Pool and Spa” mode the valves will also alternate
between the pool and spa every 30 minutes.