WaterGroup 15201 SERIES Installation manual & owner's manual

Manual is about: AquaSafe WATER TREATMENT SYSTEMS/15201 SERIES REVERSE OSMOSIS/ 15203 SERIES MECHANICAL FILTRATION/ 15202 SERIES ULTRAVIOLET LIGHT WITH MECHANICAL FILTRATION

Summary of 15201 SERIES

  • Page 1

    Installation manual & owner’s guide water treatment systems 15201 series reverse osmosis 15203 series mechanical filtration 15202 series ultraviolet light with mechanical filtration.

  • Page 2

    Introduction i system description the aquasafe™ expandable modular water treatment system consists of patented individual, self-contained, ready-to-install module assemblies. The module assemblies may be installed as stand-alone units or interconnected to form a complete, multi-phase system. A modul...

  • Page 3

    Introduction ii basic system configurations reverse osmosis systems modules filter module types rinse water flow model number output (gpd) qty type sediment carbon membrane 25% recovery 50% recovery 15201201 125 2 #13 5 micron thin film composite 375 gpd 125 gpd 15201202 125 2 #13 10 micron thin fil...

  • Page 4

    Introduction iii operation and maintenance requirements conditions for system use, all media types table 1 system type process media thin film composite membrane sediment/activated carbon ultraviolet output specification 125 gpd 250 gpd all all source water supply profile community/private chlorinat...

  • Page 5

    Introduction 1 installation requirements caution: follow the directions in this guide when installing your system to ensure that it operates correctly. Caution: the aquasafe water treatment systems are designed for indoor use only. Location 1. A module may be mounted on any vertical surface capable ...

  • Page 6

    Mechanical filtration and reverse osmosis modules installation and connection procedures 2 the system must be installed in accordance with applicable city, state, and local plumbing codes. Aquasafe™ is designed to provide years of trouble-free service if properly maintained. Retain these instruction...

  • Page 7

    Mechanical filtration and reverse osmosis modules installation and connection procedures 3 5. Caution: hold the membrane firmly to prevent it from rotating when the elbow is installed caution: when tightened, rotate the membrane so that the elbow is pointed toward the drain connection (see figure 1)...

  • Page 8

    Mechanical filtration and reverse osmosis modules installation and connection procedures 4 item description part no. Item description part no. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 valve, solenoid nipple, 3/4” connector, inlet/outlet 1/2” fpt connector, inlet/outlet 3/4” fpt “o” ring, connect...

  • Page 9

    Reverse osmosis module support component installation procedure 5 electronic control box warning: do not use an extension cord to run electrical power to the system. Warning: electrical connections must comply with all local codes. An electronic control box (item 24) connected to the solenoid valve ...

  • Page 10

    Reverse osmosis module support component installation procedure 6 caution: the p/t lockout and tank level shut-off connections require dry contacts. The terminal strip accepts dry contact switch signals capable of handling 50 ma at 24vac. Pretreatment lockout device (p/t) p/t device is not installed...

  • Page 11

    Mechanical filtration or reverse osmosis module cleaning, sanitizing and filter replacement procedure 7 recommendations have all components on hand and ready before beginning procedure a clean work area and equipment are essential to properly clean and/or disinfect the system (i.E., clean hands, too...

  • Page 12

    Mechanical filtration or reverse osmosis module cleaning, sanitizing and filter replacement procedure 8 13. Slowly open source water supply valve. 14. Open outlet valve. Close valve as soon as water begins to flow from port. 15. Wait 5 minutes, then close source water supply valve. 16. Wait 25 minut...

  • Page 13

    Atmospheric product water storage tank cleaning and sanitizing procedure 9 recommendations have all components on hand and ready before beginning procedure a clean work area and equipment are essential to properly clean and/or disinfect the system (i.E., clean hands, tools, work surface, and contain...

  • Page 14

    Ultraviolet module installation and connection procedure 10 warning: never look directly at a lighted uv lamp. Ultraviolet rays can be harmful to eyes. Never install system upstream from pump. Assembly is required before connection. Follow instructions carefully! Ultraviolet lamp module note: all it...

  • Page 15

    Ultraviolet module installation and connection procedure 11 item description part no. Item description part no. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 sump, ultraviolet lamp or filter cartridge “o” ring, sump activated carbon filter, 0.5 micron epcb activated carbon filter, 10 micron sleeve, quar...

  • Page 16

    Ultraviolet module installation and connection procedure 12 aquasafe™ ultraviolet and mechanical filtration system 2 module unit, 4.5 or 8.5 gpm with sediment filter and uv lamp aquasafe™ ultraviolet system 1 module unit, 4.5 or 8.5 gpm with uv lamp and stainless steel sleeve aquasafe™ ultraviolet a...

  • Page 17

    Ultraviolet module operational requirements 13 it is important that any water treatment system be properly maintained to ensure consistent water quality. Information provided on this page is of a general nature. For more detailed information, refer to the cleaning, disinfecting, and filter replaceme...

  • Page 18

    Ultraviolet module cleaning, sanitizing, and cartridge replacement procedure 14 recommendations have all components on hand and ready before beginning procedure a clean work area and equipment are essential to properly clean and/or disinfect the system (i.E., clean hands, tools, work surface, and co...

  • Page 19

    Ultraviolet module cleaning, sanitizing, and cartridge replacement procedure 15 3. Caution: use care when sanitizing uv head. Do not get the uv control module or connectors wet. Caution: tighten sumps by hand only. Do not use tools as they will over-tighten and may damage sump. Take care not to cut ...

  • Page 20

    © 2005 watergroup inc. Manufactured at 2375 sanders rd., northbrook, il 60062 form ogas-04 05.05 p/n 36101272 limited warranty subject to the conditions and limitations described below, watergroup, warrants its aquasafe™ reverse osmosis, mechanical filtration, and ultraviolet drinking water treatmen...