Waterford JSAL15D Owner's Manual

Other manuals for JSAL15D: Installation, Operation & Parts

Summary of JSAL15D

  • Page 1

    Waterford systems high rate sand filter system for above ground swimming pools o w n e r ’ s m a n u a l installation, operation & parts sta-rite pool/spa group 293 wright street, delavan, wi 53115 international: 262-728-5551, fax: 262-728-7550 www.Starite.Com union city, tn • delavan, wi • mississa...

  • Page 2: Save These Instructions

    2 high-rate sand filter system to avoid unneeded service calls, prevent possible injuries, and get the most out of your filter, read this manual carefully! The high rate sand filter system: • is designed to circulate and filter water in above ground swimming pools. • offers quiet, efficient performa...

  • Page 3

    3 this is the safety-alert symbol. When you see this symbol on your valve or in this manual, look for one of the following signal words and be alert to the potential for personal injury. Warns about hazards that will cause se- rious personal injury, death or major property damage if ignored. Warns a...

  • Page 4

    1-1/2" npt return to pool (union connection) 1-1/2" npt suction connection 1-1/2" npt waste outlet (union connection) 23 2-13/16 a b 7 11 1278 0994 drain (to tank flange) d 2-5/16 9-1/16 11-1/4 tank dia. C e 1279 0994 4 table i - outline dimensions in inches (mm) filter model a b c d e 15”(406mm) fi...

  • Page 5

    5 general information • clean a new pool as well as possible before filling pool and operating filter. Excess dirt and large particles of foreign matter in the system can cause serious dam- age to the filter and pump. Never test this filter with compressed air. Do not operate filter at water tempera...

  • Page 6

    6 filter setup assembly: see figures 2 through 5 for filter assembly. Loading sand media 1. To keep sand out of collector assembly, place plastic sand shield over top of collector tube before pouring sand into filter (see figure 5). 2. To support laterals and prevent lateral breakage dur- ing loadin...

  • Page 7

    7 8. System is ready for startup. Notice: if there are leaks from beneath valve/clamp area, stop pump, release all pressure, remove clamp and valve and clean sealing surfaces. Follow directions under “valve installation”, page 6, when reinstalling valve. See figures 6 and 7. Electrical risk of elect...

  • Page 8

    8 table iii–recommended fusing data, 115 volt 60 hz motors. Branch pump motor full load circuit breaker model no. H.P. Amps rating (amps) jwpa5dc-2a3 3/4 9.4 15 jwpa5ec-2a3 1 11.9 15 jwps5fc-2a3 1-1/2spl 11.9 15 17290-j1002 (2-speed) 1 – 1/6 11.6/3.3 15 notice: values given are for pump motor only. ...

  • Page 9

    9 hazardous pressure. To avoid explosion and possible severe or fatal injury, filter system pressure must not exceed 50 psi (345 kpa) under any circum- stances. Never test this filter system with compressed air; never operate system with water temperature above 95° f (35° c). To prevent equipment da...

  • Page 10

    10 storage/ winterizing pool chemicals may give off corrosive fumes. Store chemicals away from system in a well ven- tilated area. Notice: allowing water to freeze will damage filter and void warranty. If antifreeze is needed, use propylene glycol; it’s plastic compatible and non-toxic. Follow manuf...

  • Page 11

    11 multi-port valve service hazardous pressure. Stop pump and re- lease all pressure from system before working on filter, valve, or clamp. Notice: if multi-port valve is below pool water level, close suction and discharge valves before disassembly to prevent draining pool. Handle replacement: 1. St...

  • Page 12

    12 to avoid dangerous or fatal electrical shock haz- ard, turn off power to motor before working on pump or motor. Trap needs no lubrication or regular maintenance be- yond reasonable care and periodic cleaning of strainer basket. If shaft seal is worn or damaged, repair as follows: pump disassembly...

  • Page 13

    13 troubleshooting guide – pump read and understand safety and operating instruc- tions in this manual before doing any work on pump. A. Pump does not operate: 1. Check gfci (ground fault circuit interrupter) for proper operation according to gfci manufac- turer’s instructions. 2. Check for blown fu...

  • Page 14

    14 models jsal180d jsal210d jsal180e jsal210e jsal15d jsal180e jsal210e jsal15e jsals180e jsal210f key no. Jsals15e jsal180f jsals210f no. Part description used 15” filter 18” filter 21” filter 1 pump* (models with -06, -09 suffix) 1 jwp series jwp series jwp series 1 pump** (all other suffixes) 1 j...

  • Page 15

    15 • not illustrated. * not available separately. Model motor no. Impeller no. No. Hp (key no. 6) (key no. 11) single speed jwpa5dc-2a3 3/4 as901dl c105-228pwbs jwpa5ec-2a3 1 as901el c105-228pws jwps5fc-2a3 1-1/2spl as901sfl c105-228pws dual speed 17290-j1002 1 – 1/6 17182-0090 c105-228pws model cor...

