Watlow Electric EM00-GATE-0000 User Manual

Other manuals for EM00-GATE-0000: Specification Sheet

Summary of EM00-GATE-0000

  • Page 1

    Em gateway user’s manual for watlow part number em00-gate-0000 1241 bundy boulevard, p.O. Box 5580, winona, minnesota usa 55987-5580 phone: +1 (507) 454-5300, fax: +1 (507) 452-4507, internet: http://www.Watlow.Com 0600-0040-0001 rev d $10.00 february 2004.

  • Page 2

    2 em gateway table of contents chapter 1: product overview 4 ethernet gateway 4 ethernet gateway architecture 4 program upgrades 5 chapter 2: installation and wiring 6 dimensions 7 chapter 3: configuration 8 getting started 8 network services 8 email alarm notification 8 data logging 9 control monit...

  • Page 3

    3 em gateway table of contents – cont. Chapter 6: reference documents 25 reference documents 25 serial numbers 25 chapter 7: specifications 26 power supply 26 environmental 26 indication 26 agency 26 communications 26 control output signals 26 enclosure size 26 user interface 26 ordering information...

  • Page 4

    4 chapter one product overview the em00-gate-0000 is a gateway / bridge that allows up to 32 watlow controllers to be directly connected to an ethernet network. Using an http browser such as microsoft internet explorer or netscape navigator you may access 16 controllers and view several controllers’...

  • Page 5

    5 program upgrades the gateway has a tftp server for the purposes of reprogramming the program memory. A program update will be initiated when a tftp client, residing on a pc, begins to write a new program file to the gateway tftp server. When reprogramming the program memory, all other gateway serv...

  • Page 6

    6 chapter two installation & wiring ul approved, class 2 power supply required.

  • Page 7

    7 dimensions are in inches.

  • Page 8

    8 chapter three configuration getting started perform these steps; 1. Connect the em00-gate-0000 gateway to your computer’s ethernet port using a cross-wired rj45 cable or connect the em00-gate-0000 to a hub or network using a straight wired rj45 category 5 cable. The em00-gate-0000 is limited to a ...

  • Page 9

    9 you will need to configure your gateway with your smtp server name or address. A dns server address must also be configured if using a smtp name. Contact your system administrator if you don’t know the smtp name or address. Data logging the gateway provides no explicit means of data logging. Data ...

  • Page 10

    10 chapter four html pages the section describes the pages available from the em gateway’s web server. When the web page is first accessed, you are prompted for a user name and password. The default user name is ‘new’. The default password is ‘user’. These are case sensitive. The user name and passw...

  • Page 11

    11 use this page to disable or enable automatic page refreshing or to change the time in between refreshes. In addition, you can force a rescan of the modbus network. This will cause the gateway to detect any new devices added to the serial network. Set the baud rate of the network to 9600 or 19200-...

  • Page 12

    12 use this page to change the gateway identification name or to change the ip address resolution method. Contact your is administrator for questions regarding these settings..

  • Page 13

    13 use this page to enable notification and configure the addresses for email recipients. These recipients will receive an email when an alarm occurs on any controller. Contact your is administrator for questions regarding these settings..

  • Page 14

    14 use this page to update the time and date stored in the gateway. This information is used to identify the time and date of alarms when emails are sent..

  • Page 15

    15 1 0 0 0 0 1174 0 2 0 0 0 0 1174 0 3 0 0 0 0 1174 0 4 0 0 0 0 1174 0 5 0 0 0 0 1174 0 6 0 0 0 0 1174 0 7 0 0 0 0 1174 0 8 0 0 0 0 1174 0 9 0 0 0 0 1174 0 10 0 0 0 0 1174 0 11 5 2 0 3 1167 0 12 0 0 0 0 1174 0 13 0 0 0 0 1174 0 14 0 0 0 0 1174 0 15 0 0 0 0 1174 0 16 0 0 0 0 1174 0 the serial statist...

  • Page 16

    16 this page was loaded wed feb 1318: 00:28 2002 ip address 7.3.37.91 subnet 255.255.224.0 gateway 7.3.63.250 mac address 00:03:aa:00:00:c1 receives 128349 unicasts 1207 multicasts 0 broadcasts 127061 rx errors 0 rx missed 2089 rx crc errors 28 rx drops 0 transmits 1251 buffer defers 0 tx errors 0 t...

  • Page 17

    17 chapter five controller parameters and registers the em gateway supports the following parameters for each type of controller when using an http browser: series 96 – non-ramping operation mode – register 200 with choice of auto or manual as read only input error – register 101 with choice of sens...

  • Page 18

    18 series 988 / 989 operation mode – register 10 with choice of auto or manual as read only input error – register 4 with choice of sensor error or ok as read only process value input 1 – register 1 as read only process value input 2 – register 2 as read only auto set point – register 7 as read/writ...

  • Page 19

    19 series f4p operation mode – register 200 with choice of auto or manual as read only input 1 error – register 101 with choice of sensor error or ok as read only input 2 error – register 105 with choice of sensor error or ok as read only input 3 error – register 109 with choice of sensor error or o...

  • Page 20

    20 cls200 series (loop 1 to 16 if available) operation mode – register 264 to 279 with choice of auto or manual as read only input error – registers 660 to 675 with choice of ok, tc reversed, tc short, tc open, rtd open, or rtd short as read only process value – registers 363 to 378 as read only aut...

  • Page 21

    21.

  • Page 22

    22.

  • Page 23

    23.

  • Page 24

    24.

  • Page 25

    25 chapter six reference documents the modbus rtu specification is located at: http://www.Modicon.Com/techpubs/toc7.Html or http://www.Modbus.Org serial numbers gateways are labeled with a unique serial number in numeric and bar code formats. The serial number is embedded in the gateway firmware. Em...

  • Page 26

    26 chapter seven specifications power supply • voltage input 24 v (ac/dc) +10%, -15% 50/60 hz +/- 5 • connection through 2-position removable screw style terminal block • 22 to 12 awg • power consumption 10 va max • ul approved, class 2 power supply required • real-time clock backed by 3v-lithium ba...

  • Page 27

    27 declaration of conformity gateway products watlow winona, inc. 1241 bundy blvd. Winona, mn 55987 usa declares that the following product: model numbers: em00-gate-0000, ngw0-0000-2400 and ngw0-0000-0000* classification: communications interface card, installation category i, pollution degree ii r...

  • Page 28

    28 how to reach us technical assistance if you encounter a problem with your em gateway, review all of your wiring and configuration information to verify that your selections are consistent with your application. If the problem persists after checking the above, you can get technical assistance fro...