Air to water split type design & technical manual comfort series ( single phase type ) innovative solution of domestic heating dtw_1sp003e_02.
Contents single phase type : woa060ldc, woa080ldc, woa100ldt outdoor 11 unit single phase type: wsa050dd6, wsa100dd6 hydraulic 21 unit wsa050dd6, wsa100dd6 (hydraulic unit) control system 31.
Combinations 11 class outdoor unit hydraulic unit 5.0 kw woa060ldc wsa050dd6 6.0 kw woa060ldc wsa100dd6 8.0 kw woa080ldc wsa100dd6 10.0 kw woa100ldt wsa100dd6.
1. Outdoor unit dtw_1sp003e_02--chapter01 2013.2.28 single phase type : woa060ldc woa080ldc woa100ldt.
O u td o o r u n it wo a 060 -1 00 ld o u td o o r u n it wo a 060 -1 00 ld contents outdoor 11 unit 11 features 11111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111ou01 - 01 21 specifications 1111111111111111111111111111111111111111111111...
- (ou01 - 01) - outdoor unit / single phase o u td o o r u n it wo a 060 -1 00 ld o u td o o r u n it wo a 060 -1 00 ld features 11 models : woa060ldc woa080ldc woa100ldt high performance high efficiency & comfort z high cop 08 split type model allows flexible installations. Hydraulic unit emitte...
- (ou01 - 02) - outdoor unit / single phase o u td o o r u n it wo a 060 -1 00 ld o u td o o r u n it wo a 060 -1 00 ld high leaving water temperature maximum leaving water temperature is 55°c without backup heater. Hot water supply temperature can be maintained even at –7°c outdoor temperature. Wid...
- (ou01 - 03) - outdoor unit / single phase o u td o o r u n it wo a 060 -1 00 ld o u td o o r u n it wo a 060 -1 00 ld wide comfort wide comfort by the clean energy produced by reliably delivers “comfort” to diverse spaces in the home up to the living room, bedrooms, bath and swimming pool. Radiato...
- (ou01 - 04) - outdoor unit / single phase o u td o o r u n it wo a 060 -1 00 ld o u td o o r u n it wo a 060 -1 00 ld specifications 21 nominal capacity and nominal input 2-11 model name (outdoor unit) woa060ldc woa080ldc woa100ldt power source 1Ø 230v/50hz +7°c/+35°c floor heating heating capa...
- (ou01 - 05) - outdoor unit / single phase o u td o o r u n it wo a 060 -1 00 ld o u td o o r u n it wo a 060 -1 00 ld technical specifications 2-21 model name (outdoor unit) woa060ldc woa080ldc woa100ldt enclosure colour beige apporoximate colour of munsell 10yr 7.5/1.0 material steel sheet dim...
- (ou01 - 06) - outdoor unit / single phase o u td o o r u n it wo a 060 -1 00 ld o u td o o r u n it wo a 060 -1 00 ld electrical specifications 2-31 model name (outdoor unit) woa060ldc woa080ldc woa100ldt available voltage range 198-264v power supply voltage v 230 frequency hz 50 *1) max. Opera...
- (ou01 - 07) - outdoor unit / single phase o u td o o r u n it wo a 060 -1 00 ld o u td o o r u n it wo a 060 -1 00 ld dimensions 31 dimensional drawing 3-11 models : wo a060l, woa080l (unit : mm) 540 320 4holes Ø11 drain hole bottom view.
- (ou01 - 08) - outdoor unit / single phase o u td o o r u n it wo a 060 -1 00 ld o u td o o r u n it wo a 060 -1 00 ld models : wo a100l (unit : mm).
- (ou01 - 09) - outdoor unit / single phase o u td o o r u n it wo a 060 -1 00 ld o u td o o r u n it wo a 060 -1 00 ld installation place 3-21 models : wo a060l, woa080l (unit: mm) 300 or more 300 or more models : wo a100l.
- (ou01 - 10) - outdoor unit / single phase o u td o o r u n it wo a 060 -1 00 ld o u td o o r u n it wo a 060 -1 00 ld piping diagram 41 models : wo a060l, woa080l heating emitter (floor heating, radiator) dedicated compressor for injection port mounting compressor temperature sensor indoor unit h...
- (ou01 - 11) - outdoor unit / single phase o u td o o r u n it wo a 060 -1 00 ld o u td o o r u n it wo a 060 -1 00 ld wiring diagram 51 wiring diagram 5-11 models : wo a060l.
- (ou01 - 12) - outdoor unit / single phase o u td o o r u n it wo a 060 -1 00 ld o u td o o r u n it wo a 060 -1 00 ld models : wo a080l.
- (ou01 - 13) - outdoor unit / single phase o u td o o r u n it wo a 060 -1 00 ld o u td o o r u n it wo a 060 -1 00 ld models : wo a100l.
- (ou01 - 14) - outdoor unit / single phase o u td o o r u n it wo a 060 -1 00 ld o u td o o r u n it wo a 060 -1 00 ld capacity tables 61 heating capacity 6-11 model : woa060l (4.5kw type) ft : flow temperature ot : outdoor temperature hc : heating capacity (kw) ip : input power (kw) cop : coeffic...