  • Page 16: Jwpa Pumps

    16 6 8 9 10 11 12 13a 13 14 19 21 22 23 13b 15 17 16 18 19 20 381 1293 model number key no. Description qty. 3/4 hp 1 hp 1- 1/2 hp 6 motor 115/60h/1ph (without cord) 1 as920dll as920ell as920fll 6 motor 230/60h/1ph (without cord) 1 – as923el – 6 motor 115/60h/1ph 1-speed (without cord) 1 – – 62003-2...

  • Page 17: Abg Pumps

    17 abg pumps • not illustrated. * included with top discharge pumps only. 8 9 1 2 6 7 4 3 10 11 12 5 do not ove rti ght en 13 14 15 3345 1198 key part part no. Description qty. No. 1 motor 1 chart at right 2 slinger 1 c69-2 3 seal plate 1 17500-0001 4 seal plate o-ring 1 35505-1438 5 shaft seal 1 u1...

  • Page 18

    18 re cir c u la te b a c k w a s h c l o se d w i nteriz e w a s t e f il te r rin se 1 2 3 4 5 6 7 8 9a 10 11 9b 12 13 14 15 16 aquatools .Waterford, wi. 53185 usa 762 0294 key part no. Description qty. Number 1 decal, valve handle 1 32145-4016 2 handle 1 14962-0032 3 dowel pin 1 35857-0021 4 wash...

  • Page 19

    19.

  • Page 20

    Create a record of your warranty at sta-rite: • complete a warranty registration at www.Staritepool.Com by clicking on “register products” and selecting sta-rite pool or • complete bottom portion completely and mail within 10 days of installation to sta-rite, attn.: pool warranty dept., 293 wright s...

  • Page 21

    20

  • Page 22

    En re gis tr ez vo tr ec er tif ic at de ga ra nt ie ch ez st a-r it e: •r em plis se zle fo rm ula ire d’e nre gis tre me nt de ga ra ntie dis po nib le su rle site ww w.S ta rite po ol.C om en cliq ua nt su r« re gis te rp ro du cts », pu is su rs ta -r ite po ol ou •r em plis se zle co up on ci- ...

  • Page 23

    18 ré f. De sig na tio nd ep ié ce s qté n° de sp iè ce s 1 dé ca lc om an ie – po ig né e de la va nn e 1 32 14 5-4 01 6 2 po ig né e 1 14 96 2-0 03 2 3 go up ill ed 'im mo bil isa tio n 1 35 85 7-0 02 1 4 ro nd ell e 1 14 96 5-0 00 7 5 dé ca lc om an ie –i nst ru cti on s de fo nc tio nn em en t 1...

  • Page 24

    Po mp es ab g •p iè ce sn on ill us tré es . *l iv ré ea ve cl es po mp es àr efo ule me nt en ha ut se ule me nt. 8 9 1 2 6 7 4 3 10 11 12 5 do no t ov er tig ht en 13 14 15 3345 1198 n° de s ré f. De sig na tio nd ep ié ce s qté piè ce s 1 mo te ur 1 ta ble au ci- co ntr e 2 dé fle cte ur 1 c6 9-2...

  • Page 25

    16 6 8 9 10 11 12 13a 13 14 19 21 22 23 13b 15 17 16 18 19 20 381 1293 nu mé ro du mo dè le jw pa 5d l-2 a1 jw pa 5e l-2 a1 jw pa 5f l-2 a1 jw pa 5d l-2 a2 jw pa 5e l-2 a2 jw pa 5f l-2 a2 jw pa 5e -2 30 a2 jw pa s5 f-2 a4 u jw pa 5y el -a 2u jw pa 5y fl -a 2u ré f. Dé sig na tio n qté 3/4 ch 1c h 1-...

  • Page 26

    15 •p iè ce sn on ill ust ré es. *p as dis po nib le sé pa ré me nt. 1 2 3 4 5 6 7 8 9 10 13 13b 13a 12 11 14 20 21 22 23 19 24 25 26 9a 15 16 17 18 19 notice: at23 series models use the same front plate and seal plate as other models; however, they are rotated 90 ° counter-clockwise when installed....

  • Page 27

    14 •pièces non illustrées. *voirpage 15 . **voir page1 6. ** *l et uy au so up le de 2m (6 pi) n’e st pa sl iv ré av ec le sm od èle sj sa l1 5d -5 9, js al 18 0f -0 5e tj sa l2 10 f-0 5. 7 8 17 16 15 14 13 12 11 10 9 1 3 2 18 19 4a 4b 5 6 1277 0994 lis te de sp iè ce sd er ec ha ng e- fil tre mo dÈ...

