Waterford EMERALD E65-LP1 Owners & Installation Manual

Summary of EMERALD E65-LP1

  • Page 1

    Fpi fireplace products international ltd. 6988 venture st., delta, bc canada, v4g 1h4 warning: if the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. For your safety do not store or use gasoline or o...

  • Page 2: Waterford

    2 waterford e65-1 emerald direct vent freestanding gas stove waterford emerald direct vent freestanding gas stove to the new owner: congratulations! You are the owner of a state-of-the-art waterford direct vent freestanding gas stove by waterford irish stoves. The waterford gas series of hand crafte...

  • Page 3: Table of Contents

    Waterford e65-1 emerald direct vent freestanding gas stove 3 table of contents page page support extension - round or square ....................... 22 converting a class-a metal chimney or masonry chimney to a direct vent system ...................... 22 system data chart .............................

  • Page 4: Safety Label

    4 waterford e65-1 emerald direct vent freestanding gas stove this is a copy of the label that accompanies each emerald direct vent freestanding gas stove. We have printed a copy of the contents safety label here for your review. The safety label is located on the inside of the drop down pedestal doo...

  • Page 5: Safety Label

    Waterford e65-1 emerald direct vent freestanding gas stove 5 safety label copy of safety label for e65-lp1 propane stove for the state of massachusetts, installation and repair must be done by a plumber or gasfitter licensed in the commonwealth of massachusetts. For the state of massachusetts, flexi...

  • Page 6: Important:

    6 waterford e65-1 emerald direct vent freestanding gas stove important: save these instructions the emerald direct vent freestanding gas stove must be installed in accordance with these instructions. Carefully read all the in- structions in this manual first. Consult the build- ing authority having ...

  • Page 7: Installation

    Waterford e65-1 emerald direct vent freestanding gas stove 7 installation pages 11 and 12 for the required vent arrangements. If installed into a manufac- tured home the unit must be bolted down to the floor. 4) this appliance is listed for bedroom instal- lations when used with a listed millivolt t...

  • Page 8: Optional Fan Installation

    8 waterford e65-1 emerald direct vent freestanding gas stove optional fan installation diagram 1 diagram 2 installation locating your emerald gas stove when selecting a location for your stove, en- sure that the clearances listed above are met as well as ensuring that there is adequate acces- sibili...

  • Page 9: Installation

    Waterford e65-1 emerald direct vent freestanding gas stove 9 installation precautions these venting systems are engineered prod- ucts that have been designed and tested for use with the e65-ng1, and e65-lp1. The war- ranty will be voided and serious fire, health or other safety hazards may result fr...

  • Page 10: Installation

    10 waterford e65-1 emerald direct vent freestanding gas stove installation exterior vent terminal locations a= clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm) b= clearance to window or door that may be opened *(12"/30cm) #(9"/23cm) c= clearance to permanently closed window *...

  • Page 11: Installation

    Waterford e65-1 emerald direct vent freestanding gas stove 11 installation rigid pipe venting components list all simpson dura-vent components are available directly from fpi. Description simpson dura-vent selkirk amerivent r direct ventgs r direct-temp tm direct vent 6" pipe length, galvanized 908 ...

  • Page 12: Installation

    12 waterford e65-1 emerald direct vent freestanding gas stove horizontal venting rigid pipe venting - horizontal terminations the shaded area in the diagram below shows all allowable combinations of vertical runs with horizontal terminations. Maximum one 90 o elbow (two 45 o elbows equal one 90 o el...

  • Page 13: Installation

    Waterford e65-1 emerald direct vent freestanding gas stove 13 installation rigid pipe venting - vertical terminations for both residential & manufactured homes/mobile homes the shaded areas in the two diagrams below show all allowable combinations of straight vertical and offset to vertical runs wit...

