Waterwise 4000 User Manual - page 10
10
Waterwise Model 4000 Distiller Use & Care Guide
Cleaning Collection/Storage Bottle
See page 5 for cleaning and sanitizing instructions.
Replacing
Carbon
Filter
See page 6 for preparation and installation instructions.
TROUBLESHOOTING
1.
Not
making
distilled
water.
A.
Power
cord
not
plugged
in.
B. No electricity at outlet.
C. Fan cord not plugged into fan cord receptacle.
D.
Reset
button
not
pressed.
E. No water in boiler tank.
2. Not making enough water each cycle.
A. Fan cord not plugged into fan cord receptacle.
B. Boiler tank not fi lled to “FULL” line.
C. Collection/storage bottle not placed directly under fi lter cup.
D. Cover gasket not sealing properly or needs to be replaced.
E.
Condenser
fi ns dirty (fi g. F).
F. Ambient conditions such as room temperature and humidity.
See Important Safeguards, page 3, number 11.
3. Steam coming from fi lter cup.
A. Fan cord not plugged into fan cord receptacle.
B.
Condenser
fi ns dirty (fi g. F).
4.
Water
leaks
from
unit.
A. Filter cup not properly fastened under spout (fi g. C).
B. Cover gasket not sealing properly or needs to be replaced.
C. Protective seals on fi lter cup have not been removed.
IMPORTANT: There are NO user serviceable parts inside Distiller.
Removal of the base plate may void warranty. Contact qualifi ed service
personnel for repair if the above troubleshooting tips fail.
WARNING: Always be sure to unplug power cord from electrical outlet
before cleaning or servicing Distiller.