  • Page 28

    13 gu id ed ed ia gn os - ti cd es p a nn es de la po mp e avant de procéder à toute intervention sur cette pompe, bien lire et bien comprendre toutes les consignes de sécurité et toutes les instructions de fonctionnement! A. La pompe ne fonctionne pas : 1. S'assurer que le disjoncteur de circuit en...

  • Page 29

    12 pour éviter tout risque de secousses électriques dan- gereuses ou mortelles, interrompre l'arrivée de courant parvenant au moteur avant d'intervenir sur la pompe ou sur le moteur! Aucune lubrification ni aucun entretien périodique de la cuve ne sont requis, si ce n'est un entretien normal et un n...

  • Page 30

    1 1 en tr et ie nd es va nn es Ào rif ic es mu l t ip le s pression dangereuse. Arrêter l a pompe et dissiper toute la pression du système avant d'intervenir sur le filtre, la vanne ou le collier. Nota : sila vanne à orifices multiples est plus basse que le niveau de l'eau de la piscine, fermer les ...

  • Page 31

    10 en tr ep os ag ee t pr Ép ar a t io np ou r l'h iv er lesproduits chimi ques utilisés dans les piscines dégagent des vapeurs corrosives. Les entreposer loin du sys- tème dans un endroit bien aéré. Nota : sile filtre gèle, il sera endommagé et la garantie sera annulée. Si l'on utilise de l'antigel...

  • Page 32

    9 pression dangereuse. Pour éviter une explo- sion et des blessures graves possibles, voire mortelles, la pres- sion du système de filtration ne doit jamais dépasser 345 kpa (50 l b/pi 2 ). Ne jamais contrôler ce système de filtration à l'air comprimé; ne jamais faire fonctionner le système si la te...

  • Page 33

    8 t ableau iii - protection r ecommandée pour les moteurs fonctionnant sur le 115 v olts,60 hz. Ca pa cit éd u dis jo nc te ur de n° de pu iss an ce du am pè re sà la dé riv ati on po mp es mo te ur en ch ple in ec ha rg e (e na mp ère s) jw pa 5d c-2 a3 3/4 9,4 15 jw pa 5e c-2 a3 1 11 ,9 15 jw ps 5...

  • Page 34

    7 a. Le tuyau de l'orifice retour (return) de la vanne doit être orienté vers le retour de la piscine. B. Le tu ya uv en an td el 'o rif ic ee au us Ée (w as te )d el av an ne do it êtr eo rie nté ve rs le cô té où l'e au usé es era en vo yé e. C. Le tuyau d’aspiration provenant de la pompe doit êtr...

  • Page 35

    6 mo nta ge du fil tre assemblage : voir les figures 2 à 5 pour l'assemblage du filtre. Ch ar ge me nt du sa ble da ns le fil tre 1.Ne pas verser de sable dans la conduite centrale; poser le protecteur de sable en plastique sur la conduite centrale avant de verser le sable dans le filtre (voir la fi...

  • Page 36

    5 re ns ei gn em en ts gÉ nÉ ra ux •si la piscine est neuve, la nettoyer le mieux possible avant de la remplir et de faire fonctionner le filtre. Le filtre et la pompe risquent d'être sérieusement endommagés si le sys- tème contient trop de saletés ou de grosses particules de corps étrangers. Ne jam...

  • Page 37

    1-1/2" npt return to pool (union connection) 1-1/2" npt suction connection 1-1/2" npt waste outlet (union connection) 23 2-13/16 a b 7 11 1278 0994 drain (to tank flange) d 2-5/16 9-1/16 11-1/4 tank dia. C e 1279 0994 4 ta bl ea ui -d im en sio ns ex tÉ rie ur es en po uc es (m m) mo dè le de fil tr...

  • Page 38

    3 ce symbole indique qu'il faut être prudent. Lorsque ce symbole apparaît sur la vanne ou dans cette notice, rechercher un des dangers, avertissements ou atten- tions qui suivent, car ils indiquent la possibilité de blessures corporelles. Avertit d'un danger qui causera desblessures corporelles, la ...

  • Page 39: Sé

    2 sy st Èm ed ef il tr a t io nÀ sa bl eÀ gr an dd Éb it pour éviter les appels inutiles d'un réparateur, éviter toutes blessures possibles et obtenir le meilleur rendement de ce système de filtration, lire attentivement cette notice! Lesystème de filtration à sable à grand débit aquatools : • est c...

  • Page 40: Stè

    Sy stè me wa te rfo rd sy stè me de fil tra tio nà sa ble àg ra nd dé bit po ur pis cin es ho rs- so l n o t i c e d ’ u t i l i s at i o n po se ,f on ct io nn em en te tp iÈ ce s ce tte no tic ed oit êtr er em ise àl 'u til isa te ur de ce sy stè me de fil tra - tio n; ell es erv ira àr éd uir el ...