  • Page 14: Installation

    14 waterford e65-1 emerald direct vent freestanding gas stove vertical termination with co-linear flex system this appliance is designed to be attached to two 3" (76mm) co-linear aluminium flex running the full length of the chimney. See the venting arrangements chart below for minimum and maximum f...

  • Page 15: Installation

    Waterford e65-1 emerald direct vent freestanding gas stove 15 installation dv stove horizontal vent kit dv 2 ft. Stove vent kit (part # 946-116) and dv 4 ft. Stove vent kit (946-216) includes all the parts needed to install the e65 direct vent unit with minimum horizontal and vertical vent dimension...

  • Page 16: Installation

    16 waterford e65-1 emerald direct vent freestanding gas stove dv stove horizontal vent kit (# 946-116 & #946-216) installation review the following sequence of instructions which are typical of most installations. The sequence may vary depending on wall thick- ness. Refer to pages 10 to 14 for vent ...

  • Page 17: Installation

    Waterford e65-1 emerald direct vent freestanding gas stove 17 installation dura-vent termination kit planning your dura-vent installation there are two basic types of dura-vent direct vent system installations: horizontal termina- tion and vertical termination. Confirm the maxi- mum horizontal run a...

  • Page 18: Installation

    18 waterford e65-1 emerald direct vent freestanding gas stove you will require the following components with your new emerald direct vent freestanding gas stove. Please review your product to make sure you have everything you need. In the event that you are missing any part, contact your dealer. Not...

  • Page 19: Installation

    Waterford e65-1 emerald direct vent freestanding gas stove 19 note: a) the horizontal run of vent should have a 1/4 inch rise for every 1 foot of run towards the termination. Never allow the vent to run downward. This could cause high temperatures and may present the possibility of a fire. B) the lo...

  • Page 20: Dura-Vent Vertical

    20 waterford e65-1 emerald direct vent freestanding gas stove diagram 9 dura-vent vertical termination diagram 7 diagram 8 3) to install the round support box/wall thim- ble in a flat ceiling, cut a 10 inch square hole in the ceiling centred on the hole drilled in step 2. Frame the hole as shown in ...

  • Page 21: Cathedral Ceilings

    Waterford e65-1 emerald direct vent freestanding gas stove 21 cathedral ceilings round support (rds) & square support (sqs) if your home has a cathedral ceiling (no attic space between the ceiling and the roof), install the chimney and support as follows. 1) situate the chimney in a convenient loca-...

  • Page 22: Installation

    22 waterford e65-1 emerald direct vent freestanding gas stove installation diagram 3 diagram 4 diagram 5 4) pass the flex pipe down through the center of the chimney system, and center the adaptor on the top of the chimney pipe. Drill four 1/8" diameter holes through the adap- tor and into the chimn...

  • Page 23: Installation

    Waterford e65-1 emerald direct vent freestanding gas stove 23 converting a masonry chimney important: the existing masonry flue opening needs to have an area of at least a 36 sq. In. To insure proper intake/ex- haust flow. 1) before cutting any holes, assemble the desired sections of black direct ve...

  • Page 24: Aeration

    24 waterford e65-1 emerald direct vent freestanding gas stove aeration adjustment the burner aeration is factory set but may need adjusting due to either the local gas supply, air supply or altitude. High elevation this unit (with 38,000 btu) is approved in can- ada for altitude 2000 ft. To 4500 ft....

  • Page 25: Conversion Kit

    Waterford e65-1 emerald direct vent freestanding gas stove 25 4) carefully remove the logs, embers and rockwool. 5) remove burner. See diagram below. Pilot assembly is now accessible for steps 6) to 11). Note: use a magnetic type screwdriver if possible. This conversion must be done by a qualified g...

  • Page 26: Reduction Kit to

    26 waterford e65-1 emerald direct vent freestanding gas stove reduction kit to lower btu rating for e65-1 gas stove 3) open the front door. Open the right side door and there is a cutout in the heat shield through which can be seen a wing nut threaded on to a stud attached to the front door. Loosen ...