- (ou01 - 15) - outdoor unit / single phase o u td o o r u n it wo a 060 -1 00 ld o u td o o r u n it wo a 060 -1 00 ld model : woa060l (6.0kw type) ft : flow temperature ot : outdoor temperature hc : heating capacity (kw) ip : input power (kw) cop : coefficient of performance the values of heating...
- (ou01 - 16) - outdoor unit / single phase o u td o o r u n it wo a 060 -1 00 ld o u td o o r u n it wo a 060 -1 00 ld model : woa080l ft 30°c 35°c 40°c 45°c 50°c 55°c ot hc ip cop hc ip cop hc ip cop hc ip cop hc ip cop hc ip cop -20°c 4.49 2.03 2.21 4.26 2.13 2.00 4.03 2.21 1.82 ― ― ― ― ― ― ― ― ...
- (ou01 - 17) - outdoor unit / single phase o u td o o r u n it wo a 060 -1 00 ld o u td o o r u n it wo a 060 -1 00 ld model : woa100l ft 30°c 35°c 40°c 45°c 50°c 55°c ot hc ip cop hc ip cop hc ip cop hc ip cop hc ip cop hc ip cop -20°c 5.97 2.57 2.32 5.89 2.86 2.06 5.60 3.05 1.84 ― ― ― ― ― ― ― ― ...
- (ou01 - 18) - outdoor unit / single phase o u td o o r u n it wo a 060 -1 00 ld o u td o o r u n it wo a 060 -1 00 ld cooling capacity 6-21 * model : woa060l (4.5kw type) * : optional parts “cooling kit" is necessary for cooling operation. Ft : flow temperature ot : outdoor temperature cc : cooli...
- (ou01 - 19) - outdoor unit / single phase o u td o o r u n it wo a 060 -1 00 ld o u td o o r u n it wo a 060 -1 00 ld model : woa060l (6.0kw type) * : optional parts “cooling kit" is necessary for cooling operation. Ft : flow temperature ot : outdoor temperature cc : cooling capacity (kw) ip : in...
- (ou01 - 20) - outdoor unit / single phase o u td o o r u n it wo a 060 -1 00 ld o u td o o r u n it wo a 060 -1 00 ld model : woa080l * : optional parts “cooling kit" is necessary for cooling operation. Ft : flow temperature ot : outdoor temperature cc : cooling capacity (kw) ip : input power (kw...
- (ou01 - 21) - outdoor unit / single phase o u td o o r u n it wo a 060 -1 00 ld o u td o o r u n it wo a 060 -1 00 ld model : woa100l * : optional parts “cooling kit" is necessary for cooling operation. Ft : flow temperature ot : outdoor temperature cc : cooling capacity (kw) ip : input power (kw...
- (ou01 - 22) - outdoor unit / single phase o u td o o r u n it wo a 060 -1 00 ld o u td o o r u n it wo a 060 -1 00 ld operation noise 71 noise level curve 7-11 o ct av e b an d s ou nd p re ss ur e l ev el , d b: (0 db =0 .0 00 2µ ba r) o ct av e b an d s ou nd p re ss ur e l ev el , d b: (0 db =0...
- (ou01 - 23) - outdoor unit / single phase o u td o o r u n it wo a 060 -1 00 ld o u td o o r u n it wo a 060 -1 00 ld sound level check point 7-21.
- (ou01 - 24) - outdoor unit / single phase o u td o o r u n it wo a 060 -1 00 ld o u td o o r u n it wo a 060 -1 00 ld operation range 81 coolin g mode flow temperature (°c) flow temperature (°c) heatin g mode sanitary mode outdoor temperature (°cdb) 43 8 6 35 35 0 -20 -7 8 55 outdoor temperature (...
- (ou01 - 25) - outdoor unit / single phase o u td o o r u n it wo a 060 -1 00 ld o u td o o r u n it wo a 060 -1 00 ld safety devices 91 protection from model woa060ldc woa080ldc woa100ldt circuit protection current fuse (near the terminal) 250v 20a 250v 25a 250v 25a current fuse (main pcb) 250v...
- (ou01 - 26) - outdoor unit / single phase o u td o o r u n it wo a 060 -1 00 ld o u td o o r u n it wo a 060 -1 00 ld standard accessories 101 name and shape q'ty application installation manual 1 drain pipe 1 for outdoor unit drain piping work (for woa100ldt) drain cap 2 insulation (seal) 1 for ...
2. Hydraulic unit dtw_1sp003e_02--chapter02 2013.03.22 single phase type : wsa050dd6 wsa100dd6.
H yd r a u li c u n it ws a 05 0- 10 0d d 6 h yd r a u li c u n it ws a 05 0- 10 0d d 6 contents hydraulic 22 unit 12 features 222222222222222222222222222222222222222222222222222222222222222222222222222222222222222222222222222222222222222222 iu01 - 01 22 specifications 222222222222222222222222222222...
- (hu01 - 01) - hydraulic unit / single phase h yd r a u li c u n it ws a 05 0- 10 0d d 6 h yd r a u li c u n it ws a 05 0- 10 0d d 6 features 12 model : wsa050dd6 wsa100dd6 intelligent control 2-zone individual control * z hydraulic unit outdoor unit pump pump valve *: optional parts are required...
- (hu01 - 02) - hydraulic unit / single phase h yd r a u li c u n it ws a 05 0- 10 0d d 6 h yd r a u li c u n it ws a 05 0- 10 0d d 6 others automatic heating curve control z automatic temperature regulation in accordance with heating curve (depend on heating terminal and outdoor temperature) coolin...
