Waterford TARA T25-LP Owners & Installation Manual

Summary of TARA T25-LP

  • Page 1

    Fpi fireplace products international ltd. 6988 venture st., delta, bc canada, v4g 1h4 warning: if the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. For your safety do not store or use gasoline or o...

  • Page 2: Waterford

    2 waterford tara t25 direct vent freestanding gas stove waterford tara direct vent freestanding gas stove to the new owner: congratulations! You are the owner of a state-of-the-art waterford direct vent freestanding gas stove by waterford irish stoves. The waterford gas series of hand crafted applia...

  • Page 3: Table of Contents

    Waterford tara t25 direct vent freestanding gas stove 3 table of contents converting a factory built metal chimney .............. 22 high elevation ...................................................... 23 system data chart .............................................. 24 gas connection ..............

  • Page 4: Safety Label

    4 waterford tara t25 direct vent freestanding gas stove this is a copy of the label that accompanies each tara direct vent freestanding gas stove. We have printed a copy of the contents safety label here for your review. The safety label is located on the inside of the drop down pedestal door. Copy ...

  • Page 5: Important:

    Waterford tara t25 direct vent freestanding gas stove 5 important: save these instructions the tara direct vent freestanding gas stove must be installed in accordance with these instructions. Carefully read all the instructions in this manual first. Consult the building author- ity having jurisdicti...

  • Page 6: Installation

    6 waterford tara t25 direct vent freestanding gas stove specified vent and termination cap to the outside of the building envelope. Never vent to another room or inside a building. Make sure that the vent is fitted as per the instruc- tions starting on page 9. 6) inspect the venting system annually ...

  • Page 7: Optional Fan

    Waterford tara t25 direct vent freestanding gas stove 7 optional fan installation for units starting with serial # 11106 to 13347 / 217000001 to present. Fan kit contains: qty. Description 1 fan assembly c/w green wire attached 1 thermodisc 1 power cord 2 2-1/4" x 20 hex nut 1) remove the thermodisc...

  • Page 8: Installation

    8 waterford tara t25 direct vent freestanding gas stove installation 9) connect the red wire from the thermodisc to the red wire of the speed control wire harness. 10) connect the live black wire from power cord to the black wire of the speed control wire harness. 12) ensure all wires are pulled awa...

  • Page 9: Venting

    Waterford tara t25 direct vent freestanding gas stove 9 venting introduction the following vent systems in combination with the tara direct vent freestanding gas stove, have been tested and listed as direct vent heater systems by warnock hersey: 1) the minimum horizontal termination with the dv stov...

  • Page 10: Installation

    10 waterford tara t25 direct vent freestanding gas stove installation exterior vent terminal locations a= clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm) b= clearance to window or door that may be opened *(12"/30cm) #(9"/23cm) c= clearance to permanently closed window *(min....

  • Page 11: Installation

    Waterford tara t25 direct vent freestanding gas stove 11 installation residential and manufactured homes / mobile homes miniumum horizontal termination installations you will require the following components with your new regency rear vent direct vent freestanding gas stove. Please review your produ...

  • Page 12: Horizontal

    12 waterford tara t25 direct vent freestanding gas stove diagram 4 diagram 2a diagram 3 horizontal installations 1) set the unit in its desired location. Check to determine if wall studs are in the way when the venting system is attached. If this is the case, you may want to adjust the location of t...

  • Page 13: Installation

    Waterford tara t25 direct vent freestanding gas stove 13 installation vertical termination with co-linear flex system this appliance is designed to be attached to two 3" (76mm) co-linear aluminium flex running the full length of the chimney. The flue length must be a minimum length of 8 ' (2.44m) an...

  • Page 14: Installation

    14 waterford tara t25 direct vent freestanding gas stove dv stove horizontal vent kit (#946-116 & #946-216) installation review the following sequence of instructions which are typical of most installations. The sequence may vary depending on wall thick- ness. Refer to pages 11 to 18 for vent locati...

  • Page 15: Dura-Vent

    Waterford tara t25 direct vent freestanding gas stove 15 dura-vent termination kit planning your dura-vent installation there are two basic types of dura-vent direct vent system installations: horizontal termina- tion and vertical termination. Confirm the max- imum horizontal run and maximum vertica...

  • Page 16: Installation

    16 waterford tara t25 direct vent freestanding gas stove installation from the rear of the unit to the wall. It is also important to note the wall thickness. (the wall thimble is suitable for 2 x 4 or 2 x 6 wall construction.) select the amount of vertical rise desired for "vertical-to-horizontal" t...

  • Page 17: Installation

    Waterford tara t25 direct vent freestanding gas stove 17 installation rigid pipe venting components list all simpson dura-vent components are available directly from fpi. Description simpson dura-vent selkirk amerivent r direct ventgs r direct-temp tm direct vent 6" pipe length, galvanized 908 4dt-6...

  • Page 18: Installation

    18 waterford tara t25 direct vent freestanding gas stove installation rigid pipe venting - vertical terminations for both residential & manufactured homes/mobile homes the shaded areas in the two diagrams below show all allowable combinations of straight vertical and offset to vertical runs with ver...