  • Page 27: Optional Door

    Waterford e65-1 emerald direct vent freestanding gas stove 27 optional door grill installation door grill kit contains: qty. Description 1 front door grill 4 screws 4 grill clips 1) open the front door. Open the right side door and there is a cutout in the heat shield through which can be seen a win...

  • Page 28: Optional Wall

    28 waterford e65-1 emerald direct vent freestanding gas stove optional wall thermostat a wall thermostat may be installed if desired. Connect the wires as per the wiring diagrams. Note that the wires are connected to the "th" on the gas valve. Use table below to determine the maximum wire length: no...

  • Page 29: Operating

    Waterford e65-1 emerald direct vent freestanding gas stove 29 operating instructions 1) read and understand these instructions before operating this appliance. 2) check to see that all wiring is correct and enclosed to prevent possible shock. 3) check to ensure there are no gas leaks. 4) make sure t...

  • Page 30: Operating Instructions

    30 waterford e65-1 emerald direct vent freestanding gas stove copy of the lighting plate instructions operating instructions pilot does not remain lit, repeat operation allowing a longer period before releasing gas control knob. 4) when the pilot stays lit, turn the gas knob further counterclockwise...

  • Page 31: Maintenance

    Waterford e65-1 emerald direct vent freestanding gas stove 31 8) each time the appliance is lit, it may cause condensation and fog the glass. This con- densation and fog is normal and will disap- pear in a few minutes as the glass heats up. Never operate the appliance without the glass properly secu...

  • Page 32: Fan Maintenance

    32 waterford e65-1 emerald direct vent freestanding gas stove fan maintenance if your fan requires maintenance or replace- ment, access to the fan is through the rear access panel on the back of the unit. Note: the unit must not be operated without the fan access panel securely in place and correctl...

  • Page 33: Removing Valve

    Waterford e65-1 emerald direct vent freestanding gas stove 33 11) carefully lift the burner tray assembly out. Removing valve if your valve requires maintenance or replace- ment, use the following instructions: note: always close off the gas supply before removing the valve. 1) if optional fan is in...

  • Page 34: Parts List

    34 waterford e65-1 emerald direct vent freestanding gas stove parts list main assembly 1) w400141** emerald right door (black) 2) 904-258 door magnet 3) 948-134 door stop 4) 44351 black butt hinge 5) w842001** emerald right side (black) 6) 41211 tape gasket w/adhesive backing 7) * heat shield - righ...

  • Page 35: Burner & Log Assembly

    Waterford e65-1 emerald direct vent freestanding gas stove 35 burner & log assembly 52) 910-190 piezo ignitor & nut 56) 908-672 control panel decal 57) 490-061 switch plate 910-896 high temperature wire harness - to power cord 261-574/p valve assembly s.I.T. - natural gas 261-576/p valve assemlby s....

  • Page 36: Notes

    36 waterford e65-1 emerald direct vent freestanding gas stove _____________________________________________________________________________________ ____________________________________________________________ __________________________________________________________ ________________________________...

  • Page 37: Notes

    Waterford e65-1 emerald direct vent freestanding gas stove 37 _____________________________________________________________________________________ ____________________________________________________________ __________________________________________________________ ________________________________...

  • Page 38: Notes

    _____________________________________________________________________________________ ____________________________________________________________ __________________________________________________________ ____________________________________________________________ _________________________________...

  • Page 39: Warranty

    Warranty waterford fireplace products are designed with reliability and simplicity in mind. In addition, our internal quality assurance team carefully inspects each unit thoroughly before it leaves our facility. Fpi fireplace products international ltd. Is pleased to extend this limited lifetime war...

  • Page 40: Before It Leaves Our Door.

    Installer: please complete the following information dealer name & address: ________________________________________________ ______________________________________________________________________ installer: ______________________________________________________________ phone #: _____________________...