- (hu01 - 03) - hydraulic unit / single phase h yd r a u li c u n it ws a 05 0- 10 0d d 6 h yd r a u li c u n it ws a 05 0- 10 0d d 6 specifications 22 technical specifications 2-12 model name (hydraulic unit) wsÛa050dd6 wsÛa100dd6 model name (outdoor unit) woÛa060ldc woÛa060ldc woÛa080ldc woÛa100ld...
- (hu01 - 04) - hydraulic unit / single phase h yd r a u li c u n it ws a 05 0- 10 0d d 6 h yd r a u li c u n it ws a 05 0- 10 0d d 6 electrical specifications 2-22 model name (hydraulic unit) wsÛa050dd6 wsÛa100dd6 model name (outdoor unit) woÛa060ldc woÛa060ldc woÛa080ldc woÛa100ldt electric heater...
- (hu01 - 05) - hydraulic unit / single phase h yd r a u li c u n it ws a 05 0- 10 0d d 6 h yd r a u li c u n it ws a 05 0- 10 0d d 6 dimensions 32 dimensional drawing 3-12 model : wsa050dd6, wsa100dd6 (unit : mm) 450 800 832,8 97 98 457 81 479 heating return ø m 26x34 heating flow ø m 26x34 front...
- (hu01 - 06) - hydraulic unit / single phase h yd r a u li c u n it ws a 05 0- 10 0d d 6 h yd r a u li c u n it ws a 05 0- 10 0d d 6 installation place 3-22 350 mm or more 1000 mm 300 mm or more installation precautions the room in which the appliance operates must comply with the prevailing regula...
- (hu01 - 07) - hydraulic unit / single phase h yd r a u li c u n it ws a 05 0- 10 0d d 6 h yd r a u li c u n it ws a 05 0- 10 0d d 6 piping diagram 42 model : wsa050dd6, wsa100dd6 electric heater buffer tank refrigerant water heat exchanger manometer safety valve water return sensor hot water hea...
- (hu01 - 08) - hydraulic unit / single phase h yd r a u li c u n it ws a 05 0- 10 0d d 6 h yd r a u li c u n it ws a 05 0- 10 0d d 6 wiring diagram 52 wiring diagram 5-12 model : wsa050dd6, wsa100dd6 c.C 0/i 2a 1a 1b 2b ex1 ex2 ex3 l n 1 2 3 4 5 l n com l l n x10 x11 x12 x13 x14 x15 x30 x50 x70 x...
- (hu01 - 09) - hydraulic unit / single phase h yd r a u li c u n it ws a 05 0- 10 0d d 6 h yd r a u li c u n it ws a 05 0- 10 0d d 6 external connection diagram 5-22 model : wsa050dd6, wsa100dd6 ex1 ex2 ex3 x60 x86 l x84 x11 2 1 3 m b9 b2 m b1 3 2 1 1 2 1 3 2 b2 m b1 outdoor sensor room thermosta...
- (hu01 - 10) - hydraulic unit / single phase h yd r a u li c u n it ws a 05 0- 10 0d d 6 h yd r a u li c u n it ws a 05 0- 10 0d d 6 hydraulic performance 62 static pressure drop unit 6-12 variable pressure 1mbar = 10 mmce = 100 pa 0 100 200 300 400 500 600 mbar m /h 3 1 1.5 2 2.5 0.5 0 2 4 66 ext....
- (hu01 - 11) - hydraulic unit / single phase h yd r a u li c u n it ws a 05 0- 10 0d d 6 h yd r a u li c u n it ws a 05 0- 10 0d d 6 safety devices 72 protection form model wsÛa050dd6 wsÛa100dd6 circuit protection current fuse (main pcb) 20 a high pressure protection safety valve 3 bar or more.
- (hu01 - 12) - hydraulic unit / single phase h yd r a u li c u n it ws a 05 0- 10 0d d 6 h yd r a u li c u n it ws a 05 0- 10 0d d 6 standard accessories 82 name and shape q'ty application installation and operating manual 1 operation manual 5 outdoor sensor 1 to monitor the outdoor temperature bra...
3. Control system dtw_1sp003e_02--chapter03 2013.03.22 wsa050dd6 (hydraulic unit) wsa100dd6 (hydraulic unit).
C o n tr o l sy st em c o n tr o l sy st em contents control system 33 13 features ………………………………………………………………………………… cs01 - 01 23 functions ……………………………………………………………………………… cs01 - 03 2-13 user interface and remote control (optional parts) …………… cs01 - 03 2-23 room thermostat (optional parts) ……………………………...
- (cs01 - 01) - control system c o n tr o l sy st em c o n tr o l sy st em features 13 smart & comfort control the outdoor temperature is detected by sensor and the heating water temperature is controlled automatically. The setting of room temperature and operation mode can be easily set. A wide ran...
- (cs01 - 02) - control system - (cs01 - 02) - c o n tr o l sy st em c o n tr o l sy st em extendibility z diverse operation control meets diverse needs by combining with optional parts. Options 2-temperature simultaneous heating floor heating + radiator heating (split type only) operation together ...
