WaterStep M-100 Instruction Manual - Shutting Down The M-100
1
2
Loosen and remove the plug at the top of the fill tube on the CHLORINE side. Keep
your face away from the fill tube and
DO NOT INHALE THE CHLORINE GAS!
Insert the (red) drain tube at the bottom of the
Chlorine side of the M-100 into the top of the
empty container labled
CHLORINE. Release
the pinch clamp and let all the chlorine pour
into the container. Keep your face away from
the opening of the empty container and
DO
NOT INHALE THE CHLORINE GAS!
NOTE: Sodium Hydroxide will vary in strength
depending on how often you REUSE the
Sodium Hydroxide from previous chlorination
batches. Sodium Hydroxide will get stronger
and stronger with each use.
DO NOT ALLOW MORE THAN THREE
CHLORINATION PROCESSES WITH THE
SAME BATCH OF SODIUM HYDROXIDE. IT
WILL GET VERY STRONG AND WILL BURN
YOUR SKIN IF SPILLED.
SHUTTING DOWN THE M-100
Continued
Before the M-100 is completely shut down and stored, have two empty containers - each of
which will hold up to two liters of liquid. Use a permanent marker to write
CHLORINE on one
container and
SODIUM HYDROXIDE on the other container. Please write POISON - DO NOT
DRINK on each bottle as well. DO NOT USE SODA BOTTLES...EVER!
CHLORINE
POISON - DO NOT DRINK
16