  • Page 19: Dura-Vent

    Waterford tara t25 direct vent freestanding gas stove 19 b) horizontal runs of vent must be sup- ported every three feet. Wall straps are available for this purpose. 3) with the pipe attached to the stove, slide the stove into its correct location, and mark the wall for a 10" x 10" (inside dimension...

  • Page 20: Installation

    20 waterford tara t25 direct vent freestanding gas stove diagram 9 diagram 8: the upper half of the flashing is installed under the roofing material and not nailed down until the chimney is installed. This allows for small adjustments. Installation diagram 7 diagram 5 diagram 6 5) cut a hole in the ...

  • Page 21: Cathedral Ceilings

    Waterford tara t25 direct vent freestanding gas stove 21 cathedral ceilings round support (rds) & square support (sqs) if your home has a cathedral ceiling (no attic space between the ceiling and the roof), install the chimney and support as follows. 1) situate the chimney in a convenient location a...

  • Page 22: Installation

    22 waterford tara t25 direct vent freestanding gas stove converting a masonry chimney important: the existing masonry flue opening needs to have an area of at least a 36 sq. In. To insure proper intake/ex- haust flow. 1) before cutting any holes, assemble the desired sections of black direct vent pi...

  • Page 23: Installation

    Waterford tara t25 direct vent freestanding gas stove 23 diagram 7 4) to determine the length of flex required, measure from 3" (76mm) above the top of the flashing down to the level of the open- ing. Add to this measurement the distance from the center of the chimney to out through the wall. Cut a ...

  • Page 24: Conversion Kit

    24 waterford tara t25 direct vent freestanding gas stove conversion kit from natural gas to propane kit: #290-969 for tara gas stove using sit 820 nova gas valve conversion kit contains: 1 910-018 sit conversion kit-50% turndown lp 1 910-037 sit lp pilot orifice 1 904-345 rear burner orifice #53 1 9...

  • Page 25: Installation

    Waterford tara t25 direct vent freestanding gas stove 25 8) unscrew the pilot orifice with the allen key and replace with the lp pilot orifice in the kit. Installation 1) shut off the gas supply. 2) remove the cast iron front panel. Hold the cast iron front panel at the bottom and lift upwards and o...

  • Page 26: Optional

    26 waterford tara t25 direct vent freestanding gas stove optional front grill 1) remove the cast iron front panel. Catch the cast iron front panel at the bottom and lift upwards and out from the stove. Once free of the locating tabs, the panel can be dropped down; freeing it from the top of the stov...

  • Page 27: Optional Wall

    Waterford tara t25 direct vent freestanding gas stove 27 optional wall thermostat a wall thermostat may be installed if desired. Connect the wires as per the wiring diagrams. Note that the wires are connected to the "th" on the gas valve. Use table on page 27 to determine the maximum wire length: no...

  • Page 28: Wiring Diagram - Tara

    28 waterford tara t25 direct vent freestanding gas stove wiring diagram - tara this heater does not require a 120v a.C. Supply for operation. In case of a power failure, the burner switch and the optional remote control/thermostat will continue to operate. However, a 120v a.C. Power supply is needed...

  • Page 29: Operating Instructions

    Waterford tara t25 direct vent freestanding gas stove 29 operating instructions operating instructions 1) read and understand these instructions before operating this appliance. 2) check to see that all wiring is correct and enclosed to prevent possible shock. 3) check to ensure there are no gas lea...

  • Page 30: Normal Operating

    30 waterford tara t25 direct vent freestanding gas stove normal operating sounds of gas appliances it is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance. Listed below...

  • Page 31: Maintenance

    Waterford tara t25 direct vent freestanding gas stove 31 maintenance top view of pilot flame maintenance instructions 1) always turn off the valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a ...

  • Page 32: Maintenance

    32 waterford tara t25 direct vent freestanding gas stove valve bracket with valve - top view screw screw screw screw stove front maintenance valve maintenance if your valve requires maintenance or replace- ment, use the following instructions. Note: always close off the gas supply before removing th...

  • Page 33: Parts List

    Waterford tara t25 direct vent freestanding gas stove 33 replacement / spare parts list parts list 1) w260021** front casting (black) 2) 280-022 door 3) w260040/p glass 4) 41225 gasket for glass 6) 904-012 capscrew 1/4 x 1-3/4 nc 8) 260350 gasket for rear relief plate 9) 290-015 rear blow off plate ...

  • Page 34: Notes

    _____________________________________________________________________________________ ____________________________________________________________ __________________________________________________________ ____________________________________________________________ _________________________________...

  • Page 35: Warranty

    Warranty waterford fireplace products are designed with reliability and simplicity in mind. In addition, our internal quality assurance team carefully inspects each unit thoroughly before it leaves our facility. Fpi fireplace products international ltd. Is pleased to extend this limited lifetime war...

  • Page 36: Before It Leaves Our Door.

    Installer: please complete the following information dealer name & address: ________________________________________________ ______________________________________________________________________ installer: ______________________________________________________________ phone #: _____________________...