- (cs01 - 03) - control system c o n tr o l sy st em c o n tr o l sy st em functions 23 user interface 2-13 and remote control (optional parts) auto esc ok 0 4 8 12 16 20 24 1 2 3 4 5 1 2 3 4 6 5 7 12 8 6 7 8 9 ref 3 functions - definitions 1 selecting dhw operating mode (domestic hot water) on off ...
- (cs01 - 04) - control system - (cs01 - 04) - c o n tr o l sy st em c o n tr o l sy st em ref 3 functions - definitions 6 information display various data. - designation line floor drying current setpoint - current drying day - terminated drying days - state heat pump 8006 state supplementary sourc...
- (cs01 - 05) - control system - (cs01 - 05) - c o n tr o l sy st em c o n tr o l sy st em ref 3 functions - definitions - reading error codes hydraulic unit : fault visible on the digital display. Error number error contents error location heat pump operation despite the error - no connection failu...
- (cs01 - 06) - control system - (cs01 - 06) - c o n tr o l sy st em c o n tr o l sy st em ref 3 functions - definitions 7 confirm "ok" input into the selected menu. - confirmation of the parameter settings. - confirmation of the adjustment to the comfort temp. Setting. - 8 selecting cooling mode if...
- (cs01 - 07) - control system - (cs01 - 07) - c o n tr o l sy st em c o n tr o l sy st em room thermostat (optional parts) 2-23 °c auto 5 10 11 12 ref 3 functions - definitions 5 selecting heating mode auto - heating operating according to the heating program (summer/winter mode switchover is autom...
- (cs01 - 08) - control system - (cs01 - 08) - c o n tr o l sy st em c o n tr o l sy st em control setting 2-33 general the settings described below are those which can be modified by the user. We wish to remind you that changing the settings below may cause the heat pump to behave in an undesirable...
- (cs01 - 09) - control system - (cs01 - 09) - c o n tr o l sy st em c o n tr o l sy st em function table line access level function setting range or display factory setting time of day and date 1 u hours/minutes 00:00…23:59 2 u day/month 01.01…31.12 3 u year 1900…2099 5 s start of summertime 01.01…...
- (cs01 - 10) - control system - (cs01 - 10) - c o n tr o l sy st em c o n tr o l sy st em line access level function setting range or display factory setting time program 4 / dhw 560 u preselection mo-su / mo-fr / sa - su / mo / tu / we / th / fr / sa / su mo-su 561 u 1 st phase on 00:00…23:50, --:...
- (cs01 - 11) - control system - (cs01 - 11) - c o n tr o l sy st em c o n tr o l sy st em line access level function setting range or display factory setting 760 s room temp limitation 0.5…4°c 0.5°c 780 s quick setback off down to reduced setpoint down to frost prot setpoint down to reduced setpoin...
- (cs01 - 12) - control system - (cs01 - 12) - c o n tr o l sy st em c o n tr o l sy st em line access level function setting range or display factory setting heating circuit 2 1010 u comfort setpoint reduced temp to 35.0°c 20.0°c 1012 u reduced setpoint 19.0°c 1014 u frost protection setpoint 4°c t...
- (cs01 - 13) - control system - (cs01 - 13) - c o n tr o l sy st em c o n tr o l sy st em line access level function setting range or display factory setting swimming pool 2056 u setpoint source heating 8.0…80.0°c 22.0°c heat pump 2803 s overrun time cond pump 0…240s 240s 2843 s compressor off time...
- (cs01 - 14) - control system - (cs01 - 14) - c o n tr o l sy st em c o n tr o l sy st em line access level function setting range or display factory setting configuration 5700 i pre-setting ---, 1…12 1 5710 i heating circuit 1 off / on on 5711 i cooling circuit 1 off 4-pipe system 2-pipe system of...
- (cs01 - 15) - control system - (cs01 - 15) - c o n tr o l sy st em c o n tr o l sy st em line access level function setting range or display factory setting service / special operation 7070 s hp interval ---, 1..240 months ---months 7071 s hp time since maintenance 0...240months 0months reset? Yes...
- (cs01 - 16) - control system - (cs01 - 16) - c o n tr o l sy st em c o n tr o l sy st em line access level function setting range or display factory setting 7978 i sensor temp bx36 -28…350°c ---°c 7996 i contact state h33 open/closed open state of plant 8000 i state heating circuit 1 --- 8001 i st...
- (cs01 - 17) - control system - (cs01 - 17) - c o n tr o l sy st em c o n tr o l sy st em line access level function setting range or display factory setting 8740 u room temp 1 0.0…50.0°c --- room setpoint 1 4.0…35.0°c 20.0°c 8743 u flow temp 1 0.0…140.0°c --- flow temp setpoint 1 0.0…140.0°c --- 8...
- (cs01 - 18) - control system - (cs01 - 18) - c o n tr o l sy st em c o n tr o l sy st em description of abbreviations : hc = heating circuit ot = outside temperature hp = heat pump dhw = domestic hot water bxx, exx, qxx, dox, uxx, hx = terminal number *1: " outside temperature attenuated " is calc...
- (cs01 - 19) - control system - (cs01 - 19) - c o n tr o l sy st em c o n tr o l sy st em adjustment function details time of day and date functions z the controller has an annual clock which contains the time, the day of the week and the date. In order for the function to operate, the time and dat...
- (cs01 - 20) - control system - (cs01 - 20) - c o n tr o l sy st em c o n tr o l sy st em operator section functions z line function 20 language 22 info 26 operation lock 27 programming lock 28 direct adjustment 29 temperature unit pressure unit info temporarily • after pressing the info key, the i...
