WaterLogic WL Max Technical Manual

Summary of WL Max

  • Page 1

    Wl max technical manual - version 1 - may 2013 wl max technical manual.

  • Page 2

    2 3 wl max technical manual - version 1 - may 2013 index machine overview 4 flow diagram 8 pre delivery inspection procedures (pdi) 11 installation procedures 12 installation kit 14 operating instructions 15 maintenance and servicing 16 sanitizing 18 fault finding 20 technical specifications and war...

  • Page 3: Machine Overview

    4 5 wl max technical manual - version 1 - may 2013 5 machine overview wl max ice bank technology the ice bank technology system is manufactured from 304 stainless steel which is non-corrosive and inert. The cold water temperature is preset at the factory at approximately 5 degrees c, this being the ...

  • Page 4

    6 7 wl max technical manual - version 1 - may 2013 uv lamp the uv light is a 13 watt germicidal lamp at a wavelength of 253.7 nm, which is very efficient at destroying bacteria in water. The uv lamp is situated in the firewall chamber surrounded by a quartz spiral that attains nsf standard 55 purifi...

  • Page 5: Flow Diagram

    8 9 wl max technical manual - version 1 - may 2013 flow diagram single faucet flow diagram double faucet drain valve fil ter in (water) cold water out filter dryer ice bank compressor condenser cold sensor solenoid valve drain valve fil ter in (water) cold water out filter dryer ice bank compressor ...

  • Page 6: Pre Delivery

    10 11 wl max technical manual - version 1 - may 2013 pre delivery inspection procedures (pdi) caution: only competent trained technicians should work on waterlogic products. Waterlogic units may weigh over 25kg. We recommend caution when lifting. Packing materials could present a trip hazard. Keep t...

  • Page 7: Installation Procedures

    12 13 wl max technical manual - version 1 - may 2013 installation procedures 1. Mount the wl max on a firm, level surface so the machine cannot topple or fall over. A 50mm air gap is required the whole way around the machine to allow for sufficient ventilation. The wl max must not be installed in di...

  • Page 8: Operating Instructions

    14 15 wl max technical manual - version 1 - may 2013 installation kit the wl max must be installed according to the local guidelines and a pressure reducer must be installed as part of the installation. The pressure reducer should not be set higher than 3bar. • the wl max should not be connected to ...

  • Page 9: Maintenance And Servicing

    16 17 wl max technical manual - version 1 - may 2013 maintenance and servicing • every six months or every 6 000 uv lamp cycles we strongly recommended that the uv lamp be changed. • every six months or after 10 000 litres it is strongly recommended that the filter be changed. • the firewall quartz ...

  • Page 10

    18 19 wl max technical manual - version 1 - may 2013 sanitising 1. Put on the rubber gloves to minimise the chance of any contamination to the machine and to protect yourself whilst the servicing procedure is being carried out. 2. You will need to stop the water supply to the machine by turning the ...

  • Page 11

    20 21 wl max technical manual - version 1 - may 2013 fault finding all fault finding procedures must be carried by a technician trained by waterlogic international or their nominated distributor. Please take great care and suitable health and safety measures when fault finding on live electrical par...

  • Page 12: Technical Specifications

    22 23 wl max technical manual - version 1 - may 2013 technical specifications and warranties safety subject to the standard terms and conditions of sale (a copy of which has been provided to you), neither waterlogic international limited (“waterlogic”), nor any affiliated companies shall be liable f...

  • Page 13: End of Life

    24 25 wl max technical manual - version 1 - may 2013 end of life non eu countries at the end of this products life, please ensure that it is disposed of in an environmentally friendly manner which is in line with your country requirements/ guidelines. Weee (eu only) please be aware that our products...

  • Page 14

    26 27 wl max technical manual - version 1 - may 2013 electrical wiring diagram 230v danger high voltages present on this pcb care must be taken when live testing.

  • Page 15: Wetted Parts Illustration

    28 29 wl max technical manual - version 1 - may 2013 wetted parts illustration single faucet 1 7 7 7 8 9 1 3 1 2 4 6 5 n° part no. Part description 1 pu-4031 jg 1/4" pe pipe 2 pu-4028 jg bulkhead connector union 1/4" * 1/4" 3 pu-4031 jg 1/4" pe pipe 4 ft-0034 10" inline cbc filter 1 micron 5 pu-4008...

  • Page 16: Wetted Parts Illustration

    30 31 wl max technical manual - version 1 - may 2013 wetted parts illustration double faucet 1 5 7 8 7 8 7 10 7 9 1 3 1 2 5 4 n° part no. Part description 1 pu-4031 jg 1/4" pe pipe 2 pu-4028 jg bulkhead connector union 1/4" * 1/4" 3 pu-4031 jg 1/4" pe pipe 4 ft-0034 10" inline cbc filter 1 micron 5 ...

  • Page 17: Main Parts List

    32 33 wl max technical manual - version 1 - may 2013 n° part description 1 front panel 2 drip tray grill 3 drain valve 4 band 1 switches band 2 switches 5 3 position switch 6 upper panel 7 firewall housing top cover 8 uv rubber mount 9 uv sensor rubber mount 10 uv sensor 11 15w uv lamp 12 jg 1/4" el...

  • Page 18

    34 35 wl max technical manual - version 1 - may 2013 n° part description 26 emi filter 27 electrical panel cover 28 electrical case 29 power cord 30 inline cbc filter 31 jg 1/4" bulkhead connector 32 filter clip 33 jg 1/4" elbow 34 jg 1/4" straight connector 35 drain hose 36 reservoir tank lid 37 pu...

  • Page 19

    36 eng0332-28/06/13 wli trading ltd. Suite 4, 2nd floor beacon court, sandyford, dublin 18, ireland www.Waterlogic.Com waterlogic usa, 4141 n. 156th street, omaha, ne 68116 speak to a water expert rest of the world exportsales@waterlogic.Com + 353 1 293 1960 usa, canada and mexico info@waterlogicusa...