- (cs01 - 21) - control system - (cs01 - 21) - c o n tr o l sy st em c o n tr o l sy st em time program functions (heating circuit 1 & 2, dhw, cooling) z several control programs are available for the heating circuits and the production of dhw. They are initiated in "automatic" mode and control the ...
- (cs01 - 22) - control system - (cs01 - 22) - c o n tr o l sy st em c o n tr o l sy st em heating circuit 1 & 2 functions z operating mode for heating circuits there are several functions available which can be individually adjusted for each heating circuit. The programming lines for the 2nd heatin...
- (cs01 - 23) - control system - (cs01 - 23) - c o n tr o l sy st em c o n tr o l sy st em heating curve slope based on the heating characteristic, the controller computes the flow temperature setpoint which will be used for controlling the flow temperature in consideration of atmospheric conditions...
- (cs01 - 24) - control system - (cs01 - 24) - c o n tr o l sy st em c o n tr o l sy st em eco functions line function hc1 hc2 730 1030 summer/winter heating limit summer/winter heating limit the summer/winter heating limit switches the heating on or off through the year according to the temperature...
- (cs01 - 25) - control system - (cs01 - 25) - c o n tr o l sy st em c o n tr o l sy st em room influence line function hc1 hc2 750 1050 room influence control types: when using a room temperature sensor there are 3 different types of control to choose from. Setting control type - - - % simple contr...
- (cs01 - 26) - control system - (cs01 - 26) - c o n tr o l sy st em c o n tr o l sy st em quick setback line function 760 1060 room temp limitation 780 1080 quick setback room temp limitaion the "room temperature limitation" function enables the heating circuit pump to be deactivated should the roo...
- (cs01 - 27) - control system - (cs01 - 27) - c o n tr o l sy st em c o n tr o l sy st em reduced setpoint increase line function hc1 hc2 800 1100 reduced setpoint increase start 801 1101 reduced setpoint increase end this function is used mainly in heating installations that do not have high suppl...
- (cs01 - 28) - control system - (cs01 - 28) - c o n tr o l sy st em c o n tr o l sy st em floor curing function off • the function is deactivated. Heating operational (fh) • the first part of the temperature profile is automatically completed. Heating "ready for occupancy" (bh) • the second part of...
- (cs01 - 29) - control system - (cs01 - 29) - c o n tr o l sy st em c o n tr o l sy st em heating circuit frost protection informations: the heating circuit frost protection is continuously activated (protection mode ) and is not adjustable. Heating circuit frost protection in heating mode: - if th...
- (cs01 - 30) - control system - (cs01 - 30) - c o n tr o l sy st em c o n tr o l sy st em cooling circuit 1 functions z the cooling sequence is automatically started when the room temperature is higher than the comfort setpoint in cooling mode (line 902). The cooling function must be activated (lin...
- (cs01 - 31) - control system - (cs01 - 31) - c o n tr o l sy st em c o n tr o l sy st em cooling characteristic line function 908 flow temp setpoint at ot 25°c 909 flow temp setpoint at ot 35°c the controller computes the flow temperature required for a given composite outdoor temperature based on...
- (cs01 - 32) - control system - (cs01 - 32) - c o n tr o l sy st em c o n tr o l sy st em cooling limit at ot if the composite outdoor temperature is higher than the cooling limit, cooling is released. If the composite outdoor temperature falls at least 0.5°c below the cooling limit, cooling is loc...
- (cs01 - 33) - control system - (cs01 - 33) - c o n tr o l sy st em c o n tr o l sy st em flow setpoint limitation line function 923 flow temp setpoint min at ot 25°c 924 flow temp setpoint min at ot 35°c it is possible to assign a lower limit to the cooling flow temperature. The limitation line wi...
- (cs01 - 34) - control system - (cs01 - 34) - c o n tr o l sy st em c o n tr o l sy st em control according to outdoor conditions with room influence the difference between the room temperature and the setpoint value is measured and taken into account for temperature control. This enables taking in...
- (cs01 - 35) - control system - (cs01 - 35) - c o n tr o l sy st em c o n tr o l sy st em mixing valve control line function 938 mixing valve decrease 941 actuator running time 945 mixing valve heating mode mixing valve decrease the cooling demand issued by cooling circuit 1 to production is reduce...
- (cs01 - 36) - control system - (cs01 - 36) - c o n tr o l sy st em c o n tr o l sy st em domestic hot water functions z the control sets the dhw temperature, according to the time program or continuously, to the desired setpoint. The priority of dhw charging over room heating is adjustable in this...
- (cs01 - 37) - control system - (cs01 - 37) - c o n tr o l sy st em c o n tr o l sy st em release line function 1620 release of dhw load (24h/day / heating circ time pgm / time program 4/dhw / low-tariff/ time pgm 4/dhw or low-tariff) 24h/day (not recommended) regardless of the time programs, the t...
- (cs01 - 38) - control system - (cs01 - 38) - c o n tr o l sy st em c o n tr o l sy st em dhw mode holiday status release (line 1620) time program status (program 4) low- tariff status (ex2) dhw mode level off x x x x frost protection on yes x x x frost protection on no … … x … on no low-tariff (op...
- (cs01 - 39) - control system - (cs01 - 39) - c o n tr o l sy st em c o n tr o l sy st em swimming pool functions z line function 2056 setpoint source heating the controller enables a swimming pool to be heated by the heat pump. An individual setpoint can be set by means of line 2056, which appears...
- (cs01 - 40) - control system - (cs01 - 40) - c o n tr o l sy st em c o n tr o l sy st em heat pump functions z line function 2803 overrun time cond pump 2843 compressor off time min 2844 switch-off temp max 2862 locking time stage 2 2873 compressor mod run time 2882 release integral electric flow ...
- (cs01 - 41) - control system - (cs01 - 41) - c o n tr o l sy st em c o n tr o l sy st em compensation heat deficit this function compensates for excess heat and heatdeficits. These can occur in the following situations: minimum compressor on and off times in the case of low temperature requests, t...
- (cs01 - 42) - control system - (cs01 - 42) - c o n tr o l sy st em c o n tr o l sy st em supplementary source z a supplementary producer can be operated in addition to the main producer (heat pump). Release of the supplementary producer depends on a number of parameters a detailed description of w...
- (cs01 - 43) - control system - (cs01 - 43) - c o n tr o l sy st em c o n tr o l sy st em locking time the locking time enables the heat pump to reach a stable operating state before the supplementary source is allowed to switch on. The supplementary source is released only when the locking time ha...
- (cs01 - 44) - control system - (cs01 - 44) - c o n tr o l sy st em c o n tr o l sy st em dhw storage tank functions z dhw charging at the nominal setpoint temperature (line 1610) always takes place in two stages. In the first stage, only the heating pump heats the dhw tank. The power supplied duri...
- (cs01 - 45) - control system - (cs01 - 45) - c o n tr o l sy st em c o n tr o l sy st em heater line function 5061 electric immersion heater release electric immersion heater release 24h/day • the heater is continuously active regardless of time programs. 0 6 12 18 24 h dhw release • the heater is...
- (cs01 - 46) - control system - (cs01 - 46) - c o n tr o l sy st em c o n tr o l sy st em configuration functions z when an installation is started up, the indoor unit diagram presetting for that installation must be entered. Pre-settings line function 5700 pre-setting only pre-setting 1 to 4 are u...
- (cs01 - 47) - control system - (cs01 - 47) - c o n tr o l sy st em c o n tr o l sy st em basic unit ex/e line function 5981 5983 5985 contact type input ex1, ex2, ex3 the type of contact can be selected: nc the input’s function is active when voltage is not present. No the input’s function is acti...
- (cs01 - 48) - control system - (cs01 - 48) - c o n tr o l sy st em c o n tr o l sy st em reset to default parameters all parameters can be reset to factory settings, except followings: time and date, user interface, and all time programs, as well as the operating hours and the various counters. So...
- (cs01 - 49) - control system - (cs01 - 49) - c o n tr o l sy st em c o n tr o l sy st em table of error messages which can be displayed: no3 designation of error location reset hp operation priority manual automatic 0: no fault 10: outdoor sensor bx4 (x84) no no yes 6 30: flow sensor 1 bx1 (x80) n...
- (cs01 - 50) - control system - (cs01 - 50) - c o n tr o l sy st em c o n tr o l sy st em no3 designation of error location reset hp operation priority manual automatic 359: no cooling valve y21 no no yes 3 360: no process reversing valve y22 no no yes 3 364: heat pump cooling system error no no ye...
- (cs01 - 51) - control system - (cs01 - 51) - c o n tr o l sy st em c o n tr o l sy st em service / special operation functions z maintenance maintenance functions can be used as a preventive step for periodically monitoring the installation. All maintenance functions can be individually activated ...
- (cs01 - 52) - control system - (cs01 - 52) - c o n tr o l sy st em c o n tr o l sy st em simulation line function 7150 simulation outside temp simulation outside temp to make the starting-up and troubleshooting processes easier, it is possible to simulate an outdoor temperature in the range of -50...
- (cs01 - 53) - control system - (cs01 - 53) - c o n tr o l sy st em c o n tr o l sy st em input / output test functions z input/output testing is used to ensure that the connected components are in working order. Relay output testing selection of a setting from relay testing closes the correspondin...
- (cs01 - 54) - control system - (cs01 - 54) - c o n tr o l sy st em c o n tr o l sy st em input test ex1-3 line function 7911 input ex1 7912 input ex2 7913 input ex3 by selecting a setting from input test ex1-3, the relevant input will be displayed, enabling it to be checked. Display of 0 v means t...
- (cs01 - 55) - control system - (cs01 - 55) - c o n tr o l sy st em c o n tr o l sy st em state functions z the current operating status of the installation can be viewed by means of status displays. Messages line function 8000 state heating circuit 1 8001 state heating circuit 2 8003 state dhw 800...
- (cs01 - 56) - control system - (cs01 - 56) - c o n tr o l sy st em c o n tr o l sy st em state dhw (8003) end user (info level) commissioning, engineer thermostat response thermostat response manual action active manual action active draw-off mode draw-off mode adiabatic cooling active adiabatic c...
- (cs01 - 57) - control system - (cs01 - 57) - c o n tr o l sy st em c o n tr o l sy st em state cooling circuit 1 (8004) end user (info level) commissioning, engineer dewpoint sensor activated dewpoint sensor activated manual action active manual action active fault fault frost protection active fl...
- (cs01 - 58) - control system - (cs01 - 58) - c o n tr o l sy st em c o n tr o l sy st em state heat pump (8006) end user (info level) commissioning, engineer emergency mode emergency mode fault fault locked locked, outdoor temperature locked, external locked, economy mode lim. Time active consumer...
- (cs01 - 59) - control system - (cs01 - 59) - c o n tr o l sy st em c o n tr o l sy st em state supplementary source (8022) end user (info level) commissioning, engineer locked locked, solid fuel boiler locked, outside temperature locked, economy mode in operation for hc, dhw in operation for hc, d...
- (cs01 - 60) - control system - (cs01 - 60) - c o n tr o l sy st em c o n tr o l sy st em diagnostics heat generation functions z various setpoints and actual values, relay switch status data can be displayed for purposes of diagnosis. Heat pump line function 8402 electric immersion heater 1 flow 8...
- (cs01 - 61) - control system - (cs01 - 61) - c o n tr o l sy st em c o n tr o l sy st em diagnostics consumers functions z various setpoints and actual values, relay switch status and timing status data can be displayed for purposes of diagnosis. Outside temperatures line function 8700 outside tem...
- (cs01 - 62) - control system - (cs01 - 62) - c o n tr o l sy st em c o n tr o l sy st em domestic hot water line function 8820 dhw pump 8821 dhw electrical resistance 8830 dhw temperature 8840 hours run dhw pump 8841 start counter dhw pump 8842 hours run electric dhw 8843 start counter electric dh...
- (cs01 - 63) - control system - (cs01 - 63) - c o n tr o l sy st em c o n tr o l sy st em status of relays for extension modules 1 and 2 line function 9050 relay output qx21 module 1 9051 relay output qx22 module 1 9052 relay output qx23 module 1 9053 relay output qx21 module 2 9054 relay output qx...
- (cs01 - 64) - control system c o n tr o l sy st em c o n tr o l sy st em electrical connections 33 overview of all the electrical connections 3-13 the wiring diagram for the indoor unit is shown in detail on electrical wiring diagrams (chapter 1 for outdoor unit and chapter 2 for indoor unit). Or ...
- (cs01 - 65) - control system - (cs01 - 65) - c o n tr o l sy st em c o n tr o l sy st em electrical connections on the hydraulic unit 3-23 remove the front panel (2 screws a) • 1 a 1 a 2 removing the front panel remove the cover of the electric box (1 screw b) • b 3 4 access to hydraulic unit elec...
- (cs01 - 66) - control system - (cs01 - 66) - c o n tr o l sy st em c o n tr o l sy st em make the connections in accordance with the diagram(s)3 • do not place the sensor lines and the sector supply lines in parallel in order to avoid causing inadvertent interference due to voltage points in the s...
- (cs01 - 67) - control system - (cs01 - 67) - c o n tr o l sy st em c o n tr o l sy st em interconnection between the outdoor • unit and the indoor unit comply with the correspondence between the markings on the indoor unit’s terminals and those on the outdoor unit when connecting the interconnecti...
- (cs01 - 68) - control system - (cs01 - 68) - c o n tr o l sy st em c o n tr o l sy st em connections to the heat pump regulator 3-33 (accessories and options) single phase model c.C 0/i 2a 1a 1b 2b ex1 ex2 ex3 l n 1 2 3 4 5 l n com l l n x10 x11 x12 x13 x14 x15 x30 x50 x70 x75 x80 x82 x83 x84 x86 ...
- (cs01 - 69) - control system - (cs01 - 69) - c o n tr o l sy st em c o n tr o l sy st em single phase x10 x11 x12 x13 x14 x15 x30 x50 x70 x75 x80 x82 x83 x84 x86 x100 x60 connections to the heat pump regulator (a cc es so rie s an d op tio ns ) d3 d2 d1 ux3 m di6 di7 m b x 1 m b x 2 ux1 m l e arth...
- (cs01 - 70) - control system - (cs01 - 70) - c o n tr o l sy st em c o n tr o l sy st em connection terminals heat pump regulator rvs213827 z low voltage main voltage terminal use terminal use x75 m gnd (common with interface pcb) x10 l power supply di7 hp error earth di6 defrost n uref compressor...
- (cs01 - 71) - control system - (cs01 - 71) - c o n tr o l sy st em c o n tr o l sy st em outdoor sensor the outdoor sensor is required for the heat pump to operate correctly. Consult the fitting instructions on the sensor’s packaging. Place the sensor on the coldest part, generally the northern or...
- (cs01 - 72) - control system - (cs01 - 72) - c o n tr o l sy st em c o n tr o l sy st em start-up make sure that all dip sw on the interface card are off before starting up. Dip sw shuold be set off - for normal operation. Power supply to the indoor unit must be turned off while toching dip sw. Cl...
- (cs01 - 73) - control system - (cs01 - 73) - c o n tr o l sy st em c o n tr o l sy st em in the case of 2 heating circuits choose the allocation of the remote control unit (room appliance 1 or 2…) line 40*. - according to the allocation selected check and, if necessary, modify the settings for lin...
- (cs01 - 74) - control system c o n tr o l sy st em c o n tr o l sy st em installation 43 outdoor sensor 4-13 model : qac34 24.5 25 8.6 5.5 6 9.6 installation z h (1/2 h ) m in imu m 2. 5 m field supply.
- (cs01 - 75) - control system c o n tr o l sy st em c o n tr o l sy st em remote control (optional parts) 4-23 model : utw-c75xa the remote control includes the functions of the room unit together with those of the user interface mounted in series on the indoor unit. It can be used, therefore, not ...
- (cs01 - 76) - control system - (cs01 - 76) - c o n tr o l sy st em c o n tr o l sy st em connections z the remote control must be connected to the connector x86 (terminal 1, 2, 3) of the heat pump controller board. To do this, you can use a 0.5mm² cable of the two- pair telephone cable type. If th...
- (cs01 - 77) - control system c o n tr o l sy st em c o n tr o l sy st em model : utw-c78xd (wireless) the remote control includes the functions of the room unit together with those of the user interface mounted in series on the indoor unit. It can be used, therefore, not only to measure the room t...
- (cs01 - 78) - control system - (cs01 - 78) - c o n tr o l sy st em c o n tr o l sy st em.
- (cs01 - 79) - control system - (cs01 - 79) - c o n tr o l sy st em c o n tr o l sy st em room thermostat (optional parts) 4-33 model : utw-c55xa the room thermostat is optional. Select an appropriate place for the room thermostat by following these rules: central room ● installation height, approx...
- (cs01 - 80) - control system - (cs01 - 80) - c o n tr o l sy st em c o n tr o l sy st em model : utw-c58xd (wireless) the room thermostat is optional. Select an appropriate place for the room thermostat by following these rules: central room ● installation height, approx. 1.5 m ● inner wall ● away...
- (cs01 - 81) - control system - (cs01 - 81) - c o n tr o l sy st em c o n tr o l sy st em rf module (optional parts) 4-43 model : utw-m60xd, utw-mrcxd the wireless components should be located such that transmission is as interference-free as possible. ● the following criteria must be observed: not...
- (cs01 - 82) - control system c o n tr o l sy st em c o n tr o l sy st em dimensions 53 outdoor sensor 5-13 model : qac34 79.8 91.6 49.7 24.5 25 8.6 5.5 6 9.6 front view side view rear view top view bottom view (unit : mm).
- (cs01 - 83) - control system c o n tr o l sy st em c o n tr o l sy st em remote control (optional parts) 5-23 model : utw-c75xa / utw-c78xd (wireless) controller z front view side view rear view top view 159 82 37 holder z front view side view rear view bottom view 32.5 80 56 60 100 9 11 39 67 4.2...
- (cs01 - 84) - control system - (cs01 - 84) - c o n tr o l sy st em c o n tr o l sy st em room thermostat (optional parts) 5-33 model : utw-c55xa / utw-c58xd (wireless) unit z front view side view rear view bottom view top view 96 47 4.2 56 60 56 60 96 (unit : mm).
- (cs01 - 85) - control system - (cs01 - 85) - c o n tr o l sy st em c o n tr o l sy st em rf module (optional parts) 5-43 model : utw-m60xd 66.5 55.8 43 71 28.8 front view side view bottom view (unit : mm).
- (cs01 - 86) - control system - (cs01 - 86) - c o n tr o l sy st em c o n tr o l sy st em model : utw-mrcxd front view side view rear view 96 96 40 4.2 56 60 56 91 96 60 (unit : mm).
- (cs01 - 87) - control system c o n tr o l sy st em c o n tr o l sy st em packing list (accessories) 63 remote control (optional parts) 6-13 model : utw-c75xa* / utw-c78xd (wireless) name and shape quantity application remote control 1 use for atw operation remote control holder 1 use as remote con...
- (cs01 - 88) - control system c o n tr o l sy st em c o n tr o l sy st em rf module (optional parts) 6-33 model : utw-m60xd name and shape quantity application rf module 1 operating instructions 1 model : utw-mrcxd name and shape quantity application rf module 1 operating instructions 1.
- (cs01 - 89) - control system c o n tr o l sy st em c o n tr o l sy st em wiring specifications 73 outdoor sensor 7-13 model : qac34 use size wire type remarks outdoor sensor cable 0.75 mm² 2 wires connection max. Cable length: 60 m use shielded (field supplied) in accordance with the regional cabl...
- (cs01 - 90) - control system c o n tr o l sy st em c o n tr o l sy st em specifications 83 outdoor sensor 8-13 model : qac34 size ( h x w x d mm ) 91.6 x 79.8 x 49.7 weight ( g ) 73 cable length ( m ) 60 remote control (optional parts) 8-23 model : utw-c75xa size ( h x w x d mm ) 185 x 82 x 42 wei...
- (cs01 - 91) - control system c o n tr o l sy st em c o n tr o l sy st em rf module (optional parts) 8-43 model : utw-m60xd size ( h x w x d mm ) 67 x 71 x 56 weight ( g ) 54 cable length ( m ) 1.5 power ( v ) 5.5 frequency band (mhz) 868 model : utw-mrcxd size ( h x w x d mm ) 96 x 96 x 40 weight ...
Distributed by : iso 9001 certified number:09 100 89394 fujitsu general ( thailand ) co., ltd. Iso 14001 certified number:09 104 9245 1116, suenaga, takatsu-ku, kawasaki 213-8502, japan http://www.Fujitsu-general.Com/ " " is a worldwide trademark of fujitsu general limited. Copyright© 2009-2013 fuji...